VIOX Electric
Language

Ceramic Terminal Block Manufacturer

Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.

Ceramic insulationVerify material and temperature data

Conductor matchingSize and terminal construction

Electrical dutyConfirm current and voltage

Mechanical formatPoles, pitch and mounting

VIOX Ceramic Terminal Block SERIESشائع شدہ پروڈکٹ رینج
Complete VIOX ceramic terminal block range on a dark background

What is a ceramic terminal block?

A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.

Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.

Define the environmentConfirm operating temperature, heat source, enclosure and contamination conditions.
Match the conductorVerify conductor size, terminal hardware and connection method.
Install and inspectUse the specified torque or connection procedure and maintain required clearances.

Complete VIOX Ceramic Terminal Block Range

All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.

Ceramic Construction Details

Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection

Secure conductor connection

Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body

Heat-resistant ceramic body

The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core

High-conductivity core

The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.

VIOX Ceramic Terminal Blocks Size Chart

Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.

CTB سیریز سائز چارٹ

Swipe to compare all columns

تفصیلاتماڈللمبائیچوڑائیاونچائیWiring range
1 میں 1 میں سے 10ACTB111019 ملی میٹر10 ملی میٹر15 ملی میٹر0.5–2.5mm²
1 میں 1 میں سے 30ACTB113018 ملی میٹر14 ملی میٹر18 ملی میٹر0.5–6mm²
2 میں 2 میں 10ACTB221020.7 ملی میٹر18.9 ملی میٹر13.9 ملی میٹر0.5–2.5mm²
2 میں 2 میں 15ACTB221528.4 ملی میٹر20.4 ملی میٹر16.3 ملی میٹر0.5–4mm²
2 میں 2 میں 30ACTB223031 ملی میٹر27 ملی میٹر18.9 ملی میٹر1.5–6mm²
2 میں 2 آؤٹ 60ACTB226038.7 ملی میٹر31 ملی میٹر22.7 ملی میٹر2.5–16mm²
2 ان 2 آؤٹ 100ACTB2210041.1 ملی میٹر30.2 ملی میٹر25.85 ملی میٹر6–25mm²
3 میں 3 میں سے 10ACTB331031 ملی میٹر20 ملی میٹر14.3 ملی میٹر0.5–2.5mm²
3 میں 3 میں سے 15ACTB331535.5 ملی میٹر20.3 ملی میٹر20.2 ملی میٹر0.5–4mm²
3 میں 3 میں سے 30ACTB333046.2 ملی میٹر26.4 ملی میٹر19.2 ملی میٹر1.5–6mm²
4 میں 4 آؤٹ 30ACTB443057 ملی میٹر25 ملی میٹر18.8 ملی میٹر1.5–6mm²
5 میں 5 میں سے 15ACTB551550 ملی میٹر22 ملی میٹر13 ملی میٹر0.5–2.5mm²
6 میں 6 میں سے 15ACTB661556.6 ملی میٹر21 ملی میٹر13 ملی میٹر0.5–2.5mm²
8 میں 8 میں سے 15ACTB881568 ملی میٹر21 ملی میٹر13 ملی میٹر0.5–2.5mm²
10 میں 10 میں سے 15ACTB10101588 ملی میٹر18 ملی میٹر15 ملی میٹر0.5–3.5mm²

ٹی بی سیریز سائز چارٹ

Swipe to compare all columns

ماڈلکنفیگریشنموجودہ درجہ بندیلمبائیچوڑائیاونچائیScrew typeMounting distance
ٹی بی 12124012 In 12 Out40A183 ملی میٹر24 ملی میٹر21 ملی میٹرM5165 ملی میٹر
ٹی بی 10104010 In 10 Out40A160 ملی میٹر24 ملی میٹر21 ملی میٹرM5144 ملی میٹر
ٹی بی 88408 In 8 Out40A141.5 ملی میٹر34.8 ملی میٹر24.6 ملی میٹرایم 395 ملی میٹر
ٹی بی 77607 In 7 Out60A135 ملی میٹر35 ملی میٹر19 ملی میٹرM5123 ملی میٹر
ٹی بی 66406 In 6 Out40A98 ملی میٹر24 ملی میٹر20 ملی میٹرایم 388 ملی میٹر
ٹی بی 44604 In 4 Out60A86 ملی میٹر33.5 ملی میٹر19.5 ملی میٹرM575 ملی میٹر
ٹی بی 44404 In 4 Out40A63 ملی میٹر23.8 ملی میٹر16.8 ملی میٹرایم 355.5 ملی میٹر
ٹی بی 33403 In 3 Out40A55.5 ملی میٹر25 ملی میٹر13.6 ملی میٹرایم 348 ملی میٹر
ٹی بی 22602 In 2 Out60A43.3 ملی میٹر30 ملی میٹر18.3 ملی میٹرM534 ملی میٹر

TBH 100A Series Size Chart

Swipe to compare all columns

ماڈلکنفیگریشنموجودہ درجہ بندیطول و عرض (L×W×H)Mounting distance
TBH221002 In 2 Out100A56 × 28 × 14mm40 ملی میٹر
TBH441004 In 4 Out100A86 × 28.5 × 14mm70mm
TBH661006 In 6 Out100A118.3 × 26.9 × 17mm106mm

How to choose a ceramic terminal block

Begin with temperature and circuit duty, then confirm conductor and mechanical details.

Temperature and material

Verify the published ceramic and terminal-material characteristics for the application.

Conductor range

Match conductor construction and cross-section to the exact terminal.

{"76":"برقی درجہ بندی"}

Confirm current, voltage, insulation and clearance requirements.

Poles, pitch and mounting

Check connection count, spacing, fasteners, cover and panel arrangement.

Treat heat and connection as one system

Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.

ایچHeat source and operating environment
ایElectrical rating and insulation requirement
ایمMounting, conductor and terminal hardware
Read the Ceramic Terminal Block selection guide

Compare published Ceramic Terminal Block series

Blank cells mean the value is not available in the current product summary. Open the model page or request its datasheet before specification.

سیریزکھمبےConductor rangeشرح شدہ کرنٹدرجہ حرارت
TB2260 سرامک ٹرمینل بلاک
TB3340 سیرامک ٹرمینل بلاک
TB4440 سرامک ٹرمینل بلاک
TB4460 سیرامک ٹرمینل بلاک
TB6640 سیرامک ٹرمینل بلاک
TB7760 سیرامک ٹرمینل بلاک
TB8840 سیرامک ٹرمینل بلاک
TB101040 سرامک ٹرمینل بلاک
TB121240 سیرامک ٹرمینل بلاک
CTB1110 سیرامک ٹرمینل بلاک
CTB1130 سیرامک ٹرمینل بلاک
CTB2210 سیرامک ٹرمینل بلاک
CTB2215 سیرامک ٹرمینل بلاک
CTB2230 سیرامک ٹرمینل بلاک
CTB2260 سیرامک ٹرمینل بلاک
CTB22100 سیرامک ٹرمینل بلاک
CTB3310 سیرامک ٹرمینل بلاک
CTB3315 سیرامک ٹرمینل بلاک
CTB3330 سیرامک ٹرمینل بلاک
CTB4430 سیرامک ٹرمینل بلاک
CTB5515 سیرامک ٹرمینل بلاک
CTB6615 سیرامک ٹرمینل بلاک
CTB8815 سیرامک ٹرمینل بلاک
CTB101015 سیرامک ٹرمینل بلاک
TBH22100 陶瓷端子板
ٹی بی ایچ 44100 سیرامک ٹرمینل بلاکس
TBH66100 陶瓷端子板

Ceramic Terminal Block Selection Questions

Quick answers for preliminary product-family comparison before detailed circuit verification.

Why use a ceramic terminal block?

Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.

How is current capacity verified?

Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.

Are all ceramic terminal blocks suitable for the same temperature?

No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.

Which conductor should be used?

Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.

Can ceramic terminals replace standard terminal blocks directly?

Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.

Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.

Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.

Request Ceramic Terminal Block Support