モジュラー接触器メーカー (BMC7 & BCH8 DIN-Rail · 16–100 A · IEC 61095)

Factory-direct hum-free IEC 61095 DIN-rail modular contactors across BMC7 (16–63 A, 1P–4P), BCH8 (16–100 A), and BCH8-M Manual Override (16M–63M)—paired with clip-on 1NO+1NC / 2NO auxiliary blocks and 9 mm thermal spacers.

16 A – 100 A16–63 A Full Codes · 100 A (2NO/4NO)
1P / 2P / 3P / 4PFull NO, NC & Mixed (/11, /22, /31)
BCH8-M + 9 mm SpacerManual Off/Auto/On & Aux Blocks
VIOX BMC7 and BCH8 DIN-rail modular contactors lineup

VIOX BMC7, BCH8 & BCH8-M Published Catalog

BCH8-25 2P モジュラーコンタクタ
BCH8 · Silent DIN-Rail

BCH8-25 (2P)

BCH8-25 2P モジュラーコンタクタ

AC-7a / AC-7b
25 A (AC-7b: 8.5 A)
ポール
2P
DIN Width
18 mm (1 Mod)
Contact Codes
/20 · /11 · /02
BCH8-25 4P モジュラーコンタクタ
BCH8 · Silent DIN-Rail

BCH8-25 (4P)

BCH8-25 4P モジュラーコンタクタ

AC-7a / AC-7b
25 A (AC-7b: 8.5 A)
ポール
4P
DIN Width
36 mm (2 Mod)
Contact Codes
/40 · /31 · /22 · /04
BCH8-63 2P モジュラーコンタクタ
BCH8 · High-Load

BCH8-63 (2P)

BCH8-63 2P モジュラーコンタクタ

AC-7a / AC-7b
63 A (AC-7b: 25–30 A)
ポール
2P
DIN Width
36 mm (2 Mod)
Contact Codes
/20 · /11 · /02
BCH8-63 4Pモジュラコンタクタ
BCH8 · High-Load

BCH8-63 (4P)

BCH8-63 4Pモジュラコンタクタ

AC-7a / AC-7b
63 A (AC-7b: 25–30 A)
ポール
4P
DIN Width
54 mm (3 Mod)
Contact Codes
/40 · /31 · /22 · /04
BCH8-100 2P モジュラーコンタクタ
BCH8 · 100A Heavy

BCH8-100 (2P)

BCH8-100 2P モジュラーコンタクタ

AC-7a / AC-7b
100 A (AC-7b: 35–40 A)
ポール
2P
DIN Width
54 mm (3 Mod)
Contact Codes
/20 (2NO only)
BCH8-100 4P モジュラーコンタクタ
BCH8 · 100A Heavy

BCH8-100 (4P)

BCH8-100 4P モジュラーコンタクタ

AC-7a / AC-7b
100 A (AC-7b: 35–40 A)
ポール
4P
DIN Width
54 mm (3 Mod)
Contact Codes
/40 (4NO only)
BCH8-25M 2P モジュラーコンタクタ
Manual Off/Auto/On

BCH8-25M (2P)

BCH8-25M 2P モジュラーコンタクタ

AC-7a / AC-7b
25 A (AC-7b: 8.5 A)
ポール
2P
DIN Width
18 mm + Lever
Contact Codes
/20 · /11 · /02
BCH8-25M 4P モジュラーコンタクタ
Manual Off/Auto/On

BCH8-25M (4P)

BCH8-25M 4P モジュラーコンタクタ

AC-7a / AC-7b
25 A (AC-7b: 8.5 A)
ポール
4P
DIN Width
36 mm + Lever
Contact Codes
/40 · /31 · /22
BCH8-63M 2P モジュラーコンタクタ
Manual Off/Auto/On

BCH8-63M (2P)

BCH8-63M 2P モジュラーコンタクタ

AC-7a / AC-7b
63 A (AC-7b: 25–30 A)
ポール
2P
DIN Width
36 mm + Lever
Contact Codes
/20 · /11 · /02
BCH8-63M 4Pモジュラコンタクタ
Manual Off/Auto/On

BCH8-63M (4P)

BCH8-63M 4Pモジュラコンタクタ

AC-7a / AC-7b
63 A (AC-7b: 25–30 A)
ポール
4P
DIN Width
54 mm + Lever
Contact Codes
/40 · /31 · /22
BMC7-16 2P モジュラーコンタクタ
BMC7 · 66-Code Series

BMC7-16 (2P)

BMC7-16 2P モジュラーコンタクタ

AC-7a / AC-7b
16 A (AC-7b: 6 A)
ポール
2P
DIN Width
18 mm (1 Mod)
Contact Codes
/20 · /11 · /02
BMC7-16 4Pモジュラコンタクタ
BMC7 · 66-Code Series

BMC7-16 (4P)

BMC7-16 4Pモジュラコンタクタ

AC-7a / AC-7b
16 A (AC-7b: 6 A)
ポール
4P
DIN Width
36 mm (2 Mod)
Contact Codes
/40 · /31 · /22 · /04
BMC7-20 2P モジュラーコンタクタ
BMC7 · 66-Code Series

BMC7-20 (2P)

BMC7-20 2P モジュラーコンタクタ

AC-7a / AC-7b
20 A (AC-7b: 7 A)
ポール
2P
DIN Width
18 mm (1 Mod)
Contact Codes
/20 · /11 · /02
BMC7-20 4P モジュラーコンタクタ
BMC7 · 66-Code Series

BMC7-20 (4P)

BMC7-20 4P モジュラーコンタクタ

AC-7a / AC-7b
20 A (AC-7b: 7 A)
ポール
4P
DIN Width
36 mm (2 Mod)
Contact Codes
/40 · /31 · /22 · /04
BMC7-25 2P モジュラーコンタクタ
BMC7 · 66-Code Series

BMC7-25 (2P)

BMC7-25 2P モジュラーコンタクタ

AC-7a / AC-7b
25 A (AC-7b: 8.5 A)
ポール
2P
DIN Width
18 mm (1 Mod)
Contact Codes
/20 · /11 · /02
BMC7-25 4P モジュラーコンタクタ
BMC7 · 66-Code Series

BMC7-25 (4P)

BMC7-25 4P モジュラーコンタクタ

AC-7a / AC-7b
25 A (AC-7b: 8.5 A)
ポール
4P
DIN Width
36 mm (2 Mod)
Contact Codes
/40 · /31 · /22 · /04
BMC7-32 2P モジュラーコンタクタ
BMC7 · 66-Code Series

BMC7-32 (2P)

BMC7-32 2P モジュラーコンタクタ

AC-7a / AC-7b
32 A (AC-7b: 11 A)
ポール
2P
DIN Width
36 mm (2 Mod)
Contact Codes
/20 · /11 · /02
BMC7-32 4Pモジュラコンタクタ
BMC7 · 66-Code Series

BMC7-32 (4P)

BMC7-32 4Pモジュラコンタクタ

AC-7a / AC-7b
32 A (AC-7b: 11 A)
ポール
4P
DIN Width
54 mm (3 Mod)
Contact Codes
/40 · /31 · /22 · /04
BMC7-40 2Pモジュラコンタクタ
BMC7 · 66-Code Series

BMC7-40 (2P)

BMC7-40 2Pモジュラコンタクタ

AC-7a / AC-7b
40 A (AC-7b: 15 A)
ポール
2P
DIN Width
36 mm (2 Mod)
Contact Codes
/20 · /11 · /02
BMC7-40 4Pモジュラコンタクタ
BMC7 · 66-Code Series

BMC7-40 (4P)

BMC7-40 4Pモジュラコンタクタ

AC-7a / AC-7b
40 A (AC-7b: 15 A)
ポール
4P
DIN Width
54 mm (3 Mod)
Contact Codes
/40 · /31 · /22 · /04
BMC7-63 2P モジュラーコンタクタ
BMC7 · 66-Code Series

BMC7-63 (2P)

BMC7-63 2P モジュラーコンタクタ

AC-7a / AC-7b
63 A (AC-7b: 25–30 A)
ポール
2P
DIN Width
36 mm (2 Mod)
Contact Codes
/20 · /11 · /02
BMC7-63 4Pモジュラコンタクタ
BMC7 · 66-Code Series

BMC7-63 (4P)

BMC7-63 4Pモジュラコンタクタ

AC-7a / AC-7b
63 A (AC-7b: 25–30 A)
ポール
4P
DIN Width
54 mm (3 Mod)
Contact Codes
/40 · /31 · /22 · /04

Full BMC7, BCH8, BCH8-M & Accessory Contact-Code Matrix

Complete IEC 61095 coverage from 16 A through 100 A—including hard-to-source NC and mixed contact combinations plus matched panel accessories.

Complete VIOX BMC7, BCH8, BCH8-M and accessory specification matrix
Series & Pole Format Current Ratings (AC-7a) Published Contact Codes モジュール幅 Primary Use & Boundary
BMC7 · 1P & 3P 16 / 20 / 25 / 32 / 40 / 63 A 1P: /10 (1NO), /01 (1NC) · 3P: /30 (3NO), /03 (3NC) 18 mm (1P) · 36–54 mm (3P) Single-phase lighting/heaters & 3-phase resistive feeders without neutral switching.
BMC7 · 2P & 4P 16 / 20 / 25 / 32 / 40 / 63 A 2P: /20, /11, /02 · 4P: /40, /31, /22, /04 18–36 mm (2P) · 36–54 mm (4P) Full 66-code coverage for hotels, HVAC interlocks, and fail-safe NC load shedding.
BCH8 · 1P / 2P / 3P / 4P 1P: 16–25 A · 2P–4P: 16–63 A · 2P/4P: 100 A 16–63 A: Full NO/NC/Mixed · 100 A: /20 (2NO), /40 (4NO) only 18 / 36 / 54 mm (TS35 DIN rail) Flagship silent building contactor; for heavy AC-3/AC-4 industrial motors, upgrade to CJX2s.
BCH8-M · Manual Override 16M / 20M / 25M / 40M / 63M (2P & 4P) 2P: /20, /11, /02 · 4P: /40, /31, /22 18 / 36 / 54 mm + front lever 3-position Off / Auto / On manual control for BMS maintenance & building commissioning.
Accessories (Aux & Spacer) Aux: 6 A control circuit · Spacer: passive Aux 1NO+1NC · Aux 2NO · 9 mm Thermal Spacer 9 mm side-clip Install 1× 9 mm spacer every 2–3 adjacent contactors in enclosed panels > 40 °C.
Interactive Code & AC-7a / AC-7b Selector

Configure Your Exact BMC7 / BCH8 Order Code & Check AC-7b Derating

Select your series, current, poles, and contact combination. Invalid industry combinations (such as BCH8 1P > 25 A or 100 A NC codes) are automatically guarded.

Building Panel Design Guide

Hum-Free Silent Coils, Manual Override & 9 mm Thermal Spacing

Why residential, hotel, and smart-building boards fail when engineers install noisy industrial contactors or pack modular units without convective thermal gaps.

Recommended High-Density DIN-Rail Layout (> 40 °C Enclosure) BCH8-40 4P · 54 mm BCH8-40M O·A·I 9mm SPACER BMC7-63 /22 Mixed AUX 1NO+1NC Thermal Rule: Add 1× 9 mm spacer every 2–3 loaded contactors to keep coil life intact. Flush 18 / 36 / 54 mm modular profile aligns directly with DIN-rail MCBs inside residential & hotel boards.

1. Hum-Free Silent Coils for Hotels & Living Spaces

Traditional industrial contactors emit audible 50/60 Hz magnetic hum. VIOX BMC7 & BCH8 use precision-rectified low-power coils engineered for quiet operation in bedrooms, offices, and hospital corridors.

2. BCH8-M 3-Position Manual Override (Off / Auto / On)

Available across 16M / 20M / 25M / 40M / 63M (2P & 4P), letting technicians force lighting or heating circuits ON/OFF during commissioning without rewiring BMS timers.

3. Side-Clip Aux Contacts + 9 mm Heat Spacers

Clip on 1NO+1NC または 2NO auxiliary blocks for PLC/BMS status feedback, and insert 9 mm spacers between adjacent continuous-duty contactors to prevent coil overheating.

Inside VIOX Modular Contactor Manufacturing & OEM Customization

Built for OEM electrical brands, smart-building integrators, and regional distributors who need complete contact-code depth and 100% verifiable factory quality.

01Silent QC

Silent Coil Winding & Acoustic Check

Automated copper coil winding followed by 100% pickup/drop-out checks at 85%–110% Us and hum-free acoustic screening.

OEM Custom12 V / 24 V / 48 V / 110 V / 230 V AC or silent AC/DC coils.
02Silver Alloy

AgSnO₂ / AgNi Contacts & AC-7a/7b

Arc-resistant silver-alloy contacts prevent contact welding under LED driver and HVAC compressor inrush loads.

OEM CustomFull hard-to-source NC & mixed codes (/01, /11, /02, /31, /22, /04).
03UL94 V-0

PA66 Molding & Manual Detent Test

Flame-retardant housings molded to tight 18 / 36 / 54 mm DIN tolerances with mechanical detent checks on every BCH8-M lever.

OEM CustomLaser-etched brand logo, custom faceplate wiring diagrams & EAN boxes.
04Hi-Pot & Aux

100% Dielectric Hi-Pot & Aux Fit

Every production batch passes dielectric withstand testing and side-clip alignment verification with matched auxiliary blocks.

ConsolidationShip with VIOX MCB, RCBOs & SPD on 1 PO.

VIOX BMC7 / BCH8 vs. Schneider Acti9 iCT, ABB ESB & Hager ESC

Objective cross-reference against global IEC 61095 building-contactor leaders—not heavy industrial motor contactors.

Cross-reference between Schneider Acti9 iCT, ABB ESB, Hager ESC, and VIOX BMC7/BCH8
Tier / Requirement Tier-1 Reference (Acti9 iCT / ABB ESB / Hager ESC) VIOX Equivalent Series Commercial & Customization Delta
Standard Silent 16–63 A (1P–4P) Schneider Acti9 iCT · ABB ESB20–63 · Hager ESC BMC7 & BCH8 (Full NO/NC/Mixed codes) 40%–60% lower landed cost; identical 18/36/54 mm DIN footprint
High-Current 100 A Modular Acti9 iCT 100 A · ABB ESB100 (long lead times) BCH8-100 (2P 2NO / 4P 4NO) Faster factory replenishment for commercial lighting & EV feeders
Manual Override (Off/Auto/On) Acti9 iCT Manual · Hager ETC BCH8-M (16M / 20M / 25M / 40M / 63M) Full 5-rating manual lineup + matched aux blocks & 9 mm spacers
OEM Private-Label & Mixed Codes Not offered to independent regional brands Full OEM Laser Logo + Custom Coils Build a complete modular contactor catalog under your own brand

この点についての率直な見解

If a European building tender legally specifies sole-source Schneider Acti9 iCT or ABB ESB with zero approved equivalents, keep that Tier-1 brand. Where IEC 61095 compliance governs—and you need complete 1P–4P NO/NC contact codes, 16M–63M manual override, 9 mm spacers, and 40%–60% better margin with OEM branding—VIOX BMC7 and BCH8 are engineered specifically for that role.

Modular Contactor Selection, Thermal Spacing & OEM Questions

Direct engineering answers on AC-7a/AC-7b derating, BCH8-M manual override, 9 mm spacers, Tier-1 compatibility, and mixed NO/NC contact codes.

IEC 61095 What is the difference between AC-7a and AC-7b ratings on a modular contactor?

Under IEC 61095, AC-7a covers slightly inductive or resistive loads such as electric heating, water heaters, and lighting—where a 25 A modular contactor carries the full 25 A.

AC-7b covers household and commercial motor loads (heat pumps, HVAC compressors, circulation pumps), requiring substantial derating (typically 8.5 A for a 25 A frame and 25–30 A for a 63 A frame).

Manual M When should I choose a manual-override modular contactor (BCH8-M) instead of a standard BCH8?

Choose VIOX BCH8-M (available in 16M, 20M, 25M, 40M, and 63M in 2P/4P) whenever facility technicians need a front-panel 3-position selector (Off / Auto / On) to test lighting, HVAC, or heating circuits manually during commissioning or when a BMS/timer controller is offline.

熱 Why are 9 mm heat-dissipation spacers required when mounting modular contactors side-by-side?

When three or more continuously energized modular contactors are mounted flush next to each other inside a closed distribution board above 40 °C ambient, coil heat accumulates and accelerates insulation aging.

Inserting a 9 mm thermal spacer between every 2–3 contactors restores convective airflow and maintains rated AC-7a current.

Cross-Ref Are VIOX BMC7 and BCH8 modular contactors drop-in compatible with Schneider Acti9 iCT, ABB ESB, or Hager ESC?

Yes. BMC7 and BCH8 follow standard 18 mm-per-module DIN-rail geometry (18 mm for 1P/2P up to 25 A, 36 mm for 3P/4P 25 A and 2P 40–63 A, 54 mm for 4P 40–63 A/100 A) and IEC 61095 ratings for clean mechanical fit in standard distribution boards.

Always confirm control coil voltage and exact NO/NC contact code (/20, /11, /22, /31, /40) before substituting.

境界 When should I use an industrial AC contactor (CJX2s) instead of a modular contactor?

Modular contactors (IEC 61095) are engineered for quiet building distribution, lighting, heating, and light commercial loads up to 100 A (2NO/4NO at 100 A).

For frequent heavy industrial motor starting (AC-3 / AC-4 duty), high inrush currents, or loads above 100 A, upgrade to an IEC 60947-4-1 industrial AC contactor such as VIOX CJX2s.

OEM / Custom Does VIOX manufacture mixed NO/NC contact codes (/11, /02, /22, /31, /04) and custom coil voltages?

Yes. Beyond standard all-NO (/20, /40) stock, VIOX produces full BMC7 and BCH8 mixed and all-NC contact codes (/10, /01, /11, /02, /30, /03, /31, /22, /04 up to 63 A; 2NO/4NO at 100 A), clip-on 1NO+1NC and 2NO auxiliary contact blocks, and custom 12 V/24 V/48 V/110 V/230 V AC or silent AC/DC coils.

適切なモジュラー電磁接触器が必要ですか?
一緒に確認しましょう。.

Send your AC-7a/AC-7b load current, pole count, NO/NC contact code, coil voltage, and quantity. VIOX engineers will match the right BMC7, BCH8, or BCH8-M lineup.

Request Modular Contactor Quote