VIOX ELECTRIC
言語

Fuse & Fuse Holder Manufacturer (124 Stocked SKUs · 27 Series · HRC, Solar PV 1500V, ESS 250kA & EV)

Factory-direct overcurrent protection across 8 engineering families—from NH/NT HRC & RT18 cylindrical fuses to VOPV 1500V DC solar, VOSA 250kA semiconductor/ESS, VOEV EV/EVSE, HR17 load-break disconnectors, BS88/J-Type utility, and 12–40.5 kV medium-voltage current-limiting fuses.

124 SKUs · 27 Series4 dedicated commercial fuse hubs
Up to 1500V–2000V DC250 kA high-speed & gPV solar clearing
IEC 60269 / DIN 43620Drop-in OEM dimensions + one-PO kitting
VIOX VOSA7-PK 1500V 4000A High-Speed Semiconductor and ESS Fuse
Complete Product Architecture · 8 Families · 124 Published SKUs

VIOX Fuse & Fuse Holder Family Comparison Matrix

Every voltage domain, mechanical footprint, IEC 60269 class, and dedicated specialty hub in one static engineering reference table.

Complete 8-family VIOX fuse and fuse holder catalog comparison
Fuse Family & Dedicated Hub Key Series & Mechanical Sizes Voltage & Current Class / Standard Representative Live Models
1. Solar PV DC Fuses & Holders → VOPV-20 / 30 / 30L / 30X / 40 / 63 (8×31.5 to 14×65mm) · VOPV-160 / 250 / 400 / 630 (NH0–3L) 1000V / 1100V / 1500V DC · 1A – 630A IEC 60269-6 · gPV VOPV-30L 1500V · VOPV-400D NH2XL · VOPV-630 3L
2. Semiconductor & ESS High-Speed → VOSA000–VOSA7-PK (DIN Blade & Flush-End) · VOGS4 / 7 · VOS92F–94FA · RGS2 500V – 2000V AC/DC · 10A – 4000A (250 kA) IEC 60269-4 · UL 248-13 · aR / gR VOSA00-CU ESS · VOSA4-PK 250kA · VOSA7-PK 4000A
3. EV Automotive, EVSE & UPS → VOEVu-50a への 400a · VOEVq-38b1 / 200a / 400f / 1200f 500V / 750V DC · 50A – 1200A ISO 8820 / EV High-Speed DC VOEVu-250a 500V · VOEVq-400f 750V · VOEVq-1200f
4. NH / NT HRC Blade Fuses → NH000 / NH00 / NH1 / NH2 / NH3 · NT00 / NT1 / NT2 / NT3 / NT4 + NT Extractor 690V AC · 4A – 1250A (120 kA HRC) IEC 60269-2 · DIN 43620 · gG / aM NH00 160A · NH3 630A · NT4 1250A
5. Cylindrical DIN-Rail Fuses & Holders → RT18-32 (10×38mm) · RT18-63 (14×51mm) · RT18L-125 (22×58mm) Links & Holders 500V AC · 1A – 125A IEC 60269-2 · gG / aM RT18-32 Holder · RT18-63 Holder · RT18L-125
6. HR17 Fuse Switch Disconnectors → HR17 Horizontal 3P (160A / 250A / 400A / 630A) · Bar Fuse Switch Disconnector 690V AC · 160A – 630A (Load-Break) IEC 60947-3 · AC-22B / 23B HR17 160A · HR17 400A · HR17 630A
7. BS88 / Africa J-Type / Australia HRC → VOG00 / VOG0K / VOG10C (BS88) · JPU / JSU / VOJPU31 (82/92mm) · VO-AUS-100B/C 240V – 690V AC · 2A – 630A BS 88 / AS / IEC 60269 Utility VOG10C BS88 · VOJPU31 630A · AU 100A HRC
8. Medium-Voltage Current-Limiting → XRNP (PT/VT) · XRNT (Transformer) · XRNC (Capacitor Bank) 12 kV – 40.5 kV AC · 15A – 240A IEC 60282-1 · MV HRC XRNP 12kV · XRNT 12kV · XRNC 40.5kV
Visual Product Browser · 37 Super-Series · 124 Consolidated Models

Browse All 37 VIOX Fuse Series by Family & Rating

Filter by application family or expand all 37 series below. Multi-ampere and multi-voltage ratings are consolidated into complete series pages with full specification tables.

Signature Fuse Tool 01 · Link + Holder / Disconnector Matcher

Match the Exact Fuse Link, Holder or Disconnector to Your Circuit

Select your circuit domain and current tier to pair the right VIOX fuse body, IEC utilization class (gG / aM / gPV / aR), and compatible holder or load-break disconnector.

Exact Part-Number Cross-Reference · Drop-In Replacement Guide

VIOX Fuse Cross-Reference vs. Bussmann, Mersen, Siemens & Littelfuse

Direct dimensional and IEC 60269 series cross-reference for panel builders, solar EPCs, and BESS integrators converting Tier-1 BOMs.

Exact part-number cross-reference between Bussmann, Mersen, Siemens, Littelfuse and VIOX fuses
Application / Footprint Eaton Bussmann Mersen / Ferraz Siemens / Littelfuse VIOX Direct Equivalent
10×38 / 14×51 / 22×58 DIN Holders CH10 / CH14 / CH22 US10 / US14 / US22 3NW7 / LPSC / LPHV VIOX RT18-32 / RT18-63 / RT18L-125
1000V / 1500V DC Solar PV String PV-xxA10F / PV-xxA10-85 HP10M / HP15M 3NW6 PV / SPF / SPXV VIOX VOPV-30 / VOPV-30X / VOPV-30L
1500V DC Solar Combiner NH XL PV-xxxA-1XL / 2XL / 3L HP15NH1XL / HP15NH2XL 3NE PV / SPXI NH VIOX VOPV-160 / 250 / 400D / 630
Square-Body High-Speed (690–2000V) 170M Series (DIN / Flush) Protistor® Size 000–7 3NE / 3NC / PSR VIOX VOSA000 – VOSA7-PK (250kA)
Round / BS88 Semiconductor High-Speed FWH / FWP / ET / FE A70QS / A70P / BS88 L70S / L70QS VIOX VOS92F–94FA / VOGS4–7 / RGS2
EV / EVSE / BESS 500V–750V DC EV / FWJ / 170M EV MEV / DC EV シリーズ EV500 / EV750 VIOX VOEVu (500V) / VOEVq (750V)
NH000–NT4 Industrial HRC Blade NH000–NH3 (DIN 43620) NH000–NH4 gG / aM 3NA3 / 3ND (NH HRC) VIOX NH000–NH3 / NT00–NT4
Horizontal 3P Fuse Switch Disconnector NH Switch Disconnector Multibloc® 160–630A 3NP1 ヒューズスイッチ VIOX HR17 160A / 250A / 400A / 630A
Engineering Verification & Honest Fit: Cross-references above are dimensional and IEC 60269 functional equivalents—always verify total clearing I²t, breaking capacity, and project UL/IEC certification before substitution. If a sole-source tender legally prohibits equivalents to Bussmann or Mersen, keep the specified part number; where IEC/DIN/BS88 specs govern and you need 35%–60% lower landed BOM cost and faster delivery, VIOX is built as your direct factory platform.
Signature Fuse Tool 02 · IEC 60269 Class & Load-Break Safety

Fuse Holder vs. Fuse Switch Disconnector — And 4 Field Failure Modes

Opening a non-load-break fuse holder under load causes severe arc flash. Follow these engineering rules to prevent holder melting, DC fires, and IGBT blowouts.

Load-Break Safety Architecture (IEC 60947-3 vs. IEC 60269) RT18 / VOPV DIN-Rail Holder • Isolation Carrier Only (No Arc Chute) • Sizes: 10×38, 14×51, 22×58, 10×85 ✗ NEVER OPEN UNDER LOAD Pair with upstream isolator / breaker HR17 3P Fuse Switch Disconnector • Integrated Arc Chutes (AC-22B/23B) • Ratings: 160A / 250A / 400A / 630A ✓ SAFE LOAD-BREAK SWITCHING 3P simultaneous NH00–NH3 disconnection IEC 60269 UTILIZATION CLASSES: gG Full-Range AC Cables · aM Motor Short-Circuit Backup gPV 1000–1500VDC Solar Strings · aR / gR Ultra-Rapid Semiconductor & ESS

Rule 1 · Never Substitute AC Fuses Into DC Solar or EV Circuits

DC faults have zero current-crossing. Always specify dedicated gPV (VOPV 1000–1500VDC) or DC-rated aR/EV (VOEV / VOSA) links.

Rule 2 · Use HR17 Disconnectors When Operators Switch Under Load

For 160A–630A main feeders and switchgear cabinets, HR17 horizontal 3P fuse switch disconnectors integrate arc-quenching chambers for safe AC-22B/23B load-break operation.

Rule 3 · Match Semiconductor I²t & Prospective Short-Circuit Current

Inverters, VFDs, and BESS racks require ultra-rapid VOSA square-body fuses (up to 250 kA) whose total clearing I²t stays strictly below the IGBT or battery contactor withstand limit.

FAILURE MODE 01

Holder Melts While Fuse Stays Intact

Weak clip pressure and unplated contacts generate localized I²R heating inside combiner boxes—melting the holder before the element reaches melt current.

VIOX Fix: High-tension copper-alloy clips, silver-plated blades, and UL94 V-0 housings across RT18 & VOPV.
FAILURE MODE 02

Sustained DC Arc Inside Combiner Boxes

Using 500VAC cylindrical fuses on 1000V–1500VDC PV strings or 750VDC EV batteries fails to quench DC arcs, causing ceramic fracture.

VIOX Fix: Dedicated VOPV (10×38 / 10×85 / 14×65 / NH2XL) and VOEV high-purity quartz-sand DC elements.
FAILURE MODE 03

IGBT & BESS Contactor Blowout

標準 gG fuses clear too slowly during high-energy battery or VFD short circuits, allowing let-through I²t to destroy semiconductors.

VIOX Fix: Ultra-rapid VOSA square-body fuses rated up to 250 kA そして 4000 A with low clearing I²t.
FAILURE MODE 04

Low-Density Sand Causing HRC Rupture

Under-filled fuses lack compacted high-purity silica sand and rupture violently under 100 kA+ prospective fault currents.

VIOX Fix: 100% cold-resistance checks, controlled-density 99%+ quartz sand filling, and steatite ceramic bodies.
Direct Factory Proof · 100% QC & OEM Customization

Inside VIOX Fuse Manufacturing, Quality Control & OEM Supply

Built for solar EPCs, ESS integrators, switchgear panel builders, and regional distributors who need verifiable IEC quality and complete one-PO kitting.

QC STAGE 01

100% Cold-Resistance Check

Every cylindrical, NH/NT, VOPV, and VOSA fuse link undergoes automated milliohm resistance verification to catch element weld defects before packing.

QC STAGE 02

Quartz Sand Density & Sealing

Controlled-vibration filling with 99%+ high-purity silica sand ensures consistent arc quenching across 1000V–1500VDC and 100kA–250kA faults.

QC STAGE 03

I²t & Temperature-Rise Audit

Batch-level time-current curve checks, power-loss verification, and holder clip spring-force testing prevent premature thermal aging.

QC STAGE 04

IEC 60269 / 60947-3 Traceability

Lot-coded ceramic bodies and factory test records retained per export PO across AC distribution, PV, ESS, EV, and MV lines.

OEM CAPABILITY 01

Ceramic Body & Holder Branding

Permanent pad-print or laser-etched brand logo, custom part numbers, and voltage/amp legends on ceramic tubes, NH bodies, and DIN holders.

OEM CAPABILITY 02

Striker, Microswitch & Tags

Specify DIN blade, flush-end bolted (PK/HK/GK), BS88 offset/center tags, or striker-pin indicators for remote SCADA alarms.

OEM CAPABILITY 03

Private-Label Box & Barcodes

Custom distributor inner boxes (10-pack / 3-pack), EAN/UPC barcodes, and multilingual safety inserts ready for regional retail.

OEM CAPABILITY 04

One-PO Switchgear Kitting

Consolidate fuse links, holders, HR17 disconnectors, MCB, MCCBそして SPD in one export shipment.

Factory Quotation Breakdown

Fuse & Fuse Holder Quotation Variables — What Moves Unit Pricing

見積変数 Standard Baseline Engineered / New-Energy Option Factory Quote Impact
1. Body & Element Design RT18 500VAC gG cylindrical ceramic fuse VOSA high-speed silver-element square-body (250kA) or 1500VDC gPV Pure silver element & heavy steatite ceramic drive unit cost.
2. Indication & Auxiliaries Standard non-indicating holder or blade link LED blown-fuse indicator (VOPV-30X), striker pin (VOPV-400D), or microswitch Adds modest remote-monitoring hardware delta.
3. Holder vs. Load-Break Switch DIN-rail non-load-break holder (RT18 / VOPV) HR17 3P Horizontal Fuse Switch Disconnector (160A–630A) Arc-chute chamber & heavy copper busbar contacts scale with amp frame.
4. OEM Printing & Batch Tier VIOX standard catalog printing & neutral carton Custom ceramic pad/laser logo, private-label inner box, mixed-amp kitting Fast engineering samples & flexible mixed-family export replenishment.
Engineering SamplesMulti-rating evaluation packs dispatched fast for thermal-rise & dimensional checks.
Flexible Mixed-Family MOQConsolidate Solar PV, ESS, EV, NH/NT & RT18 ratings in one shipment with OEM ceramic printing.
Full QC & Traceability100% milliohm cold-resistance testing, quartz-sand density control & lot-coded IEC records.
Signature Fuse Tool 03 · 5-Step Spec & RFQ Builder

Build Your Fuse & Holder RFQ Specification in 30 Seconds

Configure your family, voltage, assembly scope, and OEM branding below, then send directly into the VIOX engineering quote form.

Fuse & Fuse Holder Selection Questions

Engineering answers on load-break safety, IEC 60269 classes, DC vs. AC arc clearing, holder thermal derating, and OEM kitting.

Load-Break Can I open an RT18 cylindrical fuse holder or VOPV solar fuse holder under load?

No. Standard DIN-rail fuse holders (RT18-32, RT18-63, RT18L-125, VOPV-30/40/63) are non-load-break isolation carriers without arc chutes. Always de-energize the circuit upstream before opening.

When operators must switch feeders under load (160A–630A), specify an HR17 Horizontal 3P Fuse Switch Disconnector rated for IEC 60947-3 AC-22B / AC-23B duty.

IEC Classes What is the difference between IEC 60269 gG, aM, gPV, and aR fuse classes?

gG fuses provide full-range overload and short-circuit protection for general cables and distribution panels (RT18, NH/NT). aM fuses are partial-range motor-circuit fuses that withstand startup inrush and clear short circuits only.

gPV fuses (VOPV series) extinguish sustained 1000V–1500V DC solar arcs, while aR/gR ultra-rapid fuses (VOSA, VOGS, VOS) clear faults in milliseconds to protect IGBTs, VFDs, and ESS battery racks.

DC Safety Why can an AC 500V/690V fuse never be used on a 1000VDC or 1500VDC solar PV or EV battery circuit?

AC current crosses zero 100 or 120 times per second, assisting arc extinction. DC current has no zero-crossing; an AC fuse on a 1000V–1500VDC string or 750VDC EV battery pack can sustain an internal plasma arc, rupture the ceramic body, and ignite the enclosure.

Always specify dedicated DC-rated VOPV (gPV), VOEV, or DC-rated VOSA fuses.

Thermal Care Why do fuse holders sometimes melt even though the fuse link never blew?

Holder melting is almost always caused by high localized I²R contact resistance from loose terminal screws, undersized cables, weak clip spring force, or running a fuse continuously above 80% of rated current inside a hot combiner box without temperature derating.

相互参照 Are VIOX NH/NT, RT18, VOPV, and VOSA fuses dimensionally compatible with Bussmann, Mersen, and SIBA?

Yes. VIOX cylindrical (10×38, 14×51, 22×58, 10×85, 14×65 mm), NH/NT blade (DIN 43620 NH000–NT4), BS88 bolted tags (VOG), and square-body high-speed (VOSA000–VOSA7) fuses follow IEC 60269 and DIN mechanical footprints for drop-in replacement.

OEM / Kitting Can VIOX supply matched fuse links, holders, HR17 disconnectors, and OEM private-label packaging on one PO?

Yes. Distributors, solar EPCs, and panel builders can consolidate all 124 fuse SKUs together with matched DIN holders, NH bases, HR17 disconnectors, NT extractors, and upstream MCB/MCCB/SPD switchgear on a single export PO with custom ceramic printing and private-label cartons.

Need the Right Fuse Link, Holder or Disconnector?
Let’s Cross-Reference Your BOM.

Send your rated voltage (AC/DC), current rating, breaking capacity, physical size, or Tier-1 part number. VIOX engineers will match exact drop-in SKUs across all 124 fuse models.

Request Fuse BOM Quote