VRL7E Type AC RCBO

The VIOX VRL7E is an electronic Type AC RCBO for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N design combines residual-current, overload and short-circuit protection with 2-40 A ratings, B or C tripping characteristics and 10, 30 or 100 mA sensitivities. It provides a 4.5 kA short-circuit capacity and mounts on a standard 35 mm DIN rail.

Rated Current
2-40 A
Residual Current
10, 30, 100 mA
Pole Configuration
1P+N
Breaking Capacity
4.5 kA

Overview

The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.

Features

  • Electronic Type AC residual-current detection.
  • Residual-current, overload and short-circuit protection.
  • 1P+N configuration for AC 230 V circuits.
  • B and C thermomagnetic release characteristics.
  • 4.5 kA rated short-circuit capacity.
  • Integrated fault-current indicator.
  • 35 mm DIN-rail mounting with a fast-clip device.

Specifications

Electrical Data

ParameterSpecification
Operating ModeElectronic type
Rated Current2, 4, 6, 10, 16, 20, 25, 32, 40 A
Pole Configuration1P+N
Rated Operational Voltage230 V AC
Rated Frequency50/60 Hz
Rated Insulation Voltage250 V
Rated Impulse Withstand Voltage4 kV, 1.2/50 μs
Dielectric Test Voltage2 kV for 1 minute

Protection Data

ParameterSpecification
Residual-Current TypeType AC
Thermomagnetic Release CharacteristicB, C
Rated Residual Operating Current10, 30, 100 mA
Rated Residual Making and Breaking Capacity500 A
Rated Short-Circuit Capacity4.5 kA
Break Time at IΔn≤ 0.1 s
Pollution Degree2

Mechanical and Installation Data

ParameterSpecification
Electrical Life4,000 operations
Mechanical Life10,000 operations
Fault-Current IndicatorYes
Degree of ProtectionIP20
Terminal ConnectionCable / pin-type busbar / U-type busbar
Cable Terminal Capacity25 mm², AWG 18-5, top/bottom
Busbar Terminal Capacity25 mm², AWG 18-3, top/bottom
Mounting35 mm DIN rail to EN 60715; fast-clip device
Supply ConnectionFrom top

Environmental Data

ParameterSpecification
Ambient Temperature-5 °C to +40 °C; daily average ≤ 35 °C
Storage Temperature-25 °C to +70 °C

Standard

ParameterSpecification
StandardIEC/EN 61009-1

Selection Guide

Code ElementMeaningAvailable Values
VVIOX enterprise identificationV
RLRCBO product familyRL
7EDesign series7E
CurveOvercurrent tripping curveB or C
CurrentRated current2-40 A
SensitivityRated residual operating current10, 30 or 100 mA
PolesOrdering designation2P in the catalog example
Example ModelConfiguration
VRL7E-B16-10B curve, 16 A, 10 mA
VRL7E-C20-30C curve, 20 A, 30 mA
VRL7E-C40-100C curve, 40 A, 100 mA

Tripping Curve

Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.

Rated Current

Select one of the listed ratings from 2 A to 40 A.

Residual Sensitivity

Select a rated residual operating current of 10, 30 or 100 mA.

Circuit Configuration

The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.

Trip Curves

The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.

Protection CharacteristicAvailable Option
Thermomagnetic ReleaseB or C curve
Residual-Current Break Time≤ 0.1 s at IΔn

Dimensions

VRL7E Type AC RCBO dimensional drawing
VRL7E Type AC RCBO dimensional drawing.

Applications

  • Residential final distribution boards.
  • Commercial final distribution circuits.
  • Light industrial distribution boards.
  • AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.

Installation

  • Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
  • Connect the supply from the top.
  • Use cable, pin-type busbar or U-type busbar connections as specified.
  • Observe the stated 25 mm² terminal capacity for cable and busbar connections.
  • Install within the specified ambient temperature range of -5 °C to +40 °C.

FAQ

What residual-current type does the VRL7E use?

It uses electronic Type AC detection for sinusoidal alternating residual currents.

What rated currents are available?

The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.

Which residual-current sensitivities are available?

The available rated residual operating currents are 10, 30 and 100 mA.

What is the VRL7E short-circuit capacity?

The rated short-circuit capacity is 4.5 kA.

How is the VRL7E installed?

It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.

Need a Product Quote?
Let’s Build It Together.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Request a Quote