Residual Current Circuit Breakers (RCCB)

Compare VIOX RCCB series by rated current, pole configuration, rated residual operating current and waveform type for low-voltage earth-leakage protection.

حفاظتی فنکشنResidual-current detection

پول کے اختیارات2P and 4P by series

حساسیتConfirm IΔn by model

عام RCCB ویوفارم اقسامMatch load waveforms

VIOX RCCB SERIESشائع شدہ پروڈکٹ رینج

What is a residual current circuit breaker?

An RCCB monitors the balance between current flowing through the outgoing and returning conductors. When the residual current exceeds the device operating characteristics, it disconnects the circuit to support earth-leakage protection.

An RCCB is not selected by rated current alone. Pole configuration, rated residual operating current, RCCB type, circuit voltage and coordination with overload and short-circuit protection must also match the installation.

How to choose an RCCB

Use these checkpoints for preliminary comparison, then verify the exact model documentation and installation requirements.

Rated residual current

Match IΔn to the protection objective and applicable installation requirements.

RCCB waveform type

Choose Type AC, A, F, B or another available type according to the connected loads and standards.

پول کنفیگریشن

Confirm the required 2P or 4P arrangement, circuit voltage and neutral configuration.

Overcurrent coordination

Coordinate the RCCB with the required MCB, fuse or other overcurrent protective device.

RCCB waveform types

Type availability varies by VIOX series. Confirm the product datasheet and applicable installation standard before selection.

اے سیسائنوسائیڈل اے سی (AC) ریزیڈول کرنٹ
اےAC اور پلسٹنگ DC بقایا کرنٹ۔
F/BApplications with more complex frequency or DC components
Read the RCCB selection guide

Compare published RCCB series

خالی خانے کا مطلب ہے کہ موجودہ پروڈکٹ سمری میں یہ ویلیو دستیاب نہیں ہے۔ تفصیلات (specification) سے پہلے ماڈل کا صفحہ کھولیں یا اس کا ڈیٹا شیٹ طلب کریں۔.

سیریزکھمبےشرح شدہ کرنٹعام RCCB ویوفارم اقسامحساسیت
VIOX VKL11F2P
VIOX VKL11F4P
VIOX VRC1-125-B2P100A
VIOX VRC3-632P25A
VIOX VKL112P
VIOX VKL114P
VIOX VKL112PA ٹائپ کریں۔
VIOX VKL114PA ٹائپ کریں۔

RCCB selection questions

Quick answers for comparing a residual-current protection family before detailed circuit verification.

آر سی سی بی کس چیز سے بچاتا ہے؟

An RCCB detects an imbalance between outgoing and returning current and disconnects the circuit when the residual current exceeds its operating characteristics. It is used for earth-leakage protection in an appropriately designed installation.

Does an RCCB provide overload and short-circuit protection?

An RCCB is selected for residual-current protection and does not normally replace overcurrent protection. The circuit may also require an MCB, fuse or a combined RCBO according to the installation design.

What is the difference between Type AC, A, F and B RCCBs?

The type identifies the residual-current waveforms the device is designed to detect. The correct type depends on the connected equipment, applicable standards and manufacturer documentation; availability varies by VIOX series.

How should RCCB sensitivity be selected?

The rated residual operating current must match the protection objective and the applicable installation rules. Confirm the required sensitivity on the individual model page or datasheet before specification.

Can an RCCB be selected by rated current alone?

No. Rated current, pole configuration, rated residual operating current, RCCB type, circuit voltage and coordination with overcurrent protection must all be checked.

Need the Right RCCB?
آئیے مل کر اس کی تصدیق کرتے ہیں۔.

Send the circuit voltage, rated current, pole configuration, required sensitivity, connected loads, quantity and target market. VIOX will help identify the most relevant published series.

Request RCCB Support