RCCB Manufacturer & OEM Supplier

Residual Current Circuit Breakers (RCCB)

Compare VIOX RCCB series for conventional AC, pulsating DC, mixed-frequency, smooth-DC and EV charging applications. Published models cover 16–100A ratings in 2P and 4P configurations.

  • Type AC, A, ASi, F, B, B+ and EV variants
  • Model-specific datasheets and documentation review
  • OEM marking, packaging and wholesale supply
VKL11 Residual Current Circuit Breaker
4Published series
16–100ARated-current range
2P / 4PPole configurations
AC → EVApplication-specific coverage

Choose by residual-current type

Which RCCB series should you start with?

Begin with the residual-current waveform and application, then confirm rated current, IΔn, poles, voltage and upstream overcurrent protection.

01General-purpose protection
VKL11 Residual Current Circuit Breaker

VKL11

Start here for conventional AC or pulsating-DC residual-current protection in residential, commercial and distribution applications.

Type
Type AC / A / ASi
Rated current
16–100A
Poles
2P / 4P
02Mixed-frequency loads
VKL11F Type F Residual Current Circuit Breaker

VKL11F

For circuits with single-phase electronic equipment and mixed-frequency residual currents up to the model’s declared operating range.

Type
Type F
Rated current
16–100A
Poles
2P / 4P
03Smooth DC & high frequency
VKL11B Type B/B+ Residual Current Circuit Breaker

VKL11B

For installations where smooth DC and higher-frequency residual currents must be detected, subject to the exact system and model requirements.

Type
Type B / B+
Rated current
16–100A
Poles
2P / 4P
04Mode 3 EV charging
VKL11-EV Electric Vehicle Residual Current Circuit Breaker

VKL11-EV

For Mode 3 EV charging, with Type A or Type F residual-current protection and integrated smooth-DC detection that switches off at a maximum 6mA threshold for the declared variants.

Type
Type A EV / F EV
Rated current
16–100A
Poles
2P / 4P

Interactive specification builder

VIOX RCCB Selector

Describe the supply system, connected load and protection objective. The selector builds a preliminary RCCB specification, identifies a candidate VIOX series and lists every item that still needs verification.

Question 1 of 10
Which market or standard applies?

Use the project requirement when it is already known.

Is the circuit single-phase or three-phase?

This provides a preliminary 2P or 4P direction.

What is the working voltage?

Choose the declared circuit voltage, not an assumed regional value.

What is the main application?

The connected equipment determines the residual-current waveform that must be detected.

Does the load use an inverter, rectifier or electronic speed control?

Examples include VFDs, inverter-driven compressors and power-electronic equipment.

Can the equipment produce smooth DC residual current?

Check the equipment manufacturer’s protective-device requirements before answering.

For EV charging, is 6mA DC detection already provided?

Select “Not applicable” when this is not an EV charging circuit.

What current ratings are being considered?

RCCB rated current and upstream overcurrent protection must be coordinated separately.

What is the main protection objective?

This guides the IΔn discussion; local rules and the project design remain controlling.

Is there another RCD upstream?

An upstream RCD can create time-delay and selectivity requirements.

Looking for a 63A configuration? Compare 63 amp RCCB types, poles and sensitivities.

Model-level comparison

Compare VKL11, VKL11F, VKL11B and VKL11-EV

Use the table to shortlist a series. Verify the exact rating combination and destination-market documents before ordering.

SeriesRCCB typeRated currentRated residual currentPolesRated voltagePublished standards
VKL11General-purpose protectionType AC / A / ASi16–100A10mA* / 30mA / 100mA / 300mA2P / 4P240V / 415V ACIEC/EN 61008-1
VKL11FMixed-frequency loadsType F16–100A30mA / 100mA / 300mA2P / 4P230/240V / 400/415V ACIEC/EN 62423 · IEC/EN 61008-1
VKL11BSmooth DC & high frequencyType B / B+16–100AB: 30–500mA · B+: 30–300mA2P / 4P230/240V / 400/415V ACType B: IEC/EN 62423 + IEC/EN 61008-1 · Type B+: confirm DIN VDE 0664-400 for the exact variant
VKL11-EVMode 3 EV chargingType A EV / F EV16–100AA-EV: 10–300mA · F-EV: 30mA2P / 4P240V / 415V ACA-EV: IEC/EN 61008-1 + IEC 62955 · F-EV: IEC/EN 61008-1 + EN 62423 + OVE E 8601

* The 10mA VKL11 option applies to published 16–40A configurations. IEC 62423 covers Type F and Type B; a Type B+ claim must be confirmed against the exact variant and applicable DIN VDE 0664-400 evidence. The VKL11-EV catalog lists IEC 62955 for VKL11A-EV, while VKL11F-EV is listed with EN 62423 and OVE E 8601. Confirm the ordered variant and supporting documents.

OEM and wholesale RCCB procurement

For OEM or wholesale purchasing, use the manufacturer page to review model documents, marking, packaging and order approval. Keep product selection here, then confirm your chosen configuration and commercial requirements with VIOX.

RCCB manufacturer — OEM & wholesale supply

Application guide

Match the RCCB series to the load profile.

Start with the connected equipment and expected residual-current waveform. Then verify the required type, sensitivity, poles, voltage and overcurrent coordination.

Electrical distribution panels for general RCCB applications
VKL11

General Distribution

Residential, commercial and panel-distribution circuits requiring the appropriate Type AC, A or ASi variant.

View VKL11
Engineer inspecting a variable-frequency-drive control cabinet for an industrial pump system
VKL11F

Electronic & Variable-Frequency Loads

Single-phase drives, heat pumps, HVAC and electronic equipment that may produce mixed-frequency residual currents.

View VKL11F
Solar photovoltaic and battery energy storage installation
VKL11B

Power Conversion Systems

PV, battery storage, UPS and drive applications where the system requires smooth-DC residual-current detection.

View VKL11B
Electric vehicle connected to a charging point
VKL11-EV

Mode 3 EV Charging

Residential and commercial Mode 3 charging points requiring a declared A-EV or F-EV configuration.

View VKL11-EV

Why RCCBs Fail or Nuisance-Trip in Distribution Boards — And How VIOX Engineers Around It

Most RCCB field failures trace back to four predictable misapplications: missing backup protection, DC core blinding, cumulative group leakage, or missing upstream selectivity.

01Backup Rating

Missing Overcurrent Backup Coordination

An RCCB alone cannot interrupt short circuits; exceeding its thermal current (In) or conditional short-circuit rating (Inc) welds contacts.

VIOX EngineeringPair VKL11 RCCBs with coordinated VIOX MCBs or fuses verified to Inc ratings.
02DC Blinding

Smooth DC Faults Blind Type A Toroids

EV chargers and 3-phase inverters leaking > 6 mA smooth DC saturate standard Type A magnetic cores, leaving the circuit unprotected.

VIOX EngineeringSpecify VKL11-EV (6 mA DC EVSE) or full Type B VKL11B (IEC 62423) for DC-capable circuits.
03Group Leakage

Cumulative Standing Leakage Nuisance Trips

Grouping too many LED drivers, IT power supplies, or inverter drives behind one 30 mA Type A RCCB pushes normal leakage past trip threshold.

VIOX EngineeringUse VKL11F Type F for inverter loads, or split critical branches onto individual RCBOs.
04Selectivity

Upstream & Downstream Simultaneous Tripping

Installing two instantaneous 30 mA RCCBs in series causes both main and branch breakers to trip together during a single earth fault.

VIOX EngineeringCoordinate upstream 100/300 mA fire-protection RCCBs with downstream 30 mA final protection.

RCCB Application → Series Decision Matrix (With Engineering Limits)

Select the exact VKL11 platform for your fault waveform and load profile—including explicit boundaries where an RCCB alone is not suitable.

Application-based RCCB selection matrix with engineering limits and pre-order verification
Application / Load Profile Recommended VIOX Series Type & Sensitivity Engineering Limits / Not Suitable For Pre-Order Verification
Residential & Commercial Split-Load Boards VKL11 Type AC / A · 30 / 100 / 300 mA No overload or short-circuit trip—must coordinate with upstream/downstream MCB. Verify RCCB In ≥ sum of downstream MCBs or main incomer rating.
Single-Phase Inverter HVAC, Pumps & Appliances VKL11F Type F · 30 mA / 100 mA Handles composite frequencies up to 1 kHz; not rated for > 6 mA smooth DC EV faults. Confirm inverter harmonic leakage and 2P vs 4P pole requirement.
AC EV Charging Stations (Mode 3 EVSE) VKL11-EV Type A + 6 mA DC · 30 mA Dedicated to AC EVSE circuits; pair with dedicated overcurrent MCB per charging point. Confirm IEC 62955 compliance and rated current (32 A / 40 A / 63 A).
3-Phase VFDs, Solar Inverters & Industrial Drives VKL11B Type B · 30 / 100 / 300 mA Verify whether upstream fire-protection requires 300 mA vs 30 mA personal protection. Confirm 3-phase smooth DC fault path and IEC 62423 requirement.
Single-Device Leakage + Overcurrent Protection Upgrade to VIOX RCBO IEC 61009-1 · VRL Family Do not use an RCCB where space or code requires independent circuit overload + earth-leakage isolation. Confirm DIN module width and individual circuit tripping requirements.

Before placing an order

Turn the circuit requirement into a checkable RCCB specification.

An RCCB should not be chosen from one headline rating. Record the complete electrical requirement and match it to the exact published model.

Open the complete RCCB selection guide
  1. 01

    Confirm system voltage and conductors

    Define the single-phase or three-phase circuit, neutral arrangement and required 2P or 4P switching.

  2. 02

    Set rated current and IΔn

    State both the continuous-current rating and the required residual operating current.

  3. 03

    Match the residual-current waveform

    Use the connected equipment manufacturer’s requirements to select Type AC, A, F, B, B+ or an EV variant.

  4. 04

    Coordinate overcurrent protection

    Confirm the MCB, fuse or other overcurrent device because an RCCB does not provide overload or short-circuit protection.

  5. 05

    Verify the exact document set

    Match the model, rating, standard, destination market, certificate request and OEM artwork before production.

How VIOX RCCBs Compare Across IEC 61008-1 Performance Tiers

Benchmark the VKL11, VKL11F, VKL11B, and VKL11-EV series against global Tier-1 specification tiers across standard, inverter, and EV/industrial earth-leakage protection.

IEC 61008-1 specification tier benchmark between global Tier-1 lines and VIOX RCCB series
Specification Tier Global Tier-1 Reference Tier VIOX Equivalent Series Commercial & Delivery Delta
Standard Type AC / A RCCB Global Tier-1 Standard 2P / 4P IEC 61008-1 RCCB VKL11 (2P / 4P, Type AC / A) Factory-direct wholesale economics with standard 18 mm/pole DIN-rail fit.
Type F High-Immunity RCCB Global Tier-1 Type F Inverter-Duty RCCB VKL11F (2P / 4P, Type F) Faster factory replenishment on VFD/HVAC projects vs. long specialty lead times.
Type B & EVSE 6 mA DC RCCB Global Tier-1 Type B / EVSE RCCB VKL11B & VKL11-EV Substantial BOM savings for EV charger OEMs, solar EPCs, and industrial panels.
OEM Private-Label Branding Not offered to independent regional distributors Full OEM Laser Logo + Color Box Private-label production backed by IEC 61008-1 / 62423 baseline verification.

Where This Lands Honestly

If your project tender legally locks you into a sole-source multinational Approved Vendor List (AVL) with zero approved equivalents, keep the specified legacy brand. Where IEC 61008-1 / IEC 62423 / IEC 62955 compliance governs—especially on EV charging boards, solar inverters, and regional distributor programs—the VKL11 family delivers standard DIN-rail compatibility, verified residual-current curves, and significantly better margin and supply responsiveness.

RCCB Quotation Variables — What Moves Unit Pricing

Review the four engineering and packaging factors that determine an RCCB factory quotation before submitting your panel BOM or distributor order list.

4 engineering and packaging variables that move an RCCB factory quotation
Pricing Variable Standard Baseline Higher-Spec / OEM Configuration Impact on Unit Quote
1. Residual Detection Type Type AC / Type A (VKL11) Type F (VKL11F), EV 6 mA DC (VKL11-EV), or Type B (VKL11B) Type B and EV detection add active DC sensing circuitry
2. Pole Count & Rated Current 2P 25 A–63 A (high-volume standard) 4P 63 A–100 A high-current frames Scales with pole count, copper conductor mass, and contact size
3. Sensitivity & Compliance 30 mA / 100 mA / 300 mA + IEC 61008-1 & CE IEC 62423 / IEC 62955 / CB / TUV / OEM co-listing Baseline included on certified series; lab co-listing billed at cost
4. OEM Marking & Packaging VIOX brand or neutral export inner box Custom laser logo, bespoke color box, EAN barcodes, multilingual leaflet Laser marking supported on batch runs; print setup amortized by volume

Planning an OEM Private-Label or Bulk Wholesale RCCB Program?

Review dedicated RCCB assembly and calibration lines, OEM packaging options, and compliance transfer dossiers on our RCCB Manufacturer page.

RCCB OEM Manufacturer Program →

Manufacturer & OEM support

Qualify the product and the supply process.

VIOX supports distributors, panel builders and private-label electrical brands with published model data, sample approval and order-specific documentation review.

RCCB Selection & Procurement Questions

Direct engineering and sourcing answers on RCCB vs RCBO, Type A vs F vs B vs EV, upstream MCB coordination, and OEM supply.

Does an RCCB provide overload or short-circuit protection? Safety Boundary

No. An RCCB (IEC 61008-1) detects earth-leakage residual current only. It must always be coordinated with an upstream or downstream MCB or fuse rated within the RCCB’s conditional short-circuit capacity (Inc).

If you need combined earth-leakage, overload, and short-circuit protection in a single device, specify a VIOX RCBO instead.

What is the difference between VKL11B (Type B) and VKL11-EV? EV / Solar

VKL11B is a full Type B RCCB (IEC 62423) for industrial three-phase variable-speed drives, solar inverters, and mixed DC/high-frequency leakage loads.

VKL11-EV is engineered specifically for AC EV charging stations, combining Type A detection with dedicated 6 mA smooth DC fault disconnection per IEC 62955.

When should I upgrade from Type A (VKL11) to Type F (VKL11F)? Inverter Loads

Upgrade to VKL11F whenever a distribution group feeds single-phase inverter HVAC, heat pumps, or variable-speed appliances that generate composite frequencies up to 1 kHz and cause nuisance tripping on standard Type A units.

How do I select between 30 mA, 100 mA, and 300 mA RCCB sensitivity? Sensitivity

Use 30 mA for direct/indirect personal shock protection on final circuits and EV chargers. Use 100 mA or 300 mA (typically time-delayed / selective upstream) for fire protection on main feeders and sub-distribution boards.

Are VIOX VKL11 series RCCBs mechanically compatible with standard 35 mm DIN-rail panels? Compatibility

Yes. All VKL11, VKL11F, VKL11B, and VKL11-EV RCCBs follow standard 18 mm-per-pole modular geometry and EN 60715 (TS35) 35 mm DIN-rail mounting for direct integration in IEC distribution boards.

How do engineering samples and OEM private-label RCCB orders work? OEM / Samples

VIOX supports low-MOQ engineering sample orders for bench testing and panel mockup approval. For private-label laser branding, custom cartons, and CB/TUV co-listing dossiers, review our RCCB OEM Manufacturer Program.

Ready for model review?

Send one complete RCCB requirement.

Include voltage, current, poles, RCCB type, IΔn, quantity, destination market, required documents and OEM details. VIOX will review the closest published series.

Request RCCB datasheets & quote