RCCB Manufacturer & OEM Supplier

Residual Current Circuit Breakers (RCCB)

Compare VIOX RCCB series for conventional AC, pulsating DC, mixed-frequency, smooth-DC and EV charging applications. Published models cover 16–100A ratings in 2P and 4P configurations.

  • Type AC, A, ASi, F, B, B+ and EV variants
  • Model-specific datasheets and documentation review
  • OEM marking, packaging and wholesale supply
VKL11 بقایا کرنٹ سرکٹ بریکر
4Published series
16–100ARated-current range
2P / 4Pپول کنفیگریشنز
AC → EVApplication-specific coverage

Choose by residual-current type

Which RCCB series should you start with?

Begin with the residual-current waveform and application, then confirm rated current, IΔn, poles, voltage and upstream overcurrent protection.

01عام مقصد کے لیے تحفظ
VKL11 بقایا کرنٹ سرکٹ بریکر

VKL11

Start here for conventional AC or pulsating-DC residual-current protection in residential, commercial and distribution applications.

قسم
Type AC / A / ASi
شرح شدہ کرنٹ
16–100A
کھمبے
2P / 4P
02Mixed-frequency loads
VKL11F ٹائپ F ریزیڈول کرنٹ سرکٹ بریکر

VKL11F

For circuits with single-phase electronic equipment and mixed-frequency residual currents up to the model’s declared operating range.

قسم
ایف ٹائپ کریں۔
شرح شدہ کرنٹ
16–100A
کھمبے
2P / 4P
03Smooth DC & high frequency
VKL11B ٹائپ B/B+ ریزیڈول کرنٹ سرکٹ بریکر

VKL11B

For installations where smooth DC and higher-frequency residual currents must be detected, subject to the exact system and model requirements.

قسم
ٹائپ بی / بی+
شرح شدہ کرنٹ
16–100A
کھمبے
2P / 4P
04Mode 3 EV charging
VKL11-EV الیکٹرک وہیکل ریزیڈول کرنٹ سرکٹ بریکر

VKL11-EV

For Mode 3 EV charging, with Type A or Type F residual-current protection and integrated smooth-DC detection that switches off at a maximum 6mA threshold for the declared variants.

قسم
Type A EV / F EV
شرح شدہ کرنٹ
16–100A
کھمبے
2P / 4P

Interactive specification builder

VIOX RCCB Selector

Describe the supply system, connected load and protection objective. The selector builds a preliminary RCCB specification, identifies a candidate VIOX series and lists every item that still needs verification.

Question 1 of 10
Which market or standard applies?

Use the project requirement when it is already known.

Is the circuit single-phase or three-phase?

This provides a preliminary 2P or 4P direction.

What is the working voltage?

Choose the declared circuit voltage, not an assumed regional value.

What is the main application?

The connected equipment determines the residual-current waveform that must be detected.

Does the load use an inverter, rectifier or electronic speed control?

Examples include VFDs, inverter-driven compressors and power-electronic equipment.

Can the equipment produce smooth DC residual current?

Check the equipment manufacturer’s protective-device requirements before answering.

For EV charging, is 6mA DC detection already provided?

Select “Not applicable” when this is not an EV charging circuit.

What current ratings are being considered?

RCCB rated current and upstream overcurrent protection must be coordinated separately.

What is the main protection objective?

This guides the IΔn discussion; local rules and the project design remain controlling.

Is there another RCD upstream?

An upstream RCD can create time-delay and selectivity requirements.

Model-level comparison

Compare VKL11, VKL11F, VKL11B and VKL11-EV

Use the table to shortlist a series. Verify the exact rating combination and destination-market documents before ordering.

سیریزعام RCCB ویوفارم اقسامشرح شدہ کرنٹRated residual currentکھمبےRated voltagePublished standards
VKL11عام مقصد کے لیے تحفظType AC / A / ASi16–100A10mA* / 30mA / 100mA / 300mA2P / 4P240V / 415V ACIEC/EN 61008-1
VKL11FMixed-frequency loadsایف ٹائپ کریں۔16–100A30mA / 100mA / 300mA2P / 4P230/240V / 400/415V ACIEC/EN 62423 · IEC/EN 61008-1
VKL11BSmooth DC & high frequencyٹائپ بی / بی+16–100AB: 30–500mA · B+: 30–300mA2P / 4P230/240V / 400/415V ACType B: IEC/EN 62423 + IEC/EN 61008-1 · Type B+: confirm DIN VDE 0664-400 for the exact variant
VKL11-EVMode 3 EV chargingType A EV / F EV16–100AA-EV: 10–300mA · F-EV: 30mA2P / 4P240V / 415V ACA-EV: IEC/EN 61008-1 + IEC 62955 · F-EV: IEC/EN 61008-1 + EN 62423 + OVE E 8601

* The 10mA VKL11 option applies to published 16–40A configurations. IEC 62423 covers Type F and Type B; a Type B+ claim must be confirmed against the exact variant and applicable DIN VDE 0664-400 evidence. The VKL11-EV catalog lists IEC 62955 for VKL11A-EV, while VKL11F-EV is listed with EN 62423 and OVE E 8601. Confirm the ordered variant and supporting documents.

ایپلیکیشن گائیڈ

Match the RCCB series to the load profile.

Start with the connected equipment and expected residual-current waveform. Then verify the required type, sensitivity, poles, voltage and overcurrent coordination.

Electrical distribution panels for general RCCB applications
VKL11

جنرل ڈسٹری بیوشن

Residential, commercial and panel-distribution circuits requiring the appropriate Type AC, A or ASi variant.

View VKL11
Engineer inspecting a variable-frequency-drive control cabinet for an industrial pump system
VKL11F

Electronic & Variable-Frequency Loads

Single-phase drives, heat pumps, HVAC and electronic equipment that may produce mixed-frequency residual currents.

View VKL11F
Solar photovoltaic and battery energy storage installation
VKL11B

Power Conversion Systems

PV, battery storage, UPS and drive applications where the system requires smooth-DC residual-current detection.

View VKL11B
Electric vehicle connected to a charging point
VKL11-EV

Mode 3 EV Charging

Residential and commercial Mode 3 charging points requiring a declared A-EV or F-EV configuration.

View VKL11-EV

Before placing an order

Turn the circuit requirement into a checkable RCCB specification.

An RCCB should not be chosen from one headline rating. Record the complete electrical requirement and match it to the exact published model.

Open the complete RCCB selection guide
  1. 01

    Confirm system voltage and conductors

    Define the single-phase or three-phase circuit, neutral arrangement and required 2P or 4P switching.

  2. 02

    Set rated current and IΔn

    State both the continuous-current rating and the required residual operating current.

  3. 03

    Match the residual-current waveform

    Use the connected equipment manufacturer’s requirements to select Type AC, A, F, B, B+ or an EV variant.

  4. 04

    Coordinate overcurrent protection

    Confirm the MCB, fuse or other overcurrent device because an RCCB does not provide overload or short-circuit protection.

  5. 05

    Verify the exact document set

    Match the model, rating, standard, destination market, certificate request and OEM artwork before production.

Manufacturer & OEM support

Qualify the product and the supply process.

VIOX supports distributors, panel builders and private-label electrical brands with published model data, sample approval and order-specific documentation review.

Purchase questions

RCCB sourcing FAQ

Short answers for model selection and document review.

Which VIOX RCCB series should I start with?

Start with VKL11 for Type AC, A or ASi requirements, VKL11F for Type F mixed-frequency loads, VKL11B for Type B or B+ smooth-DC detection, and VKL11-EV for the declared Mode 3 EV charging configurations. Final selection must follow the connected equipment, system design and applicable rules.

Does an RCCB provide overload and short-circuit protection?

No. An RCCB provides residual-current protection and must be coordinated with the required MCB, fuse or other overcurrent protective device. Use an RCBO where combined residual-current and overcurrent protection is required in one device.

What information is needed for an RCCB quotation?

Provide the circuit voltage, rated current, pole configuration, RCCB type, rated residual operating current, quantity, destination market, required documents and any OEM marking or packaging requirements.

Are the same certificates and reports available for every RCCB series?

Documentation must be confirmed for the exact model, rating and destination market. Request the applicable datasheet, declaration, certificate or test document before approving a product for a project or private-label program.

Does VKL11-EV include 6mA smooth-DC detection?

The published VKL11-EV catalog states that the A-EV and F-EV variants incorporate smooth-DC residual-current detection and switch off at a maximum 6mA threshold. IEC 62955 is listed for VKL11A-EV, while VKL11F-EV is listed with EN 62423 and OVE E 8601. Confirm the exact variant and supporting documents before specification.

Ready for model review?

Send one complete RCCB requirement.

Include voltage, current, poles, RCCB type, IΔn, quantity, destination market, required documents and OEM details. VIOX will review the closest published series.

Request RCCB datasheets & quote