Four protective functions in one final-circuit device.
The catalog combines arc-fault detection with three familiar circuit-protection functions. Each function addresses a different fault condition.
Arc-fault detection
Monitors current signatures associated with hazardous arcing conditions.
Type A residual current
Responds to sinusoidal AC and pulsating-DC residual-current conditions within the declared sensitivity.
Overload protection
Provides the published B or C overcurrent tripping characteristic for sustained overcurrent.
Short-circuit protection
Interrupts short-circuit current within the device’s declared 6kA rating.
Choose the VIOX AFDD version.
Both models share the published protection range. Select the construction version, then confirm the exact current, characteristic and residual-current sensitivity.
Compare VAF1-40 and VAF3-40M.
The electrical values below reproduce the shared VIOX catalog. The catalog identifies VAF3-40M as the magnetic version.
| Specification | VAF1-40 | VAF3-40M |
|---|---|---|
| Version | Integrated AFDD | Magnetic version |
| Product configuration | AFDD with integrated Type A residual-current, overload and short-circuit protection | |
| Applicable standards | IEC/EN 61009-1 · IEC/EN 62606 | |
| Rated voltage / frequency | 240V AC · 50Hz | |
| Rated current | 6, 10, 13, 16, 20, 25, 32, 40A | |
| Overcurrent characteristic | B / C | |
| Residual-current type / IΔn | Type A · 10mA / 30mA | |
| Poles / modular width | 1P+N · 1 module (as stated in the catalog) | |
| Rated short-circuit current | 6kA | |
| Uimp / Ui | 4kV / 250V | |
| Terminal capacity / torque | 1–25mm² / 2–2.4N·m | |
| Maximum connected cable length | 70m between the distribution board and the furthest socket outlet | |
Why arc faults require a dedicated detection function.
Some hazardous arcs may not create the high current expected from a conventional short circuit. An AFDD evaluates current behavior for arc signatures while the integrated overcurrent and residual-current functions continue to address their own fault categories.
Read the IEC 62606 guideTypical final-circuit applications.
Use the project design and applicable installation rules to determine where AFDD protection is required or appropriate.
Residential final circuits
Socket-outlet and other final circuits where combined arc-fault, residual-current and overcurrent protection is specified.
Commercial spaces
Offices, shops and similar installations with final circuits that require the declared combined protection functions.
Concealed wiring routes
Circuits where damaged conductors, loose connections or insulation deterioration can be difficult to inspect directly.
Fire-risk assessment
Projects where the electrical design identifies arc-fault mitigation as part of the fire-protection strategy.
4 Arc-Fault & Installation Failures Prevented
Standard MCBs and RCBOs leave a documented protection gap on high-impedance series arcs and low-level parallel arcs. VIOX VAF1-40 and VAF3-40M close that gap while preventing field nuisance trips.
Loose-Terminal Series Arc Ignition
A loose socket terminal, pinched flex cord, or corroded splice creates a series arc whose impedance limits current below In with zero earth leakage—leaving MCBs and RCBOs closed.
Line-to-Neutral Arc Below Magnetic Trip
Carbonized insulation between line and neutral causes intermittent parallel arcing below the 3–5×In (B) or 5–10×In (C) magnetic short-circuit threshold.
Nuisance Trips on Brushed & SMPS Loads
Vacuum cleaners, power tools, dimmers, and HF LED drivers generate benign switching spikes that trip poorly filtered arc detectors.
Long-Run Attenuation & Backup Fuse Limits
Oversized final-circuit cable runs dampen HF arc signals, while uncoordinated upstream fuses risk damage under high fault currents.
IEC 62606 & Wiring-Code Application Matrix
Map regulated building circuits directly to verified VIOX VAF1-40 and VAF3-40M ratings (240 V AC, 50 Hz, 6 kA, 1P+N 1-module). See our IEC 62606 guide and RCBO vs AFDD comparison.
| Circuit & Building Type | Primary Code Driver | Recommended VIOX Model | Rating & Curve | RCD & Installation Rule |
|---|---|---|---|---|
| High-Rise Residential Sleeping Rooms | BS 7671 Reg 421.1.7 / IEC 60364-4-42 | VAF1-40 / VAF3-40M | 16 A / 20 A / 32 A · B curve | Type A 30 mA · ≤ 70 m run · 100 A gG SCPD |
| HMOs & Student Accommodation | Mandatory socket-circuit AFDD rules | VAF3-40M (Magnetic) | 16 A / 20 A / 32 A · B curve | Type A 30 mA · Magnetic RCD · 1P+N |
| Care Homes & Assisted Living | High-risk sleeping accommodation | VAF3-40M (Magnetic) | 10 A / 16 A / 20 A · B curve | Type A 10 mA or 30 mA · 6 kA Icn |
| Timber-Frame & Heritage Buildings | IEC 60364-4-42 (CA2 combustible structures) | VAF1-40 / VAF3-40M | 6 A–32 A · B or C curve | Type A 30 mA · Top/bottom load feed |
| Commercial Socket & Office Circuits | DIN VDE 0100-420 / Fire-risk assessment | VAF1-40 | 16 A / 20 A / 25 A · C curve | Type A 30 mA · Handles SMPS inrush |
| Mixed-Load Panel Board Retrofits | 1-module DIN-rail space constraint | VAF1-40 / VAF3-40M | 6–40 A · B or C curve | 1P+N 1-module · L/R neutral · 2–2.4 N·m |
Build a complete AFDD order specification.
Do not select the device from “40A AFDD” alone. Confirm every rating and the destination-market document set.
Ask VIOX to review a specification- 01
Choose the model version
State VAF1-40 or the VAF3-40M magnetic version.
- 02
Confirm the current and curve
Select 6–40A and the required B or C characteristic for the circuit.
- 03
Confirm residual-current sensitivity
Specify the required Type A 10mA or 30mA configuration.
- 04
Verify installation conditions
Check voltage, frequency, prospective short-circuit current, conductors, torque and circuit length.
- 05
Request exact documents
Match the model, rating, destination market, labeling and required declarations before release.
IEC 62606 Market Tier Benchmarking
Objective engineering comparison across standard compliance, 4-in-1 footprint efficiency, residual-current mechanism, and factory-direct B2B supply.
| Evaluation Parameter | Global Tier-1 AFDD+RCBO Lines | Entry-Tier Electronic AFDD | VIOX VAF1-40 / VAF3-40M |
|---|---|---|---|
| Standards Compliance | IEC/EN 62606 + IEC/EN 61009-1 | IEC 62606 (often add-on block only) | IEC/EN 62606 + IEC/EN 61009-1 |
| Protection Integration | 4-in-1 (AFDD + Type A RCBO) | AFDD only (requires separate RCBO) | 4-in-1 Integrated (AFDD + Type A RCBO) |
| RCD Mechanism Options | Electronic or Magnetic by sub-series | Electronic-only | VAF1-40 + VAF3-40M (Magnetic Version) |
| Current, Curve & Breaking | 6–40 A · B/C · 6 kA or 10 kA | 6–32 A · C curve · 6 kA | 6–40 A · B/C · 10/30 mA · 6 kA |
| Wiring & Cable Run Spec | 1–16/25 mm² · 50–70 m run | Limited terminal & run specs | 1–25 mm² · 2–2.4 N·m · 70 m max · L/R Neutral |
| OEM & Distributor Margin | Fixed brand catalog; high unit cost | Inconsistent batch QC & docs | Factory-direct pricing + private-label OEM |
Direct Factory Engineering
Every VIOX VAF1-40 and VAF3-40M (Magnetic) is verified for 196–253 V test-circuit operation, Type A residual-current sensitivity, and 6 kA breaking coordination—ready for distributor stock, panel-builder schedules, and private-label OEM programs.
AFDD Ordering Code & B2B Procurement Guide
Decode exact catalog references for RFQs and consolidate AFDDs with VIOX MCBs, RCBOs, RCCBs, and SPDs in one factory export shipment.
| Specification Element | VAF1-40 (Standard) | VAF3-40M (Magnetic) | Procurement Impact |
|---|---|---|---|
| Example Order Code | VAF1-40 C16 A30 | VAF3-40M B16 A30 | Eliminates rating/curve ambiguity on POs |
| Rated Current Mix (In) | 6, 10, 13, 16, 20, 25, 32, 40 A | 6, 10, 13, 16, 20, 25, 32, 40 A | Mixed-amperage master cartons supported |
| Curve & Residual Rating | B or C · Type A 10 / 30 mA | B or C · Type A 10 / 30 mA | Match national residential/commercial code |
| Compliance & Branding | IEC/EN 62606 · 61009-1 | IEC/EN 62606 · 61009-1 | VIOX stock or laser-marked private label |
Sourcing Private-Label or Container-Volume AFDDs?
Review VIOX factory tooling, IEC/EN 62606 test capabilities, laser marking, and distributor OEM programs on our dedicated manufacturer hub.
AFDD technical resources.
Use each guide for a distinct decision: device function, standard scope, comparison and testing.
AFDD Engineering & Sourcing FAQ
Direct answers on IEC/EN 62606 arc detection, VAF1-40 vs VAF3-40M magnetic selection, 70 m cable limits, and OEM supply.
Model Selection What is the practical difference between VIOX VAF1-40 and VAF3-40M?
Both VAF1-40 and VAF3-40M are 1-module 1P+N 4-in-1 devices combining IEC/EN 62606 arc-fault detection with IEC/EN 61009-1 Type A residual-current (10 mA or 30 mA), overload, and 6 kA short-circuit protection from 6 A to 40 A (B or C curve).
VAF3-40M is the magnetic version designed for specifications and national wiring rules that require a magnetic residual-current tripping mechanism alongside integrated arc-fault detection.
Standards Why do IEC 60364-4-42, BS 7671, and DIN VDE 0100-420 require AFDDs in addition to MCBs and RCBOs?
Conventional MCBs and RCBOs protect against overloads, short circuits, and earth leakage, but a high-impedance series arc at a loose socket terminal or damaged cord often stays below rated current (In) and produces zero earth-leakage current.
IEC/EN 62606 AFDDs analyze high-frequency current noise and arc-shoulder waveform signatures to disconnect hazardous series and parallel arcs before localized heating ignites surrounding building materials.
Protection Scope Does a VIOX VAF1-40 or VAF3-40M replace a separate RCBO on 240 V AC final circuits?
Yes, on single-phase 240 V AC 50 Hz final circuits up to 40 A and 6 kA prospective fault current where Type A 10 mA or 30 mA residual-current protection is specified. Both VAF1-40 and VAF3-40M integrate AFDD, Type A RCD, overload, and short-circuit protection in one 1P+N 1-module footprint.
For circuits requiring Type B (smooth DC > 6 mA) leakage protection—such as EV chargers or transformerless inverters—specify a dedicated Type B RCBO according to the installation code.
Installation What are the maximum cable length, terminal torque, and backup fuse limits for VIOX AFDDs?
Per the VIOX VAF1-40 and VAF3-40M catalog specifications, maximum connected cable length between the distribution board and the furthest socket outlet is 70 m to preserve high-frequency arc-signal detection integrity.
Screw terminals accept 1–25 mm² conductors tightened to 2–2.4 N·m (top or bottom load connection, left or right neutral position), with a maximum upstream short-circuit backup fuse (SCPD) of 100 A gG.
Reliability How do IEC 62606 AFDDs avoid nuisance tripping from power tools, vacuum cleaners, and LED drivers?
IEC/EN 62606 mandates strict unwanted-tripping immunity tests against brushed motors, vacuum cleaners, phase-angle dimmers, halogen lamps, and switch-mode power supplies.
VIOX AFDD electronics evaluate multi-criteria high-frequency spectrum patterns, current-zero shoulder duration, and persistence thresholds to reject benign switching transients while tripping reliably on sustained dangerous arcs.
OEM / B2B Supply Can VIOX supply OEM or private-label AFDDs with IEC/EN 62606 and 61009-1 compliance packs?
Yes. VIOX supports panel builders, electrical wholesalers, and regional switchgear brands with factory-direct VAF1-40 and VAF3-40M supply, laser-marked private labeling, custom packaging, and model-matched IEC/EN 62606 and IEC/EN 61009-1 test documentation.
Send your target current mix (6–40 A, B/C curve, 10/30 mA) and destination market requirements, or visit our dedicated AFDD Manufacturer page for OEM program details.
Send one complete AFDD requirement.
Include model, current, B/C characteristic, residual-current sensitivity, quantity, destination market, documents and OEM requirements.