VIOX Electric
Language

Low-Voltage Fuses & Fuse Holders

Compare VIOX fuse links, fuse holders and fuse disconnectors for low-voltage AC and DC circuit protection and isolation assemblies.

과전류 보호Fuse-link based protection

Product formLink, holder or disconnector

AC or DC system모델별 확인

차단 성능고장 전류 레벨 매칭

What is a low-voltage fuse?

A fuse uses a calibrated element that melts when current exceeds its time-current characteristics, interrupting the circuit. After operation, the fuse link must be replaced with the correct compatible rating and type.

The complete assembly may include a fuse link, holder, base or switch disconnector. Rated current, voltage, utilization category, breaking capacity, size and AC or DC suitability must be coordinated.

정상 전류The fuse element carries current within its approved operating characteristics.
Overcurrent energyExcess current heats the calibrated element according to its time-current curve.
회로 차단됨The element opens the circuit and the correct replacement link is required.

How to choose a fuse system

Select the fuse link and its holder or disconnector as one coordinated assembly.

정격 전류 및 전압

Match the circuit conditions and avoid using an AC-only rating for an unapproved DC application.

단 용량

Confirm the fuse can interrupt the prospective fault current at the specified voltage.

Fuse size and product form

Match the fuse-link dimensions, holder, mounting method and conductor arrangement.

활용도 카테고리

Choose the operating class and time-current behaviour required by the protected circuit.

One coordinated fuse assembly

A fuse link, holder and switch disconnector perform different roles. Verify compatibility before ordering.

01Fuse link interrupts the fault
02Fuse holder supports connection and replacement
03Fuse disconnector adds controlled isolation
Read the Fuse selection guide

Compare published Fuse series

빈 셀은 현재 제품 요약에서 해당 값을 사용할 수 없음을 의미합니다. 사양을 확인하기 전에 모델 페이지를 열거나 데이터시트를 요청하십시오.

시리즈Product form정격 전류정격 전압시스템
바 퓨즈 스위치 단로기160A–800AUp to 690V
원통형 퓨즈 링크퓨즈 링크
VIOX HR17Fuse Disconnector
VIOX NT0퓨즈 링크
VIOX NT00퓨즈 링크
VIOX NT00C퓨즈 링크
VIOX RT18-125퓨즈 홀더
VIOX RT18-63퓨즈 홀더

Fuse Selection Questions

상세 회로 검증 전 제품군 비교를 위한 빠른 답변.

What is the difference between a fuse link and a fuse holder?

The fuse link contains the calibrated element that interrupts overcurrent. The holder supports connection, installation and replacement of a compatible fuse link.

Can a fuse be reused after it operates?

No. An operated fuse link must be replaced with the correct compatible type and rating after the cause of the fault is resolved.

Can an AC fuse be used in a DC circuit?

Not unless the product is explicitly rated for the DC voltage and application. DC interruption can require different construction and ratings.

Which details are needed to select a fuse?

Confirm rated current, voltage, AC or DC system, utilization category, breaking capacity, physical size and the compatible holder or disconnector.

What does a fuse switch disconnector add?

It combines fuse-link based protection with a mechanism intended for controlled isolation. Exact switching and protection ratings must be checked on the product documentation.

Need the Right Fuse System?
Let’s Match the Assembly.

Send the circuit voltage, current, AC or DC system, required fuse form, quantity and target market. VIOX will help narrow the compatible product range.

Request Fuse Support