Ceramic Terminal Block Manufacturer
Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.
Ceramic insulationVerify material and temperature data
Conductor matchingSize and terminal construction
Electrical dutyConfirm current and voltage
Mekanik formatPoles, pitch and mounting

What is a ceramic terminal block?
A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.
Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.
Complete VIOX Ceramic Terminal Block Range
All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.
Standard TB Ceramic Terminal Blocks
Open terminal strips in 2- to 12-position configurations for heat-exposed equipment wiring.

TB2260 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB3340 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB4440 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB4460 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB6640 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB7760 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB8840 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB101040 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyin
TB121240 Seramik Terminal Bloğu
Standard ceramic terminal blockModel verilerini inceleyinEnclosed CTB Ceramic Terminal Blocks
Compact enclosed connectors covering 1-, 2-, 3-, 4-, 5-, 6-, 8- and 10-way arrangements.

CTB1110 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB1130 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB2210 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB2215 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB2230 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB2260 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB22100 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB3310 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB3315 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB3330 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB4430 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB5515 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB6615 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB8815 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyin
CTB101015 Seramik Terminal Bloğu
Enclosed ceramic terminal blockModel verilerini inceleyinTBH 100A Ceramic Terminal Blocks
High-current 2-, 4- and 6-position ceramic blocks with published 100A product data.
Ceramic Construction Details
Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection
Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body
The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core
The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.
VIOX Ceramic Terminal Blocks Size Chart
Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.
CTB Serisi Beden Tablosu
Swipe to compare all columns
| Şartname | Model | Uzunluk | Genişlik | Yükseklik | Wiring range |
|---|---|---|---|---|---|
| 1 Giriş 1 Çıkış 10A | CTB1110 | 19mm | 10mm | 15mm | 0.5–2.5mm² |
| 1 Giriş 1 Çıkış 30A | CTB1130 | 18mm | 14mm | 18mm | 0.5–6mm² |
| 2 Giriş 2 Çıkış 10A | CTB2210 | 20,7 mm | 18.9mm | 13.9mm | 0.5–2.5mm² |
| 2 Giriş 2 Çıkış 15A | CTB2215 | 28,4 mm | 20,4 mm | 16,3 mm | 0.5–4mm² |
| 2 Giriş 2 Çıkış 30A | CTB2230 | 31mm | 27mm | 18.9mm | 1.5–6mm² |
| 2 Giriş 2 Çıkış 60A | CTB2260 | 38,7 mm | 31mm | 22,7 mm | 2.5–16mm² |
| 2 Giriş 2 Çıkış 100A | CTB22100 | 41.1mm | 30,2 mm | 25,85 mm | 6–25mm² |
| 3 Giriş 3 Çıkış 10A | CTB3310 | 31mm | 20mm | 14,3 mm | 0.5–2.5mm² |
| 3 Giriş 3 Çıkış 15A | CTB3315 | 35,5 mm | 20,3 mm | 20.2mm | 0.5–4mm² |
| 3 Giriş 3 Çıkış 30A | CTB3330 | 46,2 mm | 26,4 mm | 19,2 mm | 1.5–6mm² |
| 4 Giriş 4 Çıkış 30A | CTB4430 | 57mm | 25 mm | 18,8 mm | 1.5–6mm² |
| 5 Giriş 5 Çıkış 15A | CTB5515 | 50mm | 22mm | 13mm | 0.5–2.5mm² |
| 6 Giriş 6 Çıkış 15A | CTB6615 | 56,6 mm | 21mm | 13mm | 0.5–2.5mm² |
| 8 Giriş 8 Çıkış 15A | CTB8815 | 68mm | 21mm | 13mm | 0.5–2.5mm² |
| 10 Giriş 10 Çıkış 15A | CTB101015 | 88 mm | 18mm | 15mm | 0.5–3.5mm² |
TB Serisi Beden Tablosu
Swipe to compare all columns
| Model | Konfigürasyon | Mevcut derecelendirme | Uzunluk | Genişlik | Yükseklik | Screw type | Mounting distance |
|---|---|---|---|---|---|---|---|
| TB121240 | 12 In 12 Out | 40A | 183 mm | 24 mm | 21mm | M5 | 165 mm |
| TB101040 | 10 In 10 Out | 40A | 160 mm | 24 mm | 21mm | M5 | 144 mm |
| TB8840 | 8 In 8 Out | 40A | 141,5 mm | 34,8 mm | 24,6 mm | M3 | 95 mm |
| TB7760 | 7 In 7 Out | 60A | 135 mm | 35 mm | 19mm | M5 | 123mm |
| TB6640 | 6 In 6 Out | 40A | 98mm | 24 mm | 20mm | M3 | 88 mm |
| TB4460 | 4 In 4 Out | 60A | 86mm | 33,5 mm | 19,5 mm | M5 | 75 mm |
| TB4440 | 4 In 4 Out | 40A | 63mm | 23,8 mm | 16,8 mm | M3 | 55,5 mm |
| TB3340 | 3 In 3 Out | 40A | 55,5 mm | 25 mm | 13.6mm | M3 | 48mm |
| TB2260 | 2 In 2 Out | 60A | 43,3 mm | 30mm | 18,3 mm | M5 | 34mm |
TBH 100A Series Size Chart
Swipe to compare all columns
| Model | Konfigürasyon | Mevcut derecelendirme | Dimensions (L×W×H) | Mounting distance |
|---|---|---|---|---|
| TBH22100 | 2 In 2 Out | 100A | 56 × 28 × 14mm | 40mm |
| TBH44100 | 4 In 4 Out | 100A | 86 × 28.5 × 14mm | 70mm |
| TBH66100 | 6 In 6 Out | 100A | 118.3 × 26.9 × 17mm | 106mm |
How to choose a ceramic terminal block
Begin with temperature and circuit duty, then confirm conductor and mechanical details.
Temperature and material
Verify the published ceramic and terminal-material characteristics for the application.
Conductor range
Match conductor construction and cross-section to the exact terminal.
Elektriksel değerler
Confirm current, voltage, insulation and clearance requirements.
Poles, pitch and mounting
Check connection count, spacing, fasteners, cover and panel arrangement.
Treat heat and connection as one system
Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.
Compare published Ceramic Terminal Block series
Boş hücreler, değerin mevcut ürün özetinde bulunmadığı anlamına gelir. Şartname öncesinde model sayfasını açın veya veri sayfasını talep edin.
Seramik Klemens Uygulamaları
Ürün özelliklerinin kesin olarak doğrulanması gereken tipik ortamlar.
Ceramic Terminal Block Knowledge & Selection Guides
Tüm makaleler
Seçim ve BoyutlandırmaDoğru Seramik Terminal Bloğu Nasıl Seçilir
Ceramic Terminal Block Selection Questions
Detaylı devre doğrulamasından önce ön ürün ailesi karşılaştırması için hızlı yanıtlar.
Why use a ceramic terminal block?
Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.
How is current capacity verified?
Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.
Are all ceramic terminal blocks suitable for the same temperature?
No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.
Which conductor should be used?
Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.
Can ceramic terminals replace standard terminal blocks directly?
Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.
Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.
Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.
Request Ceramic Terminal Block Support