VIOXエレクトリック
Language

VRL7E Type AC RCBO

The VIOX VRL7E is an electronic Type AC RCBO for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N design combines residual-current, overload and short-circuit protection with 2-40 A ratings, B or C tripping characteristics and 10, 30 or 100 mA sensitivities. It provides a 4.5 kA short-circuit capacity and mounts on a standard 35 mm DIN rail.

定格電流
2-40 A
漏電電流
10, 30, 100 mA
ポール構成
1P+N
遮断容量
4.5kA

概要

The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.

特徴

  • Electronic Type AC residual-current detection.
  • Residual-current, overload and short-circuit protection.
  • 1P+N configuration for AC 230 V circuits.
  • B and C thermomagnetic release characteristics.
  • 4.5 kA rated short-circuit capacity.
  • 統合型故障電流表示器。.
  • 35 mm DIN-rail mounting with a fast-clip device.

仕様

電気的データ

パラメータ仕様
Operating ModeElectronic type
定格電流2, 4, 6, 10, 16, 20, 25, 32, 40 A
ポール構成1P+N
定格動作電圧230 V AC
定格周波数50/60 Hz
定格絶縁電圧250 V
定格インパルス耐電圧4 kV, 1.2/50 μs
絶縁耐力試験電圧2 kV、1分間

保護データ

パラメータ仕様
Residual-Current TypeタイプAC
Thermomagnetic Release CharacteristicB、C
定格残留動作電流10, 30, 100 mA
定格残留短絡遮断容量500 A
Rated Short-Circuit Capacity4.5kA
Break Time at IΔn≤ 0.1 s
汚染度2

機械的および設置データ

パラメータ仕様
電気的寿命4,000回
機械的寿命10,000回
Fault-Current Indicatorあり
保護等級IP20
Terminal ConnectionCable / pin-type busbar / U-type busbar
Cable Terminal Capacity25 mm², AWG 18-5, top/bottom
Busbar Terminal Capacity25 mm², AWG 18-3, top/bottom
取り付け35 mm DIN rail to EN 60715; fast-clip device
Supply ConnectionFrom top

Environmental Data

パラメータ仕様
周囲温度-5 °C to +40 °C; daily average ≤ 35 °C
保存温度-25 °C to +70 °C

標準

パラメータ仕様
標準IEC/EN 61009-1

セレクションガイド

コード要素意味利用可能な値
VVIOX企業識別V
RLRCBO製品ファミリーRL
7E設計シリーズ7E
特性曲線過電流トリップ曲線BまたはC
現在定格電流2-40 A
感度定格感度電流10, 30 or 100 mA
ポールOrdering designation2P in the catalog example
Example Model構成
VRL7E-B16-10B curve, 16 A, 10 mA
VRL7E-C20-30C curve, 20 A, 30 mA
VRL7E-C40-100C curve, 40 A, 100 mA

トリッピングカーブ

Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.

定格電流

Select one of the listed ratings from 2 A to 40 A.

残留感度

Select a rated residual operating current of 10, 30 or 100 mA.

回路構成

The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.

トリップカーブ

The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.

Protection CharacteristicAvailable Option
Thermomagnetic ReleaseB or C curve
Residual-Current Break Time≤ 0.1 s at IΔn

寸法

VRL7E Type AC RCBO dimensional drawing
VRL7E Type AC RCBO dimensional drawing.

アプリケーション

  • Residential final distribution boards.
  • Commercial final distribution circuits.
  • Light industrial distribution boards.
  • AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.

インストール

  • Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
  • Connect the supply from the top.
  • Use cable, pin-type busbar or U-type busbar connections as specified.
  • Observe the stated 25 mm² terminal capacity for cable and busbar connections.
  • Install within the specified ambient temperature range of -5 °C to +40 °C.

よくあるご質問

What residual-current type does the VRL7E use?

It uses electronic Type AC detection for sinusoidal alternating residual currents.

利用可能な定格電流はいくつですか?

The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.

Which residual-current sensitivities are available?

The available rated residual operating currents are 10, 30 and 100 mA.

What is the VRL7E short-circuit capacity?

The rated short-circuit capacity is 4.5 kA.

How is the VRL7E installed?

It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.

製品の見積もりが必要ですか?
私たちと一緒に作り上げましょう。.

製品モデル、技術定格、数量、およびOEM要件をお送りください。当社のチームがお客様の用途を確認し、1営業日以内に回答いたします。.

見積依頼