VIOX Elektrik
Language

VRL7E Tip AC RCBO

The VIOX VRL7E is an electronic Type AC RCBO for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N design combines residual-current, overload and short-circuit protection with 2-40 A ratings, B or C tripping characteristics and 10, 30 or 100 mA sensitivities. It provides a 4.5 kA short-circuit capacity and mounts on a standard 35 mm DIN rail.

Anma Akımı
2-40 A
Kaçak Akım
10, 30, 100 mA
Kutup Konfigürasyonu
1P+N
Kesme Kapasitesi
4.5 kA

Genel Bakış

The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.

Özellikler

  • Electronic Type AC residual-current detection.
  • Residual-current, overload and short-circuit protection.
  • 1P+N configuration for AC 230 V circuits.
  • B and C thermomagnetic release characteristics.
  • 4.5 kA rated short-circuit capacity.
  • Entegre hata akımı göstergesi.
  • 35 mm DIN-rail mounting with a fast-clip device.

Teknik Özellikler

Elektriksel Veriler

ParametreŞartname
Operating ModeElectronic type
Anma Akımı2, 4, 6, 10, 16, 20, 25, 32, 40 A
Kutup Konfigürasyonu1P+N
Nominal Çalışma Gerilimi230 V AC
Nominal Frekans50/60 Hz
Nominal İzolasyon Gerilimi250 V
Anma Darbe Dayanım Gerilimi4 kV, 1.2/50 μs
Dielektrik Test Voltajı1 dakika boyunca 2 kV

Koruma Verileri

ParametreŞartname
Artık Akım TipiTip AC
Thermomagnetic Release CharacteristicB, C
Anma Artık Çalışma Akımı10, 30, 100 mA
Nominal Artık Açma ve Kapama Kapasitesi500 A
Rated Short-Circuit Capacity4.5 kA
Break Time at IΔn≤ 0.1 s
Kirlilik Derecesi2

Mekanik ve Kurulum Verileri

ParametreŞartname
Elektriksel Yaşam4.000 operasyon
Mekanik Ömür10.000 işlem
Fault-Current IndicatorEvet
Koruma DerecesiIP20
Terminal ConnectionCable / pin-type busbar / U-type busbar
Cable Terminal Capacity25 mm², AWG 18-5, top/bottom
Busbar Terminal Capacity25 mm², AWG 18-3, top/bottom
Montaj35 mm DIN rail to EN 60715; fast-clip device
Supply ConnectionFrom top

Environmental Data

ParametreŞartname
Ortam Sıcaklığı-5 °C to +40 °C; daily average ≤ 35 °C
Depolama Sıcaklığı-25 °C to +70 °C

Standart

ParametreŞartname
StandartIEC/EN 61009-1

Seçim Rehberi

Kod ElemanıAnlamıMevcut Değerler
VVIOX işletme tanımlamasıV
RLRCBO ürün ailesiRL
7ETasarım serisi7E
EğriAşırı akım açma eğrisiB veya C
GüncelNominal akım2-40 A
HassasiyetAnma kaçak çalışma akımı10, 30 or 100 mA
KutuplarOrdering designation2P in the catalog example
Example ModelKonfigürasyon
VRL7E-B16-10B curve, 16 A, 10 mA
VRL7E-C20-30C curve, 20 A, 30 mA
VRL7E-C40-100C curve, 40 A, 100 mA

Gezinme Eğrisi

Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.

Anma Akımı

Select one of the listed ratings from 2 A to 40 A.

Artık Hassasiyet

Select a rated residual operating current of 10, 30 or 100 mA.

Devre Yapılandırması

The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.

Gezi Eğrileri

The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.

Protection CharacteristicAvailable Option
Thermomagnetic ReleaseB or C curve
Residual-Current Break Time≤ 0.1 s at IΔn

Boyutlar

VRL7E Type AC RCBO dimensional drawing
VRL7E Type AC RCBO dimensional drawing.

Uygulamalar

  • Residential final distribution boards.
  • Commercial final distribution circuits.
  • Light industrial distribution boards.
  • AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.

Kurulum

  • Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
  • Connect the supply from the top.
  • Use cable, pin-type busbar or U-type busbar connections as specified.
  • Observe the stated 25 mm² terminal capacity for cable and busbar connections.
  • Install within the specified ambient temperature range of -5 °C to +40 °C.

SSS

What residual-current type does the VRL7E use?

It uses electronic Type AC detection for sinusoidal alternating residual currents.

Hangi In değerleri mevcuttur?

The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.

Which residual-current sensitivities are available?

The available rated residual operating currents are 10, 30 and 100 mA.

What is the VRL7E short-circuit capacity?

The rated short-circuit capacity is 4.5 kA.

How is the VRL7E installed?

It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.

Ürün Teklifi mi İstiyorsunuz?
Birlikte İnşa Edelim.

Bize ürün modelini, teknik değerleri, miktarı ve OEM gereksinimlerini gönderin. Ekibimiz başvurunuzu inceleyecek ve bir iş günü içinde yanıt verecektir.

Teklif İsteyin