The VIOX VRL7E is an electronic Type AC RCBO for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N design combines residual-current, overload and short-circuit protection with 2-40 A ratings, B or C tripping characteristics and 10, 30 or 100 mA sensitivities. It provides a 4.5 kA short-circuit capacity and mounts on a standard 35 mm DIN rail.

Corrente nominale
2-40 A
Corrente Differenziale
10, 30, 100 mA
Configurazione del palo
1P+N
Capacità di rottura
4,5 kA

Panoramica

The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.

Caratteristiche

  • Electronic Type AC residual-current detection.
  • Residual-current, overload and short-circuit protection.
  • 1P+N configuration for AC 230 V circuits.
  • B and C thermomagnetic release characteristics.
  • 4.5 kA rated short-circuit capacity.
  • Indicatore di corrente di guasto integrato.
  • 35 mm DIN-rail mounting with a fast-clip device.

Specifiche tecniche

Dati elettrici

ParametroSpecifica
Operating ModeElectronic type
Corrente nominale2, 4, 6, 10, 16, 20, 25, 32, 40 A
Configurazione del palo1P+N
Tensione operativa nominale230 V AC
Frequenza nominale50/60 Hz
Tensione nominale di isolamento250 V
Tensione nominale di tenuta all'impulso4 kV, 1.2/50 μs
Tensione di prova dielettrica2 kV per 1 minuto

Dati di protezione

ParametroSpecifica
Residual-Current TypeTipo AC
Thermomagnetic Release CharacteristicB, C
Corrente residua nominale di funzionamento10, 30, 100 mA
Potere nominale di chiusura e di apertura residuo500 A
Rated Short-Circuit Capacity4,5 kA
Break Time at IΔn≤ 0.1 s
Grado di inquinamento2

Dati meccanici e di installazione

ParametroSpecifica
Vita elettrica4.000 operazioni
Vita meccanica10.000 operazioni
Fault-Current Indicator
Grado di protezioneIP20
Terminal ConnectionCable / pin-type busbar / U-type busbar
Cable Terminal Capacity25 mm², AWG 18-5, top/bottom
Busbar Terminal Capacity25 mm², AWG 18-3, top/bottom
Montaggio35 mm DIN rail to EN 60715; fast-clip device
Supply ConnectionFrom top

Environmental Data

ParametroSpecifica
Temperatura ambiente-5 °C to +40 °C; daily average ≤ 35 °C
Temperatura di stoccaggio-25 °C to +70 °C

Standard

ParametroSpecifica
StandardIEC/EN 61009-1

Guida alla selezione

Elemento del codiceSignificatoValori disponibili
VIdentificazione azienda VIOXV
RLFamiglia di prodotti RCBORL
7ESerie di progettazione7E
CurvaCurva di intervento per sovracorrenteB o C
AttualeCorrente nominale2-40 A
SensibilitàCorrente differenziale nominale di intervento10, 30 or 100 mA
PoliOrdering designation2P in the catalog example
Example ModelConfigurazione
VRL7E-B16-10B curve, 16 A, 10 mA
VRL7E-C20-30C curve, 20 A, 30 mA
VRL7E-C40-100C curve, 40 A, 100 mA

Curva di intervento

Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.

Corrente nominale

Select one of the listed ratings from 2 A to 40 A.

Sensibilità residua

Select a rated residual operating current of 10, 30 or 100 mA.

Configurazione del circuito

The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.

Curve di viaggio

The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.

Protection CharacteristicAvailable Option
Thermomagnetic ReleaseB or C curve
Residual-Current Break Time≤ 0.1 s at IΔn

Dimensioni

VRL7E Type AC RCBO dimensional drawing
VRL7E Type AC RCBO dimensional drawing.

Applicazioni

  • Residential final distribution boards.
  • Commercial final distribution circuits.
  • Light industrial distribution boards.
  • AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.

Installazione

  • Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
  • Connect the supply from the top.
  • Use cable, pin-type busbar or U-type busbar connections as specified.
  • Observe the stated 25 mm² terminal capacity for cable and busbar connections.
  • Install within the specified ambient temperature range of -5 °C to +40 °C.

FAQ

What residual-current type does the VRL7E use?

It uses electronic Type AC detection for sinusoidal alternating residual currents.

Quali correnti nominali In sono disponibili?

The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.

Which residual-current sensitivities are available?

The available rated residual operating currents are 10, 30 and 100 mA.

What is the VRL7E short-circuit capacity?

The rated short-circuit capacity is 4.5 kA.

How is the VRL7E installed?

It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.