VIOX Electric
Language

Cable Lug Manufacturer

Compare VIOX cable lug series for dependable conductor termination across panel building, power distribution and industrial equipment.

Conductor matchingMaterial and cross-section

Stud and palmHole size and geometry

Finish and environmentBare or plated series

Installation toolingDie and crimp process

VIOX Cable Lug SERIESPublished product range

What is a cable lug?

A cable lug terminates a conductor so it can be bolted or otherwise connected to a busbar, terminal, switchgear component or equipment connection point.

Selection requires conductor material, construction and cross-section, lug barrel, palm and stud dimensions, finish, installation tooling, crimp process, environment and the applicable connection standard.

Match conductor and lugConfirm conductor material, cross-section and barrel dimensions.
Prepare and crimpUse the specified strip length, die, tool and crimp sequence.
Connect and inspectClean the interface, use approved hardware and verify the completed joint.

How to choose a cable lug

Match the conductor first, then verify stud geometry, material, finish and crimping method.

Conductor material and size

Use a lug intended for the actual copper or aluminum conductor and cross-section.

Stud hole and palm geometry

Confirm bolt size, palm width, orientation and available connection space.

Material and plating

Match corrosion, interface-metal and environmental requirements.

Tool and die

Use the approved crimping system, die reference, strip length and inspection process.

Treat the crimp as a complete connection system

Conductor, lug, die, tool, crimp sequence and bolted interface all affect connection quality.

CConductor material and cross-section
LLug barrel, palm and stud hole
TTool, die and inspection method
Read the Cable Lug selection guide

Compare published Cable Lug series

Published series ranges are a screening aid, not an ordering matrix. A hole-diameter range does not mean every conductor size is available with every hole. Open the linked model table and confirm the exact conductor, barrel, palm and hole combination. — means not explicitly verified; model numbers and barrel diameters are not converted into conductor cross-sections.

SeriesConductor sizeStud holeMaterialFinish
AU—8.4–17 mmAluminumTin-plated
C45—Not applicable — pin terminalT2 copperElectro-tin plated
DL10–800 mm²8.5–21 mm; DL-630/800: square palm, hole not specifiedAluminum—
DT10–630 mm²—T2 copperTin plating available; confirm order
DT(G)10–630 mm²6.5–22.5 mmT2 copperTin plating available; confirm order
DTL10–800 mm² (product-page model legend)8.5–21 mm; DTL-630/800: square palm, hole not specifiedCopper / aluminum—
DTL-110–630 mm²10.5–17 mmCopper / aluminum—
DTL-210–630 mm²13–17 mmCopper / aluminum—
DTL-2S10–300 mm²8.5–13 mmCopper / aluminum—
DTL-3—10.5–17 mmCopper / aluminum—
DTL-5—10.5–17 mmCopper / aluminum—
DTL-8——Copper / aluminum—
DTS35–400 mm²10.5–17 mm; two-hole palmT2 copperTin plating available; confirm order
JG(DTGY)— (published range and model table need reconciliation)6.5–21 mm in published model tableT2 copperTin-plated
OT— (A-coded models are not mm²)5.2–18.5 mmCopperTin plating available; confirm order

Cable Lug Selection Questions

Quick answers for preliminary product-family comparison before detailed circuit verification.

How is cable lug size selected?

Match conductor material, construction and cross-section to the published lug barrel and application data.

Can a copper lug be used on aluminum cable?

Only use a lug and preparation method explicitly approved for the conductor and interface metals.

How is the stud hole selected?

Match the equipment bolt while checking palm width, edge distance, orientation and connection space.

Why does the crimping die matter?

The die and tool create the specified compression geometry; an incorrect system can produce an unreliable connection.

What should be inspected after crimping?

Follow the approved process for crimp position, number, visual condition, conductor insertion and any required pull or electrical testing.

Need the Right Cable Lug?
Let’s Match the Conductor and Stud.

Send the conductor material and size, stud diameter, palm orientation, environment, quantity and target market.

Request Cable Lug Support