VIOX Electric
Language

VKL11-EV Electric Vehicle Residual Current Circuit Breaker

The VIOX VKL11-EV residual current circuit breaker series is designed for Mode 3 electric vehicle charging installations. VKL11A-EV provides instantaneous Type A EV protection, while VKL11F-EV adds mixed-frequency residual-current detection and short-time-delayed tripping. Both versions detect sinusoidal AC, pulsating DC and smooth DC residual currents with a maximum 6 mA DC tripping threshold, in 16-100 A and 2P or 4P configurations.

Rated Current
16-100 A
Residual Current
A-EV: 10-300 mA; F-EV: 30 mA
DC Threshold
6 mA
Pole Configuration
2P, 4P

Overview

The VKL11-EV series comprises residual current circuit breakers designed for Mode 3 electric vehicle charging installations. VKL11A-EV provides instantaneous Type A EV protection for standard wall boxes and charging stations, while VKL11F-EV adds mixed-frequency residual-current detection and short-time-delayed operation. Both versions detect sinusoidal AC and pulsating DC residual currents and switch off at a maximum smooth DC threshold of 6 mA. The range covers rated currents from 16 A to 100 A in 2P and 4P configurations. Suitable overload and short-circuit protection must be installed separately.

Features

  • Two EV protection versions: VKL11A-EV Type A EV and VKL11F-EV Type F EV.
  • Sinusoidal AC, pulsating DC and 6 mA smooth DC residual-current detection.
  • Available in 2P and 4P configurations from 16 A to 100 A.
  • Rated impulse withstand voltage of 6 kV.
  • IP20 protection with an integrated fault-current indicator.
  • Top or bottom power entry.

Models

Variant Product type Rated residual operating current Tripping characteristic Residual-current detection
VKL11A-EV Type A EV RCCB 10 mA for 2P/4P 16-40 A versions; 30, 100, 300 mA Instantaneous Sinusoidal AC, pulsating DC and smooth DC switch-off at a maximum threshold of 6 mA
VKL11F-EV Type F EV RCCB 30 mA Short-time delayed Sinusoidal AC, pulsating DC, mixed-frequency residual current and smooth DC switch-off at a maximum threshold of 6 mA

Specifications

Electrical Data

Parameter Specification
Rated current (In) 16, 25, 32, 40, 63, 80, 100 A
Rated voltage (Ue) 2P: 240 V AC; 4P: 415 V AC
Rated frequency 50/60 Hz
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 6 kV (1.2/50 μs)
Dielectric test voltage 2.5 kV for 1 minute
Rated conditional short-circuit current (Inc/IΔc) 6 kA, 10 kA
Pollution degree 2

Making and Breaking Data

Rated current Rated residual making and breaking capacity (IΔm) VKL11F-EV additional ratings
16, 25, 32, 40 A 500 A Im: 1,500 A; peak withstand current: 3 kA (8/20 μs)
63 A 630 A Im: 1,500 A; peak withstand current: 3 kA (8/20 μs)
80 A 800 A Im: 1,500 A; peak withstand current: 3 kA (8/20 μs)
100 A 1,000 A Im: 1,500 A; peak withstand current: 3 kA (8/20 μs)

Protection Data

Parameter Specification
Sinusoidal AC residual current Detected
Pulsating DC residual current Detected
Smooth DC tripping threshold 6 mA
Smooth DC residual current Switch-off at a maximum threshold of 6 mA
Fault-current indicator Yes
Degree of protection IP20

Mechanical Data

Parameter Specification
Electrical endurance ≥2,000 operating cycles
Mechanical endurance ≥2,000 operating cycles

Installation Data

Parameter Specification
Terminal connection type Cable/pin-type busbar
Cable terminal capacity 25-35 mm²; 18-3/18-2 AWG
Busbar terminal capacity 10/16 mm²; 18-8/18-5 AWG
Terminal tightening torque 2.5 N·m; 22 in-lb
Mounting 35 mm DIN rail according to EN 60715, with fast-clip device
Power entry Top or bottom

Environmental and Standards Data

Parameter Specification
Ambient temperature -25°C to +55°C, with daily average ≤35°C
Storage temperature -40°C to +70°C
VKL11A-EV standards IEC/EN 61008-1, IEC 62955
VKL11F-EV standards IEC/EN 61008-1, EN 62423, OVE E8601

Selection Guide

Code position Meaning Catalog value or options
V VIOX enterprise identification V
KL RCCB product family code KL
11 Design serial number 11
A-EV / F-EV Residual-current protection type A-EV or F-EV
Rated-current code Rated current 16, 25, 32, 40, 63, 80 or 100 A
Residual-current code Rated residual operating current VKL11A-EV: 10 mA for 16-40 A versions, or 30, 100 and 300 mA; VKL11F-EV: 30 mA
2P / 4P Number of poles 2P or 4P

Protection Version

Select VKL11A-EV for instantaneous Type A EV protection or VKL11F-EV for mixed-frequency detection with short-time-delayed operation.

Rated Current

Choose one of the listed ratings from 16 A to 100 A to match the charging circuit rating.

Sensitivity

For VKL11A-EV, select 10 mA for 16-40 A versions or 30, 100 or 300 mA. VKL11F-EV is listed with 30 mA sensitivity.

Poles and Voltage

Select 2P for 240 V AC or 4P for 415 V AC charging installations.

Trip Curves

Characteristic VKL11A-EV VKL11F-EV
Rated residual operating current (IΔn) 10 mA for 2P/4P 16-40 A versions; 30, 100, 300 mA 30 mA
Smooth DC tripping threshold 6 mA 6 mA
Mixed-frequency residual current Detected according to Type F / EN 62423
Tripping time Instantaneous Short-time delayed
Break time at IΔn ≤100 ms (normal type) 10-300 ms (G type)

Dimensions

VKL11-EV electric vehicle RCCB dimensional drawing
VKL11-EV 2P and 4P RCCB dimensional drawing.

Applications

  • Mode 3 electric vehicle charging installations.
  • Standard EV wall boxes using VKL11A-EV instantaneous protection.
  • EV charging stations using VKL11A-EV Type A EV protection.
  • EV charging circuits with mixed-frequency leakage currents using VKL11F-EV.

Installation

  • Install the RCCB together with suitable overload and short-circuit protection.
  • Mount the device on a 35 mm DIN rail according to EN 60715 using the fast-clip device.
  • Use cable or a pin-type busbar within the listed terminal capacities.
  • Apply the listed terminal tightening torque of 2.5 N·m or 22 in-lb.
  • Power entry may be made from the top or bottom.

FAQ

What is the VKL11-EV series designed for?

It is designed for Mode 3 electric vehicle charging installations.

What is the difference between VKL11A-EV and VKL11F-EV?

VKL11A-EV provides instantaneous Type A EV protection. VKL11F-EV adds mixed-frequency residual-current detection and short-time-delayed tripping.

What is the smooth DC tripping threshold?

Both versions switch off at a maximum smooth DC residual-current threshold of 6 mA.

Which rated currents and pole configurations are available?

The series covers 16, 25, 32, 40, 63, 80 and 100 A in 2P and 4P configurations.

Does the VKL11-EV provide overload and short-circuit protection?

The catalog specifies that the RCCB must be installed together with suitable overload and short-circuit protection.

Which standards are listed for each version?

VKL11A-EV lists IEC/EN 61008-1 and IEC 62955. VKL11F-EV lists IEC/EN 61008-1, EN 62423 and OVE E8601.

Need a Product Quote?
Let’s Build It Together.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Request a Quote