VIOX ELECTRIC
言語

VIOX 12kV 15A XRNP Current Limiting Fuse

XRNP VIOX XRNP type high voltage HRC current limiting fuses are designed with insert installation, which is convenient for installation and removal. The 12kV 15A XRNP Current Limiting Fuse is made of high-resistance metal wire and low-resistance metal wire. They are sealed in the.

VIOXシリーズ
XRNP
定格電圧
12kV
定格電流
15A
標準
IEC 60269

概要

XRNP VIOX XRNP type high voltage HRC current limiting fuses are designed with insert installation, which is convenient for installation and removal. The 12kV 15A XRNP Current Limiting Fuse is made of high-resistance metal wire and low-resistance metal wire. They are sealed in the fuse tube filled with chemically treated high-purity quartz sand. The fuse tube is made from heat resistance, high-duty ceramic or epoxy glass. When a fault circuit happens and causes an arc, quartz sand will extinguishes the arc immediately.

特徴

  • IEC60282-1
  • 高い破壊能力
  • Good performance and fast action in overload and short circuit protection
  • Comply with international standard size
  • 変圧器の保護
  • Switch Protection
  • Vacuum Contact Protection
  • XRNP Clips

仕様

XRNP Technical Specifications

Model/Size Rated Voltage (kV) 定格電流 (A) Rated Drop-Out Current (kA) 全体寸法
L (mm)
XRNP 3.6 0.5, 1, 2, 3.15 ,6.3 50 142
XRNP 7.2 0.5, 1, 2, 3.15 ,6.3 50 142/195
XRNP 12 0.5, 1, 2, 3.15 40 195
XRNP 24 0.5, 1, 2, 3.15 40 355
XRNP 40.5 0.5, 1, 2, 3.15 50 465

Selection & Installation Notes

  • Verify system maximum voltage (12kV) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

よくあるご質問

What voltage and current ratings does the VIOX 12kV 15A XRNP Current Limiting Fuse support?

This VIOX XRNP series is rated for 12kV with a current rating of 15A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX 12kV 15A XRNP Current Limiting Fuse?

The XRNP series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX 12kV 15A XRNP Current Limiting Fuse typically installed?

It is engineered for high-voltage current-limiting fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.