MCBs, RCCBs and RCBOs for residential distribution boards. Find the protection families for your project, compare VIOX series and prepare a clear product request.

Explore protection products
Residential buildings with rooftop solar and electrical infrastructure
Residential distribution & circuit protection

Start with the protection each circuit needs.

For panel builders, electrical contractors and distributors: organize the protection functions first, then confirm the exact devices against the supply system, loads and destination-market requirements.

Explore the protection families

VOB3-63 ミニチュア回路遮断器

Overload & short-circuit protection

VOB3-63 ミニチュア回路遮断器

Choose the current rating, tripping curve, pole configuration and breaking capacity for each circuit. An MCB does not provide residual-current protection.

VKL11 漏電遮断器

残留電流保護

VKL11 漏電遮断器

Use with coordinated overcurrent protection. Select the residual-current type for the connected equipment; Type B and EV variants are not a default requirement for every home.

VRL22 Type A/AC/ASi RCBO

複合回路保護

VRL22 Type A/AC/ASi RCBO

Combine residual-current and overcurrent protection at the circuit level. Separating final circuits can limit disruption from a fault; continuity still depends on upstream coordination.

Protection options, not a wiring diagram or three devices to install in sequence. The supply system, loads and installation rules determine the final arrangement.

Other protection needs?

サージ保護装置 address transient overvoltages; they do not replace circuit breakers. Arc fault detection devices address specified arc-fault risks where required by the project and local rules. Main isolation and load-control devices must be selected separately for their duties.

Different loads. Different checks.

A lighting circuit and an inverter-driven appliance do not present the same selection questions. Use the equipment instructions alongside the circuit design.

Lighting & socket outlets
Check design load, conductor protection, switching inrush and the required residual-current protection.
Kitchens, water heating & outdoor circuits
Confirm dedicated-circuit needs, installation conditions, isolation and the applicable electric-shock protection measures.
Air conditioning & heat pumps
Check inverter characteristics and the equipment manufacturer’s specified RCD type. Do not select from appliance power alone.
EV charging, rooftop PV & storage
Confirm the equipment’s DC residual-current detection and protection requirements. Type B or EV-specific devices are candidates only where the system requires them; AC-side protection does not specify a PV or battery DC circuit.

Bring the project details. Build a clearer product request.

Send an existing schedule or share the information below. If a value is not confirmed, flag it for review instead of selecting a rating by guesswork.

Match product standards, installation rules and market approvals to the exact model and application. Request the relevant model documents before order approval.

Review model-document support
Market & documents
Destination country, project standard and required certificates or reports.
Supply & installation
Voltage, frequency, phases, earthing system and available short-circuit current.
Circuits & protection
Load schedule, conductor and installation details, RCD type, sensitivity and upstream protection.
デバイスの構成
Series, current, poles, trip curve, short-circuit rating and neutral-switching requirements.
Order scope
Quantities, board-space limits, branding and packaging requirements.

Planning a residential project or product range?

Share your circuit schedule or sourcing requirements with VIOX.