VIOX Điện
Language

RCBO loại AC VRL7E

The VIOX VRL7E is an electronic Type AC RCBO for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N design combines residual-current, overload and short-circuit protection with 2-40 A ratings, B or C tripping characteristics and 10, 30 or 100 mA sensitivities. It provides a 4.5 kA short-circuit capacity and mounts on a standard 35 mm DIN rail.

Bình Hiện Tại
2-40 A
Dòng rò (Residual Current)
10, 30, 100 mA
Cấu hình cực
1P+N
Khả Năng Phá Vỡ
4.5 kA

Tổng quan

The VIOX VRL7E is an electronic Type AC residual current circuit breaker with overcurrent protection for AC 230 V, 50/60 Hz final distribution circuits. Its 1P+N configuration combines residual-current, overload and short-circuit protection in one compact device. The Type AC detection system responds to sinusoidal alternating residual currents, while B and C thermomagnetic tripping characteristics support different circuit and load requirements. The RCBO is intended for residential, commercial and light industrial distribution boards and installs on a standard 35 mm DIN rail.

Đặc trưng

  • Electronic Type AC residual-current detection.
  • Residual-current, overload and short-circuit protection.
  • 1P+N configuration for AC 230 V circuits.
  • B and C thermomagnetic release characteristics.
  • 4.5 kA rated short-circuit capacity.
  • Integrated fault-current indicator.
  • 35 mm DIN-rail mounting with a fast-clip device.

Thông số kỹ thuật

Electrical Data

Tham sốĐặc điểm kỹ thuật
Operating ModeElectronic type
Bình Hiện Tại2, 4, 6, 10, 16, 20, 25, 32, 40 A
Cấu hình cực1P+N
Điện áp hoạt động định mức230 V AC
Tần số định mức50/60 Hz
Điện áp cách điện định mức250 V
Điện áp chịu xung định mức4 kV, 1.2/50 μs
Điện áp thử nghiệm điện môi2 kV for 1 minute

Protection Data

Tham sốĐặc điểm kỹ thuật
Residual-Current TypeLoại AC
Thermomagnetic Release CharacteristicB, C
Rated Residual Operating Current10, 30, 100 mA
Rated Residual Making and Breaking Capacity500 A
Rated Short-Circuit Capacity4.5 kA
Break Time at IΔn≤ 0.1 s
Mức độ ô nhiễm2

Mechanical and Installation Data

Tham sốĐặc điểm kỹ thuật
Cuộc sống điện4,000 operations
Cuộc sống cơ học10.000 lần hoạt động
Fault-Current IndicatorYes
Mức độ bảo vệIP20
Terminal ConnectionCable / pin-type busbar / U-type busbar
Cable Terminal Capacity25 mm², AWG 18-5, top/bottom
Busbar Terminal Capacity25 mm², AWG 18-3, top/bottom
Lắp ráp35 mm DIN rail to EN 60715; fast-clip device
Supply ConnectionFrom top

Environmental Data

Tham sốĐặc điểm kỹ thuật
Nhiệt độ môi trường-5 °C to +40 °C; daily average ≤ 35 °C
Nhiệt độ lưu trữ-25 °C to +70 °C

Chuẩn

Tham sốĐặc điểm kỹ thuật
ChuẩnIEC/EN 61009-1

Hướng dẫn lựa chọn

Code ElementÝ nghĩaAvailable Values
VVIOX enterprise identificationV
RLRCBO product familyRL
7EDesign series7E
Đường cong đặc tínhĐường cong tác động quá dòngB hoặc C
Hiện hànhDòng điện định mức2-40 A
Nhạy cảmDòng điện dư định mức khi vận hành10, 30 or 100 mA
CựcOrdering designation2P in the catalog example
Example ModelCấu hình
VRL7E-B16-10B curve, 16 A, 10 mA
VRL7E-C20-30C curve, 20 A, 30 mA
VRL7E-C40-100C curve, 40 A, 100 mA

Đường cong vấp ngã

Select a B or C thermomagnetic release characteristic according to the circuit and load requirements.

Bình Hiện Tại

Select one of the listed ratings from 2 A to 40 A.

Residual Sensitivity

Select a rated residual operating current of 10, 30 or 100 mA.

Cấu hình mạch

The technical specification identifies a 1P+N configuration for AC 230 V final distribution circuits.

Đường cong chuyến đi

The VRL7E is available with B and C time-current tripping characteristics. The catalog provides time-current graphs for both curves and specifies a residual-current break time of no more than 0.1 seconds at IΔn.

Protection CharacteristicAvailable Option
Thermomagnetic ReleaseB or C curve
Residual-Current Break Time≤ 0.1 s at IΔn

Kích thước

VRL7E Type AC RCBO dimensional drawing
VRL7E Type AC RCBO dimensional drawing.

Ứng dụng

  • Residential final distribution boards.
  • Commercial final distribution circuits.
  • Light industrial distribution boards.
  • AC 230 V circuits requiring combined Type AC residual-current and overcurrent protection.

Cài đặt

  • Install on a 35 mm DIN rail conforming to EN 60715 using the fast-clip device.
  • Connect the supply from the top.
  • Use cable, pin-type busbar or U-type busbar connections as specified.
  • Observe the stated 25 mm² terminal capacity for cable and busbar connections.
  • Install within the specified ambient temperature range of -5 °C to +40 °C.

Câu hỏi thường gặp

What residual-current type does the VRL7E use?

It uses electronic Type AC detection for sinusoidal alternating residual currents.

What rated currents are available?

The available ratings are 2, 4, 6, 10, 16, 20, 25, 32 and 40 A.

Which residual-current sensitivities are available?

The available rated residual operating currents are 10, 30 and 100 mA.

What is the VRL7E short-circuit capacity?

The rated short-circuit capacity is 4.5 kA.

How is the VRL7E installed?

It mounts on a 35 mm DIN rail conforming to EN 60715 and uses a fast-clip device. The supply connection is from the top.

Need a Product Quote?
Hãy cùng chúng tôi thực hiện dự án này.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Yêu cầu báo giá