Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.

Ceramic insulationVerify material and temperature data

Conductor matchingSize and terminal construction

Electrical dutyConfirm current and voltage

Format mécaniquePoles, pitch and mounting

VIOX Ceramic Terminal Block SERIESGamme de produits publiée
Complete VIOX ceramic terminal block range on a dark background

What is a ceramic terminal block?

A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.

Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.

Define the environmentConfirm operating temperature, heat source, enclosure and contamination conditions.
Match the conductorVerify conductor size, terminal hardware and connection method.
Install and inspectUse the specified torque or connection procedure and maintain required clearances.

Complete VIOX Ceramic Terminal Block Range

All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.

Enclosed CTB Ceramic Terminal Blocks

Compact enclosed connectors covering 1-, 2-, 3-, 4-, 5-, 6-, 8- and 10-way arrangements.

Ceramic Construction Details

Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection

Secure conductor connection

Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body

Heat-resistant ceramic body

The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core

High-conductivity core

The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.

VIOX Ceramic Terminal Blocks Size Chart

Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.

Tableau des tailles de la série CTB

Swipe to compare all columns

SpécificationModèleLongueurLargeurHauteurWiring range
1 entrée 1 sortie 10ACTB111019 mm10 mm15 mm0.5–2.5mm²
1 entrée 1 sortie 30ACTB113018 mm14 mm18 mm0.5–6mm²
2 entrées 2 sorties 10ACTB221020,7 mm18,9 mm13,9 mm0.5–2.5mm²
2 entrées 2 sorties 15ACTB221528,4 mm20,4 mm16,3 mm0.5–4mm²
2 entrées 2 sorties 30ACTB223031mm27 mm18,9 mm1.5–6mm²
2 entrées 2 sorties 60ACTB226038,7 mm31mm22,7 mm2.5–16mm²
2 entrées 2 sorties 100ACTB2210041,1 mm30,2 mm25,85 mm6–25mm²
3 entrées 3 sorties 10ACTB331031mm20 mm14,3 mm0.5–2.5mm²
3 entrées 3 sorties 15ACTB331535,5 mm20,3 mm20,2 mm0.5–4mm²
3 entrées 3 sorties 30ACTB333046,2 mm26,4 mm19,2 mm1.5–6mm²
4 entrées 4 sorties 30ACTB443057mm25 mm18,8 mm1.5–6mm²
5 entrées 5 sorties 15ACTB551550 mm22 mm13 mm0.5–2.5mm²
6 entrées 6 sorties 15ACTB661556,6 mm21mm13 mm0.5–2.5mm²
8 entrées 8 sorties 15ACTB881568mm21mm13 mm0.5–2.5mm²
10 entrées 10 sorties 15ACTB10101588mm18 mm15 mm0.5–3.5mm²

Tableau des tailles de la série TB

Swipe to compare all columns

ModèleConfigurationNote actuelleLongueurLargeurHauteurScrew typeMounting distance
TB12124012 In 12 Out40A183mm24 mm21mmM5165mm
TB10104010 In 10 Out40A160 mm24 mm21mmM5144mm
TB88408 In 8 Out40A141,5 mm34,8 mm24,6 mmM395mm
TB77607 In 7 Out60A135 mm35 mm19 mmM5123mm
TB66406 In 6 Out40A98mm24 mm20 mmM388mm
TB44604 In 4 Out60A86mm33,5 mm19,5 mmM575 mm
TB44404 In 4 Out40A63mm23,8 mm16,8 mmM355,5 mm
TB33403 In 3 Out40A55,5 mm25 mm13,6 mmM348mm
TB22602 In 2 Out60A43,3 mm30 mm18,3 mmM534 mm

TBH 100A Series Size Chart

Swipe to compare all columns

ModèleConfigurationNote actuelleDimensions (L×l×H)Mounting distance
TBH221002 In 2 Out100A56 × 28 × 14mm40 mm
TBH441004 In 4 Out100A86 × 28.5 × 14mm70 mm
TBH661006 In 6 Out100A118.3 × 26.9 × 17mm106 mm

How to choose a ceramic terminal block

Begin with temperature and circuit duty, then confirm conductor and mechanical details.

Temperature and material

Verify the published ceramic and terminal-material characteristics for the application.

Conductor range

Match conductor construction and cross-section to the exact terminal.

Les caractéristiques électriques

Confirm current, voltage, insulation and clearance requirements.

Poles, pitch and mounting

Check connection count, spacing, fasteners, cover and panel arrangement.

Treat heat and connection as one system

Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.

HHeat source and operating environment
EElectrical rating and insulation requirement
MMounting, conductor and terminal hardware
Read the Ceramic Terminal Block selection guide

Compare published Ceramic Terminal Block series

Les cellules vides signifient que la valeur n'est pas disponible dans le résumé actuel du produit. Ouvrez la page du modèle ou demandez sa fiche technique avant toute spécification.

Ceramic Terminal Block Selection Questions

Réponses rapides pour une comparaison préliminaire des gammes de produits avant la vérification détaillée des circuits.

Why use a ceramic terminal block?

Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.

How is current capacity verified?

Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.

Are all ceramic terminal blocks suitable for the same temperature?

No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.

Which conductor should be used?

Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.

Can ceramic terminals replace standard terminal blocks directly?

Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.

Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.

Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.

Request Ceramic Terminal Block Support