Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.

Ceramic insulationVerify material and temperature data

Conductor matchingSize and terminal construction

Electrical dutyConfirm current and voltage

รูปแบบทางกลPoles, pitch and mounting

VIOX Ceramic Terminal Block SERIESรายการผลิตภัณฑ์ที่เผยแพร่
Complete VIOX ceramic terminal block range on a dark background

What is a ceramic terminal block?

A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.

Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.

Define the environmentConfirm operating temperature, heat source, enclosure and contamination conditions.
Match the conductorVerify conductor size, terminal hardware and connection method.
Install and inspectUse the specified torque or connection procedure and maintain required clearances.

Complete VIOX Ceramic Terminal Block Range

All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.

Standard TB Ceramic Terminal Blocks

Open terminal strips in 2- to 12-position configurations for heat-exposed equipment wiring.

Enclosed CTB Ceramic Terminal Blocks

Compact enclosed connectors covering 1-, 2-, 3-, 4-, 5-, 6-, 8- and 10-way arrangements.

Ceramic Construction Details

Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection

Secure conductor connection

Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body

Heat-resistant ceramic body

The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core

High-conductivity core

The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.

VIOX Ceramic Terminal Blocks Size Chart

Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.

ตารางขนาดซีรีย์ CTB

Swipe to compare all columns

Specificationแบบอย่างความยาวความกว้างความสูงWiring range
1 เข้า 1 ออก 10ACTB111019มม.10มม.15มม.0.5–2.5mm²
1 เข้า 1 ออก 30ACTB113018มม.14มม.18มม.0.5–6mm²
2 เข้า 2 ออก 10ACTB221020.7มม.18.9มม.13.9มม.0.5–2.5mm²
2 เข้า 2 ออก 15ACTB221528.4มม.20.4มม.16.3มม.0.5–4mm²
2 เข้า 2 ออก 30ACTB223031มม.27มม.18.9มม.1.5–6mm²
2 เข้า 2 ออก 60ACTB226038.7มม.31มม.22.7มม.2.5–16mm²
2 เข้า 2 ออก 100ACTB2210041.1มม.30.2มม.25.85มม.6–25mm²
3 เข้า 3 ออก 10ACTB331031มม.20มม.14.3มม.0.5–2.5mm²
3 เข้า 3 ออก 15ACTB331535.5มม.20.3มม.20.2มม.0.5–4mm²
3 เข้า 3 ออก 30ACTB333046.2มม.26.4มม.19.2มม.1.5–6mm²
4 เข้า 4 ออก 30ACTB443057มม.25มม.18.8มม.1.5–6mm²
5 เข้า 5 ออก 15ACTB551550มม.22มม.13มม.0.5–2.5mm²
6 เข้า 6 ออก 15ACTB661556.6มม.21มม.13มม.0.5–2.5mm²
8 เข้า 8 ออก 15ACTB881568มม.21มม.13มม.0.5–2.5mm²
10 เข้า 10 ออก 15ACTB10101588มม.18มม.15มม.0.5–3.5mm²

ตารางขนาดซีรีย์ TB

Swipe to compare all columns

แบบอย่างการกำหนดค่าคะแนนปัจจุบันความยาวความกว้างความสูงScrew typeMounting distance
TB12124012 In 12 Out40เอ183มม.24มม.21มม.เอ็ม5165มม.
TB10104010 In 10 Out40เอ160มม.24มม.21มม.เอ็ม5144มม.
TB88408 In 8 Out40เอ141.5มม.34.8มม.24.6มม.เอ็ม395มม.
TB77607 In 7 Out60เอ135มม.35มม.19มม.เอ็ม5123มม.
TB66406 In 6 Out40เอ98มม.24มม.20มม.เอ็ม388มม.
TB44604 In 4 Out60เอ86มม.33.5มม.19.5มม.เอ็ม575มม.
TB44404 In 4 Out40เอ63มม.23.8มม.16.8มม.เอ็ม355.5มม.
TB33403 In 3 Out40เอ55.5มม.25มม.13.6มม.เอ็ม348มม.
TB22602 In 2 Out60เอ43.3มม.30มม.18.3มม.เอ็ม534มม.

TBH 100A Series Size Chart

Swipe to compare all columns

แบบอย่างการกำหนดค่าคะแนนปัจจุบันขนาด (ยาว×กว้าง×สูง)Mounting distance
TBH221002 In 2 Out100เอ56 × 28 × 14mm40มม.
TBH441004 In 4 Out100เอ86 × 28.5 × 14mm70 มม.
TBH661006 In 6 Out100เอ118.3 × 26.9 × 17mm106 มม.

How to choose a ceramic terminal block

Begin with temperature and circuit duty, then confirm conductor and mechanical details.

Temperature and material

Verify the published ceramic and terminal-material characteristics for the application.

Conductor range

Match conductor construction and cross-section to the exact terminal.

พิกัดทางไฟฟ้า

Confirm current, voltage, insulation and clearance requirements.

Poles, pitch and mounting

Check connection count, spacing, fasteners, cover and panel arrangement.

Treat heat and connection as one system

Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.

ชมHeat source and operating environment
อีElectrical rating and insulation requirement
MMounting, conductor and terminal hardware
Read the Ceramic Terminal Block selection guide

Compare published Ceramic Terminal Block series

ช่องว่างหมายถึงไม่มีค่าดังกล่าวในสรุปผลิตภัณฑ์ปัจจุบัน โปรดเปิดหน้าโมเดลหรือขอเอกสารข้อมูลทางเทคนิคก่อนทำการระบุสเปก.

ชุดวกเธอคงหัวเสีConductor rangeกระแสไฟฟ้าที่กำหนดอุณหภูมิ
TB2260 บล็อกเทอร์มินัลเซรามิก
TB3340 บล็อกเทอร์มินัลเซรามิก
TB4440 บล็อกเทอร์มินัลเซรามิก
TB4460 บล็อกเทอร์มินัลเซรามิก
TB6640 บล็อกเทอร์มินัลเซรามิก
TB7760 บล็อกเทอร์มินัลเซรามิก
TB8840 บล็อกเทอร์มินัลเซรามิก
TB101040 บล็อกเทอร์มินัลเซรามิก
TB121240 บล็อกเทอร์มินัลเซรามิก
CTB1110 บล็อกเทอร์มินัลเซรามิก
CTB1130 บล็อกเทอร์มินัลเซรามิก
CTB2210 บล็อกเทอร์มินัลเซรามิก
CTB2215 บล็อกเทอร์มินัลเซรามิก
CTB2230 บล็อกเทอร์มินัลเซรามิก
CTB2260 บล็อกเทอร์มินัลเซรามิก
CTB22100 บล็อกเทอร์มินัลเซรามิก
CTB3310 บล็อกเทอร์มินัลเซรามิก
CTB3315 บล็อกเทอร์มินัลเซรามิก
CTB3330 บล็อกเทอร์มินัลเซรามิก
CTB4430 บล็อกเทอร์มินัลเซรามิก
CTB5515 บล็อกเทอร์มินัลเซรามิก
CTB6615 บล็อกเทอร์มินัลเซรามิก
CTB8815 บล็อกเทอร์มินัลเซรามิก
CTB101015 บล็อกเทอร์มินัลเซรามิก
เทอร์มินอลบล็อกเซรามิก TBH22100
เทอร์มินอลบล็อกเซรามิก TBH44100
เทอร์มินอลบล็อกเซรามิก TBH66100

Ceramic Terminal Block Selection Questions

คำตอบเบื้องต้นสำหรับการเปรียบเทียบตระกูลผลิตภัณฑ์ก่อนการตรวจสอบวงจรโดยละเอียด.

Why use a ceramic terminal block?

Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.

How is current capacity verified?

Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.

Are all ceramic terminal blocks suitable for the same temperature?

No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.

Which conductor should be used?

Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.

Can ceramic terminals replace standard terminal blocks directly?

Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.

Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.

Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.

Request Ceramic Terminal Block Support