VIOX Electric
Language

RCCB Manufacturer for OEM & Wholesale Supply

Source residual current circuit breakers from VIOX for distribution, private-label ranges and panel-building projects. Align the selected RCCB type with model documents, sample requirements, marking and packaging before confirming your order.

VIOX electrical testing equipment
VIOX electrical testing equipment

Build an RCCB supply program around your market.

Electrical distributors

Define your range, model documents, packaging and replenishment references.

Private-label brands

Review the product identity, marking and sample approval requirements for your brand.

Panel builders & project buyers

Specify the residual-current response and coordinate the RCCB with the circuit’s overcurrent protection.

RCCB manufacturing at a glance

Company & locationVIOX Electric · Yueqing, Zhejiang, China
Product scopeRCCB (residual-current protection without integral overcurrent protection) for final distribution
Published seriesVKL11 / VKL11F / VKL11B / VKL11-EV
Poles & rated current2P / 4P, 16–100A
Residual-current typesAC, A, ASi, F, B, B+ and EV (A-EV / F-EV)
StandardsIEC/EN 61008-1; Type F and Type B additionally IEC/EN 62423; VKL11-EV per variant (see Type B & EV section)
DocumentsSeries documents · Certificates & reports
OEM / private labelmarking, labels and packaging per approved artwork
MOQ, samples & lead timeconfirmed by series in the quotation

Available combinations depend on the series and exact model; refer to the corresponding Product Catalog.

Four RCCB families. One clear order specification.

Choose a candidate family here. Use the RCCB selection page for the detailed ratings comparison and selector.

VIOX VKL11 RCCB

VKL11

Type AC / A / ASi

Distribution ranges using Type AC, A or ASi configurations.

VIOX VKL11F RCCB

VKL11F

Type F

Type F supply for equipment with mixed-frequency residual currents.

VIOX VKL11B RCCB

VKL11B

Type B / B+

Type B or B+ supply where the specified residual-current response requires it.

VIOX VKL11-EV RCCB

VKL11-EV

Type A EV / F EV

Mode 3 EV charging configurations, with variant-specific DC detection and document requirements.

Compare types, poles, current and sensitivity before choosing a model.

Compare all four RCCB families

Make RCCB quality checks model-specific.

Ask for the inspection and test evidence relevant to your selected configuration. The checks below define the review scope; they are not a claim that every test is performed on every unit.

VIOX electrical product assembly line
VIOX assembly facilities. Confirm the process and inspection plan for your RCCB order.

Residual operating current

Requested IΔn, waveform and exact RCCB type.

Evidence to request: Model-specific operating-current test conditions and results.

Operating time

Instantaneous, short-delay or selective version, where offered.

Evidence to request: Time limits and measured results identified by variant and test condition.

Test-button function

Supply voltage, connection and test-button operation.

Evidence to request: Applicable functional inspection method; not a substitute for calibrated trip testing.

Insulation & mechanical checks

Insulation verification, terminal condition and operating mechanism.

Evidence to request: Agreed inspection scope, acceptance criteria and order identification.

Short-circuit coordination

RCCB conditional rating and upstream MCB or fuse.

Evidence to request: Rating definition, voltage and required backup protection or coordination reference.

Production inspection

Checks recorded under the agreed production and order inspection plan.

Type testing

Design or variant testing under stated standards and test conditions.

External certification

Third-party documentation covering the specific models and ratings listed in its scope.

Match the documents to the model and market.

A standard named in a catalog does not by itself confirm a certificate. Request the document set for the exact variant before purchase approval.

Series & typePublished ratingsDocuments
VKL11 — Type AC/A/ASi16–100A, IΔn 10mA (16–40A only) / 30 / 100 / 300mAProduct Catalog
VKL11F — Type F16–100A, 30/100/300mAProduct Catalog
VKL11B — Type B/B+16–100A, B: 30–500mA, B+: 30–300mAProduct Catalog
VKL11-EV — Type A EV / F EV16–100A, A-EV: 10–300mA, F-EV: 30mAProduct Catalog

VKL11

Identify AC, A or ASi, the rated values and pole arrangement. Review the applicable IEC/EN 61008-1 documentation and any destination-specific requirements.

VKL11F

Confirm the Type F response, operating conditions and exact configuration against the applicable IEC/EN 62423 and IEC/EN 61008-1 documents.

VKL11B

Identify Type B or B+ explicitly. Check the Type B document scope separately from any DIN VDE 0664-400 evidence required for a B+ variant.

VKL11-EV

Identify A-EV or F-EV and the integrated DC detection function. Request evidence for the declared 6mA maximum switch-off threshold and the standards applicable to that exact variant. Do not treat EV variants as interchangeable with Type B.

Type B and EV RCCB supply: VKL11B and VKL11-EV

VKL11B Type B detects AC, pulsating DC and smooth DC residual currents at frequencies up to 1 kHz. Type B+ extends detection up to 20 kHz. DIN VDE 0664-400 evidence must be checked for the exact B+ variant; it must not be applied to Type B or other series as a blanket certification claim.

VKL11-EV is intended for Mode 3 charging. A-EV references IEC/EN 61008-1 and IEC 62955, with a maximum 6mA smooth DC switch-off threshold. F-EV references IEC/EN 61008-1, EN 62423 and OVE E8601. EV variants and Type B RCCBs are not interchangeable; select the variant against the charging system requirements and its supporting documents.

VKL11B product details · VKL11-EV product details · Verify model-specific certificates

From RCCB specification to repeat supply.

Use the same model and revision references across the sample, artwork, documentation and purchase order.

  1. 1

    Confirm the series and market

    Define RCCB type, voltage, In, IΔn, poles, quantity and destination.

    Approval reference
    Order specification brief
  2. 2

    Review marking and packaging

    Agree the model designation, rating labels, brand artwork and packaging requirements.

    Approval reference
    Artwork and packaging references
  3. 3

    Approve the sample scope

    Specify the sample configuration and the checks required before bulk-order approval.

    Approval reference
    Sample identification and review criteria
  4. 4

    Match the document set

    Check the model, rating, variant and destination against each requested certificate or report.

    Approval reference
    Model-to-document checklist
  5. 5

    Confirm the bulk order

    Agree the technical configuration, quantity, packing and commercial terms in writing.

    Approval reference
    Approved purchase-order specification
  6. 6

    Identify repeat-order versions

    Reference the approved model, sample and artwork when ordering replenishment.

    Approval reference
    Revision-controlled reorder reference

OEM approval and certification scope

Logo and marking, rating labels, packaging and instruction-language requirements are reviewed against approved artwork and the certification scope of the exact model. Private labeling does not automatically transfer certification.

Changes to housing materials, critical internal components or rated markings require reassessment before order approval.

Wholesale order workflow

Confirm the sample configuration and approval references before the bulk order. For repeat supply, reference the approved model, sample, artwork and document revision so the replenishment order can be checked against the agreed version.

Prepare your RCCB sample or bulk-order request.

Send the details you have. Identify anything still to be confirmed instead of substituting assumed ratings or certificates.

Product configuration

Series · RCCB type · voltage · In · IΔn · poles · timing variant · upstream protection

Market & branding

Destination · required documents · VIOX or private label · marking · packaging

Order requirements

Sample quantity · bulk quantity · expected repeat demand · requested delivery · requirement file

RCCB manufacturing FAQ

Is VIOX an RCCB manufacturer in China?

VIOX Electric is based in Yueqing, Zhejiang, China and supplies RCCBs for final distribution, including OEM and wholesale orders. RCCBs provide residual-current protection without integral overcurrent protection.

Which RCCB series does VIOX manufacture?

The published series are VKL11, VKL11F, VKL11B and VKL11-EV. Available combinations depend on the series and exact model; refer to the corresponding Product Catalog.

Does VIOX supply Type B and EV RCCBs?

Yes. VKL11B covers Type B and B+ variants, while VKL11-EV covers A-EV and F-EV configurations for Mode 3 charging. EV variants and Type B are not interchangeable. Verify the standards and evidence for the exact variant.

What documents are available for each RCCB model?

The series document table links the Product Catalog for each of the four published series. Request and verify any certificate or test report against the exact model, rating and variant; a catalog standard reference is not a certificate.

Can VIOX do OEM / private label RCCB?

Marking, labels and packaging are reviewed against approved artwork and the model certification scope. Private labeling does not automatically transfer certification. Changes to housing materials, critical internal components or rated markings require reassessment.

What is the MOQ and lead time?

MOQ, samples and lead time are confirmed by series in the quotation.

How can I verify a certificate?

Match the document scope to the exact model, ratings and variant. Use the Certificates & Reports page at https://viox.com/certifications/ to begin the document review. Certificates & Reports

Confirm the model. Align the evidence. Approve the order.

Start with your RCCB requirements and destination market.

Talk to VIOX about RCCB supply