Visión general
The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.
Características
- Electronic Type AC residual-current detection.
- Residual-current, overload and short-circuit protection.
- 1P+N configuration for AC 230 V circuits.
- B and C thermomagnetic release characteristics.
- 4.5 kA rated short-circuit capacity.
- Indicador de corriente de falla integrado.
- 35 mm DIN-rail mounting with a fast-clip device.
Especificaciones
Datos eléctricos
| Parámetro | Especificación |
|---|---|
| Operating Mode | Electronic type |
| Corriente Nominal | 2, 4, 6, 10, 16, 20, 25, 32, 40 A |
| Configuración de postes | 1P+N |
| Tensión nominal de funcionamiento | 230 V AC |
| Frecuencia nominal | 50/60 Hz |
| Tensión nominal de aislamiento | 250 V |
| Tensión nominal soportada al impulso | 4 kV, 1.2/50 μs |
| Voltaje de prueba dieléctrica | 2 kV durante 1 minuto |
Datos de protección
| Parámetro | Especificación |
|---|---|
| Residual-Current Type | Tipo AC |
| Thermomagnetic Release Characteristic | B, C |
| Corriente residual de funcionamiento nominal | 10, 30, 100 mA |
| Capacidad nominal de cierre y corte de corriente residual | 500 A |
| Rated Short-Circuit Capacity | 4.5 kA |
| Break Time at IΔn | ≤ 0.1 s |
| Grado de contaminación | 2 |
Datos mecánicos y de instalación
| Parámetro | Especificación |
|---|---|
| Vida eléctrica | 4.000 operaciones |
| Vida mecánica | 10,000 operaciones |
| Fault-Current Indicator | Sí |
| Grado de protección | IP20 |
| Terminal Connection | Cable / pin-type busbar / U-type busbar |
| Cable Terminal Capacity | 25 mm², AWG 18-5, top/bottom |
| Busbar Terminal Capacity | 25 mm², AWG 18-3, top/bottom |
| Montaje | 35 mm DIN rail to EN 60715; fast-clip device |
| Supply Connection | From top |
Environmental Data
| Parámetro | Especificación |
|---|---|
| Temperatura ambiente | -5 °C to +40 °C; daily average ≤ 35 °C |
| Temperatura de almacenamiento | -25 °C to +70 °C |
Estándar
| Parámetro | Especificación |
|---|---|
| Estándar | IEC/EN 61009-1 |
Guía de selección
| Elemento de código | Significado | Valores disponibles |
|---|---|---|
| V | Identificación de empresa VIOX | V |
| RL | Familia de productos RCBO | RL |
| 7E | Serie de diseño | 7E |
| Curva | Curva de disparo por sobreintensidad | B o C |
| Actual | Corriente nominal | 2-40 A |
| Sensibilidad | Corriente residual de funcionamiento nominal | 10, 30 or 100 mA |
| Polos | Ordering designation | 2P in the catalog example |
| Example Model | Configuración |
|---|---|
| VRL7E-B16-10 | B curve, 16 A, 10 mA |
| VRL7E-C20-30 | C curve, 20 A, 30 mA |
| VRL7E-C40-100 | C curve, 40 A, 100 mA |
Curva de disparo
Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.
Corriente Nominal
Select one of the listed ratings from 2 A to 40 A.
Sensibilidad residual
Select a rated residual operating current of 10, 30 or 100 mA.
Configuración del circuito
The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.
Curvas de viaje
The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.
| Protection Characteristic | Available Option |
|---|---|
| Thermomagnetic Release | B or C curve |
| Residual-Current Break Time | ≤ 0.1 s at IΔn |
Dimensiones
Aplicaciones
- Residential final distribution boards.
- Commercial final distribution circuits.
- Light industrial distribution boards.
- AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.
Instalación
- Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
- Connect the supply from the top.
- Use cable, pin-type busbar or U-type busbar connections as specified.
- Observe the stated 25 mm² terminal capacity for cable and busbar connections.
- Install within the specified ambient temperature range of -5 °C to +40 °C.
PREGUNTAS FRECUENTES
What residual-current type does the VRL7E use?
It uses electronic Type AC detection for sinusoidal alternating residual currents.
¿Qué corrientes nominales In están disponibles?
The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.
Which residual-current sensitivities are available?
The available rated residual operating currents are 10, 30 and 100 mA.
What is the VRL7E short-circuit capacity?
The rated short-circuit capacity is 4.5 kA.
How is the VRL7E installed?
It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.