VIOX Electric
Language

VRL7E AC típusú RCBO

The VIOX VRL7E is an electronic Type AC RCBO for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N design combines residual-current, overload and short-circuit protection with 2-40 A ratings, B or C tripping characteristics and 10, 30 or 100 mA sensitivities. It provides a 4.5 kA short-circuit capacity and mounts on a standard 35 mm DIN rail.

Névleges áram
2-40 A
Maradékáram
10, 30, 100 mA
Póluskonfiguráció
1P+N
Törési kapacitás
4,5 kA

Áttekintés

The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.

Jellemzők

  • Electronic Type AC residual-current detection.
  • Residual-current, overload and short-circuit protection.
  • 1P+N configuration for AC 230 V circuits.
  • B and C thermomagnetic release characteristics.
  • 4.5 kA rated short-circuit capacity.
  • Integrált hibaáram-jelző.
  • 35 mm DIN-rail mounting with a fast-clip device.

Műszaki adatok

Elektromos adatok

ParaméterSpecifikáció
Operating ModeElectronic type
Névleges áram2, 4, 6, 10, 16, 20, 25, 32, 40 A
Póluskonfiguráció1P+N
Névleges üzemi feszültség230 V AC
Névleges frekvencia50/60 Hz
Névleges szigetelési feszültség250 V
Névleges lökésálló feszültség4 kV, 1,2/50 μs
Dielektromos tesztfeszültség2 kV, 1 percen keresztül

Védelmi adatok

ParaméterSpecifikáció
Residual-Current TypeAC típus
Thermomagnetic Release CharacteristicB, C
Névleges kioldó maradékáram10, 30, 100 mA
Névleges maradékáram-kapcsolóképesség500 A
Rated Short-Circuit Capacity4,5 kA
Break Time at IΔn≤ 0.1 s
Szennyezettségi fok2

Mechanikai és telepítési adatok

ParaméterSpecifikáció
Elektromos élet4000 kapcsolási ciklus
Mechanikai élettartam10 000 művelet
Fault-Current IndicatorIgen
Védelmi fokIP20
Terminal ConnectionCable / pin-type busbar / U-type busbar
Cable Terminal Capacity25 mm², AWG 18-5, top/bottom
Busbar Terminal Capacity25 mm², AWG 18-3, top/bottom
Szerelés35 mm DIN rail to EN 60715; fast-clip device
Supply ConnectionFrom top

Environmental Data

ParaméterSpecifikáció
Környezeti hőmérséklet-5 °C to +40 °C; daily average ≤ 35 °C
Tárolási hőmérséklet-25 °C to +70 °C

Standard

ParaméterSpecifikáció
StandardIEC/EN 61009-1

Kiválasztási útmutató

KódelemJelentéseElérhető értékek
VVIOX vállalati azonosítóV
RLRCBO termékcsaládRL
7ETervezési sorozat7E
KarakterisztikaTúláram kioldási görbeB vagy C
JelenlegiNévleges áram2-40 A
ÉrzékenységNévleges maradványáram10, 30 or 100 mA
LengyelekOrdering designation2P in the catalog example
Example ModelKonfiguráció
VRL7E-B16-10B curve, 16 A, 10 mA
VRL7E-C20-30C curve, 20 A, 30 mA
VRL7E-C40-100C curve, 40 A, 100 mA

Kioldási görbe

Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.

Névleges áram

Select one of the listed ratings from 2 A to 40 A.

Maradékáram-érzékenység

Select a rated residual operating current of 10, 30 or 100 mA.

Áramkör konfiguráció

The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.

Utazási görbék

The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.

Protection CharacteristicAvailable Option
Thermomagnetic ReleaseB or C curve
Residual-Current Break Time≤ 0.1 s at IΔn

Méretek

VRL7E Type AC RCBO dimensional drawing
VRL7E Type AC RCBO dimensional drawing.

Alkalmazások

  • Residential final distribution boards.
  • Commercial final distribution circuits.
  • Light industrial distribution boards.
  • AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.

Telepítés

  • Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
  • Connect the supply from the top.
  • Use cable, pin-type busbar or U-type busbar connections as specified.
  • Observe the stated 25 mm² terminal capacity for cable and busbar connections.
  • Install within the specified ambient temperature range of -5 °C to +40 °C.

GYIK

What residual-current type does the VRL7E use?

It uses electronic Type AC detection for sinusoidal alternating residual currents.

Milyen névleges áramerősségek (In) érhetők el?

The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.

Which residual-current sensitivities are available?

The available rated residual operating currents are 10, 30 and 100 mA.

What is the VRL7E short-circuit capacity?

The rated short-circuit capacity is 4.5 kA.

How is the VRL7E installed?

It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.

Termékajánlatot kérne?