自動転送スイッチ (ATS)
Compare published VIOX automatic transfer switch series for source transfer in low-voltage distribution systems. Confirm poles, rated current, control mode and switching requirements by model.
Two-source transferNormal and alternate supply
ポール構成Confirm by series
制御ロジックAutomatic or manual functions
Project matchingVerify source and load data
What is an automatic transfer switch?
An automatic transfer switch monitors the selected supply conditions and transfers a load between a normal source and an alternate source according to its control logic. It is used where continuity of supply requires an arranged changeover path.
An ATS must be selected as part of the complete distribution system. Rated current, pole arrangement, utilization requirements, transfer sequence, control supply, source conditions and coordination with protective devices all need verification.
ATS Series Overview
製品データで既に入手可能な事実を使用して、公開されているVIOXモデルを比較してください。.
How to choose an ATS
Define both sources, the load and the required transfer sequence before comparing switch series.
Rated current and utilization
Match the connected load, switching duty and upstream protective-device coordination.
極および中性線の構成
Confirm the number of switched poles and the project neutral strategy.
Transfer and control logic
Check operating mode, source monitoring, delays and controller functions by model.
Mechanical integration
Verify mounting, wiring access, operating mechanism and enclosure space.
Define the transfer sequence
Transfer behavior varies by controller and switch series. Confirm the exact sequence before specifying the product.
Compare published ATS series
空欄は、現在の製品概要において値が利用できないことを示します。仕様を決定する前に、モデルページを開くか、データシートを請求してください。.
| シリーズ | 構成 | 定格電流 | 定格電圧 | Control mode |
|---|---|---|---|---|
| VIOX VOQ2-63 | — | — | — | — |
| VIOX VOQ3 | — | — | — | — |
| VIOX VOQ3-43 | — | — | — | — |
| VIOX VOQ3-46 | — | — | — | — |
| VIOX VOQ4-100E | — | — | — | — |
| VIOX VOQ4-100R | — | — | — | — |
| VIOX VOQ4-63AE | — | — | — | — |
| VIOX VOQ4-80AE | — | — | — | — |
ATS Applications
製品の正確な特性を確認する必要がある典型的な環境.
ATS Selection Questions
詳細な回路検証を行う前の、製品ファミリーの予備比較のためのクイックアンサー。.
What does an automatic transfer switch do?
An ATS transfers a load between two arranged supply sources according to the monitoring and control functions of the selected model.
Which information is needed to select an ATS?
Confirm both source voltages and frequencies, load current, poles, neutral arrangement, switching duty, transfer sequence, control requirements and installation method.
Is an ATS an overcurrent protective device?
An ATS performs switching and transfer. Overload and short-circuit protection must be coordinated with the protective devices specified for the system.
Can every ATS switch a generator supply?
Generator applications require compatible source monitoring, timing, control interfaces and switching ratings. Confirm these functions on the exact series.
What is the difference between automatic and manual transfer?
Automatic transfer uses monitoring and controller logic to initiate the sequence. Manual operation requires an operator action; available modes vary by model.
Need the Right ATS?
Let’s Define the Transfer Sequence.
Send both source details, load current, pole arrangement, control requirements, quantity and target market. VIOX will help identify the relevant published series.
Request ATS Support