VIOX Electric
Language

Ceramic Terminal Block Manufacturer

Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.

Ceramic insulationVerify material and temperature data

Conductor matchingSize and terminal construction

Electrical dutyConfirm current and voltage

Механическое исполнениеPoles, pitch and mounting

VIOX Ceramic Terminal Block SERIESОпубликованный ассортимент продукции
Complete VIOX ceramic terminal block range on a dark background

What is a ceramic terminal block?

A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.

Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.

Define the environmentConfirm operating temperature, heat source, enclosure and contamination conditions.
Match the conductorVerify conductor size, terminal hardware and connection method.
Install and inspectUse the specified torque or connection procedure and maintain required clearances.

Complete VIOX Ceramic Terminal Block Range

All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.

Enclosed CTB Ceramic Terminal Blocks

Compact enclosed connectors covering 1-, 2-, 3-, 4-, 5-, 6-, 8- and 10-way arrangements.

Ceramic Construction Details

Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection

Secure conductor connection

Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body

Heat-resistant ceramic body

The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core

High-conductivity core

The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.

VIOX Ceramic Terminal Blocks Size Chart

Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.

Таблица размеров серии CTB

Swipe to compare all columns

СпецификацияМодельДлинаШиринаВысотаWiring range
1 вход 1 выход 10ACTB111019 мм10 мм15 мм0.5–2.5mm²
1 вход 1 выход 30ACTB113018 мм14 мм18 мм0.5–6mm²
2 входа 2 выхода 10ACTB221020,7 мм18,9 мм13,9 мм0.5–2.5mm²
2 входа 2 выхода 15ACTB221528,4 мм20,4 мм16,3 мм0.5–4mm²
2 входа 2 выхода 30ACTB223031 мм27 мм18,9 мм1.5–6mm²
2 входа 2 выхода 60ACTB226038,7 мм31 мм22,7 мм2.5–16mm²
2 входа 2 выхода 100ACTB2210041,1 мм30,2 мм25,85 мм6–25mm²
3 входа 3 выхода 10ACTB331031 мм20 мм14,3 мм0.5–2.5mm²
3 входа 3 выхода 15ACTB331535,5 мм20,3 мм20,2 мм0.5–4mm²
3 входа 3 выхода 30ACTB333046,2 мм26,4 мм19,2 мм1.5–6mm²
4 входа 4 выхода 30ACTB443057 мм25 мм18,8 мм1.5–6mm²
5 входов 5 выходов 15ACTB551550 мм22 мм13 мм0.5–2.5mm²
6 входов 6 выходов 15ACTB661556,6 мм21 мм13 мм0.5–2.5mm²
8 входов 8 выходов 15ACTB881568 мм21 мм13 мм0.5–2.5mm²
10 входов 10 выходов 15ACTB10101588 мм18 мм15 мм0.5–3.5mm²

Таблица размеров серии TB

Swipe to compare all columns

МодельКонфигурацияТекущий рейтингДлинаШиринаВысотаScrew typeMounting distance
TB12124012 In 12 Out40A183 мм24 мм21 ммM5165 мм
TB10104010 In 10 Out40A160 мм24 мм21 ммM5144 мм
TB88408 In 8 Out40A141,5 мм34,8 мм24,6 ммM395 мм
TB77607 In 7 Out60A135 мм35 мм19 ммM5123 мм
TB66406 In 6 Out40A98 мм24 мм20 ммM388 мм
TB44604 In 4 Out60A86 мм33,5 мм19,5 ммM575 мм
TB44404 In 4 Out40A63 мм23,8 мм16,8 ммM355,5 мм
TB33403 In 3 Out40A55,5 мм25 мм13,6 ммM348 мм
TB22602 In 2 Out60A43,3 мм30 мм18,3 ммM534 мм

TBH 100A Series Size Chart

Swipe to compare all columns

МодельКонфигурацияТекущий рейтингРазмеры (Д×Ш×В)Mounting distance
TBH221002 In 2 Out100A56 × 28 × 14mm40 мм
TBH441004 In 4 Out100A86 × 28.5 × 14mm70 мм
TBH661006 In 6 Out100A118.3 × 26.9 × 17mm106 мм

How to choose a ceramic terminal block

Begin with temperature and circuit duty, then confirm conductor and mechanical details.

Temperature and material

Verify the published ceramic and terminal-material characteristics for the application.

Conductor range

Match conductor construction and cross-section to the exact terminal.

Электрические характеристики

Confirm current, voltage, insulation and clearance requirements.

Poles, pitch and mounting

Check connection count, spacing, fasteners, cover and panel arrangement.

Treat heat and connection as one system

Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.

HHeat source and operating environment
EElectrical rating and insulation requirement
MMounting, conductor and terminal hardware
Read the Ceramic Terminal Block selection guide

Compare published Ceramic Terminal Block series

Пустые ячейки означают, что значение недоступно в текущем обзоре продукции. Откройте страницу модели или запросите технический паспорт перед составлением спецификации.

СерияПолюсаConductor rangeНоминальный токТемпература
TB2260 Керамическая клеммная колодка
TB3340 Керамическая клеммная колодка
TB4440 Керамическая клеммная колодка
TB4460 Керамическая клеммная колодка
TB6640 Керамическая клеммная колодка
TB7760 Керамическая клеммная колодка
TB8840 Керамическая клеммная колодка
TB101040 Керамическая клеммная колодка
TB121240 Керамическая клеммная колодка
Керамическая клеммная колодка CTB1110
Керамическая клеммная колодка CTB1130
Керамическая клеммная колодка CTB2210
Керамическая клеммная колодка CTB2215
Керамическая клеммная колодка CTB2230
Керамическая клеммная колодка CTB2260
Керамическая клеммная колодка CTB22100
Керамическая клеммная колодка CTB3310
Керамическая клеммная колодка CTB3315
Керамическая клеммная колодка CTB3330
Керамическая клеммная колодка CTB4430
Керамическая клеммная колодка CTB5515
Керамическая клеммная колодка CTB6615
Керамическая клеммная колодка CTB8815
CTB101015 Керамическая клеммная колодка
TBH22100 Ceramic Terminal Blocks
TBH44100 Керамические клеммные блоки
TBH66100 Керамические клеммные блоки

Ceramic Terminal Block Selection Questions

Быстрые ответы для предварительного сравнения семейств продуктов перед детальной проверкой цепи.

Why use a ceramic terminal block?

Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.

How is current capacity verified?

Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.

Are all ceramic terminal blocks suitable for the same temperature?

No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.

Which conductor should be used?

Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.

Can ceramic terminals replace standard terminal blocks directly?

Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.

Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.

Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.

Request Ceramic Terminal Block Support