Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.

Ceramic insulationVerify material and temperature data

Conductor matchingSize and terminal construction

Electrical dutyConfirm current and voltage

Formato meccanicoPoles, pitch and mounting

VIOX Ceramic Terminal Block SERIESGamma di prodotti pubblicata
Complete VIOX ceramic terminal block range on a dark background

What is a ceramic terminal block?

A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.

Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.

Define the environmentConfirm operating temperature, heat source, enclosure and contamination conditions.
Match the conductorVerify conductor size, terminal hardware and connection method.
Install and inspectUse the specified torque or connection procedure and maintain required clearances.

Complete VIOX Ceramic Terminal Block Range

All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.

Ceramic Construction Details

Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection

Secure conductor connection

Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body

Heat-resistant ceramic body

The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core

High-conductivity core

The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.

VIOX Ceramic Terminal Blocks Size Chart

Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.

Tabella delle taglie della serie CTB

Swipe to compare all columns

SpecificaModelloLunghezzaLarghezzaAltezzaWiring range
1 ingresso 1 uscita 10ACTB111019 mm10 mm15 mm0.5–2.5mm²
1 ingresso 1 uscita 30ACTB113018 mm14 mm18 mm0.5–6mm²
2 ingressi 2 uscite 10ACTB221020,7 mm18,9 mm13,9 mm0.5–2.5mm²
2 ingressi 2 uscite 15ACTB221528,4 mm20,4 mm16,3 mm0.5–4mm²
2 ingressi 2 uscite 30ACTB223031 mm27 mm18,9 mm1.5–6mm²
2 ingressi 2 uscite 60ACTB226038,7 mm31 mm22,7 mm2.5–16mm²
2 ingressi 2 uscite 100ACTB2210041,1 mm30,2 mm25,85 mm6–25mm²
3 ingressi 3 uscite 10ACTB331031 mm20 mm14,3 mm0.5–2.5mm²
3 ingressi 3 uscite 15ACTB331535,5 mm20,3 mm20,2 mm0.5–4mm²
3 ingressi 3 uscite 30ACTB333046,2 mm26,4 mm19,2 mm1.5–6mm²
4 ingressi 4 uscite 30ACTB443057 mm25 mm18,8 mm1.5–6mm²
5 ingressi 5 uscite 15ACTB551550 mm22 mm13 mm0.5–2.5mm²
6 ingressi 6 uscite 15ACTB661556,6 mm21 mm13 mm0.5–2.5mm²
8 ingressi 8 uscite 15ACTB881568 mm21 mm13 mm0.5–2.5mm²
10 ingressi 10 uscite 15ACTB10101588 mm18 mm15 mm0.5–3.5mm²

Tabella delle taglie della serie TB

Swipe to compare all columns

ModelloConfigurazioneValutazione attualeLunghezzaLarghezzaAltezzaScrew typeMounting distance
TB12124012 In 12 Out40A183 mm24 mm21 mmM5165 mm
TB10104010 In 10 Out40A160 mm24 mm21 mmM5144 mm
TB88408 In 8 Out40A141,5 mm34,8 mm24,6 mmM395 mm
TB77607 In 7 Out60A135 mm35 mm19 mmM5123 mm
TB66406 In 6 Out40A98 mm24 mm20 mmM388 mm
TB44604 In 4 Out60A86 mm33,5 mm19,5 mmM575 mm
TB44404 In 4 Out40A63 mm23,8 mm16,8 mmM355,5 mm
TB33403 In 3 Out40A55,5 mm25 mm13,6 mmM348 mm
TB22602 In 2 Out60A43,3 mm30 mm18,3 mmM534 mm

TBH 100A Series Size Chart

Swipe to compare all columns

ModelloConfigurazioneValutazione attualeDimensioni (L mm W mm H)Mounting distance
TBH221002 In 2 Out100A56 × 28 × 14mm40 mm
TBH441004 In 4 Out100A86 × 28.5 × 14mm70mm
TBH661006 In 6 Out100A118.3 × 26.9 × 17mm106mm

How to choose a ceramic terminal block

Begin with temperature and circuit duty, then confirm conductor and mechanical details.

Temperature and material

Verify the published ceramic and terminal-material characteristics for the application.

Conductor range

Match conductor construction and cross-section to the exact terminal.

I valori nominali elettrici

Confirm current, voltage, insulation and clearance requirements.

Poles, pitch and mounting

Check connection count, spacing, fasteners, cover and panel arrangement.

Treat heat and connection as one system

Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.

HHeat source and operating environment
EElectrical rating and insulation requirement
MMounting, conductor and terminal hardware
Read the Ceramic Terminal Block selection guide

Compare published Ceramic Terminal Block series

Le celle vuote indicano che il valore non è disponibile nel riepilogo prodotto corrente. Aprire la pagina del modello o richiedere la relativa scheda tecnica prima della specifica.

Ceramic Terminal Block Selection Questions

Risposte rapide per un confronto preliminare tra famiglie di prodotti prima della verifica dettagliata del circuito.

Why use a ceramic terminal block?

Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.

How is current capacity verified?

Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.

Are all ceramic terminal blocks suitable for the same temperature?

No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.

Which conductor should be used?

Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.

Can ceramic terminals replace standard terminal blocks directly?

Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.

Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.

Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.

Request Ceramic Terminal Block Support