Ceramic Terminal Block Manufacturer
Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.
Ceramic insulationVerify material and temperature data
Conductor matchingSize and terminal construction
Servicio eléctricoConfirm current and voltage
Formato mecánicoPoles, pitch and mounting

What is a ceramic terminal block?
A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.
Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.
Complete VIOX Ceramic Terminal Block Range
All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.
Standard TB Ceramic Terminal Blocks
Open terminal strips in 2- to 12-position configurations for heat-exposed equipment wiring.

TB2260 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB3340 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB4440 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB4460 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB6640 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB7760 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB8840 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB101040 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modelo
TB121240 Bloque de terminales cerámicos
Standard ceramic terminal blockRevisar datos del modeloEnclosed CTB Ceramic Terminal Blocks
Compact enclosed connectors covering 1-, 2-, 3-, 4-, 5-, 6-, 8- and 10-way arrangements.

CTB1110 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB1130 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB2210 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB2215 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB2230 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB2260 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB22100 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB3310 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB3315 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB3330 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB4430 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB5515 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB6615 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB8815 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modelo
CTB101015 Bloque de terminales cerámicos
Enclosed ceramic terminal blockRevisar datos del modeloTBH 100A Ceramic Terminal Blocks
High-current 2-, 4- and 6-position ceramic blocks with published 100A product data.
Ceramic Construction Details
Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection
Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body
The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core
The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.
VIOX Ceramic Terminal Blocks Size Chart
Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.
Tabla de tallas de la serie CTB
Swipe to compare all columns
| Especificación | Modelo | Longitud | Anchura | Altura | Wiring range |
|---|---|---|---|---|---|
| 1 entrada 1 salida 10A | CTB1110 | 19 mm | 10 mm | 15 mm | 0.5–2.5mm² |
| 1 entrada 1 salida 30A | CTB1130 | 18 mm | 14 mm | 18 mm | 0.5–6mm² |
| 2 Entradas 2 Salidas 10A | CTB2210 | 20,7 mm | 18,9 mm | 13,9 mm | 0.5–2.5mm² |
| 2 Entradas 2 Salidas 15A | CTB2215 | 28,4 mm | 20,4 mm | 16,3 mm | 0.5–4mm² |
| 2 Entradas 2 Salidas 30A | CTB2230 | 31 mm | 27 mm | 18,9 mm | 1.5–6mm² |
| 2 Entradas 2 Salidas 60A | CTB2260 | 38,7 mm | 31 mm | 22,7 mm | 2.5–16mm² |
| 2 Entradas 2 Salidas 100A | CTB22100 | 41,1 mm | 30,2 mm | 25,85 mm | 6–25mm² |
| 3 Entradas 3 Salidas 10A | CTB3310 | 31 mm | 20 mm | 14,3 mm | 0.5–2.5mm² |
| 3 Entradas 3 Salidas 15A | CTB3315 | 35,5 mm | 20,3 mm | 20,2 mm | 0.5–4mm² |
| 3 Entradas 3 Salidas 30A | CTB3330 | 46,2 mm | 26,4 mm | 19,2 mm | 1.5–6mm² |
| 4 Entradas 4 Salidas 30A | CTB4430 | 57 mm | 25 mm | 18,8 mm | 1.5–6mm² |
| 5 Entradas 5 Salidas 15A | CTB5515 | 50 mm | 22 mm | 13 mm | 0.5–2.5mm² |
| 6 Entradas 6 Salidas 15A | CTB6615 | 56,6 mm | 21 mm | 13 mm | 0.5–2.5mm² |
| 8 Entradas 8 Salidas 15A | CTB8815 | 68 mm | 21 mm | 13 mm | 0.5–2.5mm² |
| 10 Entradas 10 Salidas 15A | CTB101015 | 88 mm | 18 mm | 15 mm | 0.5–3.5mm² |
Tabla de tallas de la serie TB
Swipe to compare all columns
| Modelo | Configuración | Clasificación actual | Longitud | Anchura | Altura | Screw type | Mounting distance |
|---|---|---|---|---|---|---|---|
| TB121240 | 12 In 12 Out | 40A | 183 mm | 24 mm | 21 mm | M5 | 165 mm |
| TB101040 | 10 In 10 Out | 40A | 160 mm | 24 mm | 21 mm | M5 | 144 mm |
| TB8840 | 8 In 8 Out | 40A | 141,5 mm | 34,8 mm | 24,6 mm | M3 | 95 mm |
| TB7760 | 7 In 7 Out | 60A | 135 mm | 35 mm | 19 mm | M5 | 123 mm |
| TB6640 | 6 In 6 Out | 40A | 98 mm | 24 mm | 20 mm | M3 | 88 mm |
| TB4460 | 4 In 4 Out | 60A | 86 mm | 33,5 mm | 19,5 mm | M5 | 75 mm |
| TB4440 | 4 In 4 Out | 40A | 63 mm | 23,8 mm | 16,8 mm | M3 | 55,5 mm |
| TB3340 | 3 In 3 Out | 40A | 55,5 mm | 25 mm | 13,6 mm | M3 | 48 mm |
| TB2260 | 2 In 2 Out | 60A | 43,3 mm | 30 mm | 18,3 mm | M5 | 34 mm |
TBH 100A Series Size Chart
Swipe to compare all columns
| Modelo | Configuración | Clasificación actual | Dimensiones (L×An×Al) | Mounting distance |
|---|---|---|---|---|
| TBH22100 | 2 In 2 Out | 100A | 56 × 28 × 14mm | 40 mm |
| TBH44100 | 4 In 4 Out | 100A | 86 × 28.5 × 14mm | 70 mm |
| TBH66100 | 6 In 6 Out | 100A | 118.3 × 26.9 × 17mm | 106 mm |
How to choose a ceramic terminal block
Begin with temperature and circuit duty, then confirm conductor and mechanical details.
Temperature and material
Verify the published ceramic and terminal-material characteristics for the application.
Conductor range
Match conductor construction and cross-section to the exact terminal.
Clasificación eléctrica
Confirm current, voltage, insulation and clearance requirements.
Poles, pitch and mounting
Check connection count, spacing, fasteners, cover and panel arrangement.
Treat heat and connection as one system
Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.
Compare published Ceramic Terminal Block series
Las celdas en blanco significan que el valor no está disponible en el resumen actual del producto. Abra la página del modelo o solicite su hoja de datos antes de realizar la especificación.
Aplicaciones de bloques de terminales cerámicos
Entornos típicos donde deben verificarse las características exactas del producto.
Ceramic Terminal Block Knowledge & Selection Guides
Todos los artículos
Selección y dimensionamientoCómo elegir el borne cerámico adecuado
Ceramic Terminal Block Selection Questions
Respuestas rápidas para la comparación preliminar de familias de productos antes de la verificación detallada del circuito.
Why use a ceramic terminal block?
Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.
How is current capacity verified?
Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.
Are all ceramic terminal blocks suitable for the same temperature?
No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.
Which conductor should be used?
Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.
Can ceramic terminals replace standard terminal blocks directly?
Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.
Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.
Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.
Request Ceramic Terminal Block Support