VKL11 Residual Current Circuit Breaker

The VIOX VKL11 residual current circuit breaker provides earth-leakage protection for AC 50/60 Hz installations. It is available in Type AC, Type A and high-immunity Type ASi versions, with 16-100 A ratings, 10-300 mA sensitivities, and 2P or 4P configurations. Designed for 35 mm DIN-rail mounting, it includes voltage-independent magnetic operation, a fault-current indicator and top or bottom power entry.

Rated Current
16-100 A
Residual Current
10 mA (16-40 A); 30, 100, 300 mA
Pole Configuration
2P, 4P
RCCB Type
AC, A, ASi

Overview

The VKL11 is a residual current circuit breaker for residual-current protection in AC 50/60 Hz electrical installations. It disconnects the circuit when earth leakage is detected and is available in Type AC, Type A and high-immunity Type ASi versions. The range covers rated currents from 16 A to 100 A, residual operating currents from 10 mA to 300 mA, and 2P or 4P configurations rated at 240 V AC or 415 V AC. Designed for residential, commercial and industrial distribution systems, it mounts on a 35 mm DIN rail and is intended for use with suitable overload and short-circuit protection.

Features

  • Compliant with IEC/EN 61008-1.
  • Type AC, Type A and high-immunity Type ASi versions.
  • Voltage-independent magnetic operation.
  • Integrated fault-current indicator.
  • Rated-current options from 16 A to 100 A.
  • Top or bottom power entry.

Models

Type Detectable residual current Time characteristic Recommended applications
Type AC Sinusoidal AC residual current Instantaneous Conventional AC circuits and resistive loads
Type A Sinusoidal AC and pulsating DC residual currents Instantaneous Residential, commercial and electronic equipment circuits
Type ASi Type A characteristics with enhanced immunity to nuisance tripping Short-time delayed Circuits affected by harmonics, transient surges or electronic equipment

Specifications

Electrical Data

Parameter Specification
Rated current 16, 25, 32, 40, 63, 80, 100 A
Rated residual operating current 10 mA (16-40 A); 30, 100, 300 mA
Rated voltage 240 V AC (2P); 415 V AC (4P)
Rated frequency 50/60 Hz
Rated residual making and breaking capacity 500 A (16-40 A); 630 A (63 A); 800 A (80 A); 1,000 A (100 A)
Rated conditional short-circuit current 6/10 kA
Rated insulation voltage 500 V
Rated impulse withstand voltage 6 kV
Dielectric test voltage 2.5 kV for 1 minute

Protection Data

Parameter Specification
Residual current type AC, A, ASi
Tripping characteristic Instantaneous; short-time delayed for ASi
Number of poles 2P, 4P
Fault-current indicator Yes
Degree of protection IP20

Mechanical Data

Parameter Specification
Electrical life ≥2,000 operations
Mechanical life ≥2,000 operations

Installation Data

Parameter Specification
Mounting 35 mm DIN rail, EN 60715
Terminal connection Cable or pin-type busbar
Terminal capacity Up to 35 mm²
Tightening torque 2.5 N·m
Power entry Top or bottom

Environmental and Standards Data

Parameter Specification
Operating temperature -25°C to +55°C
Storage temperature -40°C to +70°C
Pollution degree 2
Compliant standard IEC/EN 61008-1

Selection Guide

Code position Meaning Catalog value or options
V VIOX enterprise identification V
KL RCCB product family code KL
11 Design serial number 11
AC / A / ASi Residual current type AC, A or ASi
Rated-current code Rated current 16, 25, 32, 40, 63, 80 or 100 A
Residual-current code Rated residual operating current 10, 30, 100 or 300 mA
2P / 4P Number of poles 2P or 4P

Residual Current Type

Select Type AC for sinusoidal AC residual current, Type A for sinusoidal AC and pulsating DC residual currents, or Type ASi when enhanced immunity and short-time-delayed operation are required.

Rated Current

Choose one of the listed ratings from 16 A to 100 A to match the circuit rating.

Sensitivity

Select 10, 30, 100 or 300 mA according to the required protection application. The 10 mA option is listed for 16-40 A ratings.

Poles and Voltage

Select 2P for 240 V AC or 4P for 415 V AC installations.

Dimensions

VKL11 Type A, Type AC and Type ASi RCCB dimensional drawing
VKL11 2P and 4P RCCB dimensional drawing.

Applications

  • 10 mA sensitivity for sensitive equipment and locations requiring enhanced personal protection.
  • 30 mA sensitivity for additional protection against electric shock.
  • 100 mA sensitivity for protection against indirect contact.
  • 300 mA sensitivity for protection against insulation-fault fire risks.

Installation

  • Mount the selected RCCB on a 35 mm DIN rail in accordance with EN 60715.
  • Use cable or a pin-type busbar within the listed terminal capacity of up to 35 mm².
  • Apply the listed terminal tightening torque of 2.5 N·m.
  • Power entry may be made from the top or bottom.
  • Use the RCCB together with suitable overload and short-circuit protection.

FAQ

Which residual current types are available for the VKL11?

The VKL11 is available in Type AC, Type A and Type ASi versions.

Which rated currents and sensitivities are offered?

Rated currents are 16, 25, 32, 40, 63, 80 and 100 A. Residual operating-current options are 10 mA for 16-40 A ratings and 30, 100 or 300 mA.

Which voltage applies to each pole configuration?

The 2P configuration is rated at 240 V AC, while the 4P configuration is rated at 415 V AC.

Does the VKL11 provide overload and short-circuit protection?

The catalog specifies that the VKL11 is intended for use together with suitable overload and short-circuit protection.

How can the VKL11 terminals be connected?

The terminals accept cable or a pin-type busbar, with a listed capacity of up to 35 mm² and a tightening torque of 2.5 N·m.

Which standard is listed for the VKL11?

The catalog lists IEC/EN 61008-1 as the compliant standard.