VIOXエレクトリック
Language

Solar PV & Energy Storage Protection Components

Explore PV combiner boxes and the components used for string protection, surge protection and DC isolation. Then review their place in your solar system and the separate requirements of battery-side circuits.

Solar photovoltaic array with battery energy storage equipment
Solar PV and energy storage application

Inside a VIOX PV combiner box.

Explore string protection, surge protection and DC isolation in one interactive view. Select a component to see its role, or view a complete VIOX combiner box.

PV combiner componentsOpen-enclosure concept
VIOX DCヒューズホルダー VOR-32シリーズ

PV fuse protection

VIOX DCヒューズホルダー VOR-32シリーズ

Protect individual PV strings with a correctly specified gPV fuse and compatible holder. Confirm voltage, current and interruption ratings against the array design.

VIOX VSP1-C40PV/3(S) 1500V(D4) プラガブル多極SPD

DCサージ保護

VIOX VSP1-C40PV/3(S) 1500V(D4) プラガブル多極SPD

Limit transient overvoltage on the PV side. Confirm the operating voltage, protection modes and earthing arrangement for the installation.

VOPV DCアイソレータスイッチ ELR2シリーズ

DC isolation

VOPV DCアイソレータスイッチ ELR2シリーズ

Provide a defined manual isolation point. Confirm the DC voltage, current and pole arrangement for the chosen switch and system.

VOPV1000-3/1 太陽光発電接続箱

Complete combiner box

VOPV1000-3/1 太陽光発電接続箱

Bring string combining, protective components and enclosure requirements together. Review the complete assembly and its model-specific component list before ordering.

Component-family illustration, not a wiring diagram or the bill of materials for the box shown. Exact components and ratings vary by assembly.

See where the combiner fits in your PV system.

Follow the path from PV strings to the inverter. Confirm which combining, protection and isolation functions your system requires, then check the selected devices against its electrical ratings and installation requirements.

Conceptual system map—not a wiring diagram. The exact location, device type, ratings and coordination depend on the PV or storage architecture, equipment instructions and applicable installation requirements.

Battery-side DC protection is a separate design decision.

Confirm bidirectional current, maximum DC voltage, prospective fault current, isolation requirements and the battery or PCS manufacturer’s instructions before applying a PV-oriented component to a storage circuit.

Review system inputs

The same product category serves different system conditions.

Application scale alone does not determine a model. Array architecture, electrical ratings, environmental exposure and maintenance strategy define what must be verified.

住宅用屋上太陽光発電
Confirm string count, maximum array voltage, inverter instructions, accessibility and required isolation points.
Commercial & industrial rooftops
Review multiple arrays, longer conductor paths, combiner architecture, coordination and enclosure conditions.
Ground-mounted solar systems
Account for array segmentation, environmental exposure, cable routes, fault conditions and service isolation.
バッテリーエネルギー貯蔵
Verify source behavior, bidirectional current, DC fault energy and the exact battery and PCS requirements.

Prepare your solar DC protection specification.

Share confirmed values and mark unknown items for engineering review. A project name such as “rooftop solar” is not enough to select DC protective equipment.

システムアーキテクチャ
PV-only or PV plus storage, inverter or PCS arrangement, and required DC isolation points.
電圧
Maximum corrected PV voltage or battery operating-voltage range.
Current & strings
String current, parallel-string count, conductor capacity and expected operating current.
故障状態
Available DC fault current, source behavior and required interruption or backup coordination.
Surge & grounding
Earthing arrangement, protection modes, SPD location and upstream/downstream coordination.
Installation & order
Environment, enclosure, temperature, destination market, quantity and required documents.

Planning a solar PV or battery DC system?

Share the system voltage, current, string layout, protection scope, installation environment and target market with VIOX.

Build Your Solar Protection Request