VIOX ELECTRIC
言語

HRC Industrial Fuse Manufacturer (NH000–NH3 · NT00–NT4 · BS88 · Africa J-Type · 12–40.5 kV MV)

High Rupturing Capacity (HRC) ceramic fuses engineered to clear up to 120 kA prospective short-circuit faults safely across industrial switchgear, motor feeders, utility feeder pillars, and medium-voltage transformers.

120 kA HRC690 V AC IEC 60269-2 gG / aM
NH000 – NT44 A to 1250 A DIN 43620 blades
BS88 / J / MVUtility & 12–40.5 kV XRNP/T/C
VIOX 690VAC 160A NH00 HRC Blade Fuse
VIOX HRC Industrial Fuses · 8 Series · 26 Live SKUs

Explore All VIOX HRC Industrial Fuses Series

Click any ampere or voltage rating pill below to open its full IEC technical specification table and dimensional datasheet.

Module 01 · Interactive HRC Industrial Fuses Selector

Match the Right NH, NT, BS88, J-Type or MV HRC Fuse to Your Feeder

Select your application tier and current range to match the exact VIOX series, mounting base, and safety verification rule.

Module 02 & 03 · Engineering Architecture & Field Reliability

Protection Physics & 4 Field Failure Modes in HRC Industrial Fuses

Technical architecture and field-proven failure prevention engineered directly into VIOX production.

IEC 60269-2 HRC Protection: gG Full-Range vs. aM Motor Backup gG / gL Full-Range HRC (NH / NT) • Clears both Overload + Short Circuit • Breaking: 120 kA @ 690 V AC ✓ Cables, Switchgear & Busbars Frames: NH000–NH3 / NT00–NT4 (4–1250A) aM Motor-Circuit Backup HRC • Rides Through 6–8× DOL Startup Inrush • Clears High-Energy Short Circuits Only ✓ Pair with Thermal Overload Relay Prevents nuisance tripping on heavy starts DIN 43620 / UTILITY HANDLING SAFETY: NH/NT Blades: Always use insulated NT Extractor or HR17 3P Load-Break Switch Utility Standards: BS88 Bolted (VOG) · Africa J-Type 82mm (JPU) / 92mm (JSU) · MV 12–40.5kV

Failure Mode 01 · Low-Density Sand Causing HRC Rupture

Under-filled ceramic tubes fail to absorb 100 kA+ arc energy and shatter inside switchboards. VIOX Fix: 99%+ compacted high-purity quartz sand & steatite ceramic bodies.

Failure Mode 02 · Nuisance Blowing on Motor Startups

Using gG links instead of aM on DOL motors causes repeated tripping during 6–8× startup inrush. VIOX Fix: Specify VIOX NH/NT aM partial-range motor backup links.

FAILURE MODE 01

Low-Density Sand Causing HRC Rupture

Under-filled ceramic tubes fail to absorb 100 kA+ arc energy and shatter inside switchboards.

VIOX Fix: 99%+ compacted high-purity quartz sand & steatite ceramic bodies.
FAILURE MODE 02

Nuisance Blowing on Motor Startups

Using gG links instead of aM on DOL motors causes repeated tripping during 6–8× startup inrush.

VIOX Fix: Specify VIOX NH/NT aM partial-range motor backup links.
FAILURE MODE 03

Live Arc Flash When Pulling Open NH Blades

Pulling NH00–NH3 links with pliers under load triggers severe phase-to-phase arc flash.

VIOX Fix: Use the insulated VIOX NT Fuse Extractor or HR17 3P load-break switch.
FAILURE MODE 04

Wrong Fixing Center on Utility J-Type Pillars

Ordering 82 mm JPU links for 92 mm JSU feeder pillars halts field commissioning.

VIOX Fix: Full stocked JPU (82 mm), JSU (92 mm) & VOJPU31 630A carriers.
Module 04 · Exact Part-Number Cross-Reference & Factory QC

HRC Fuse Cross-Reference: VIOX vs. Siemens 3NA3, Bussmann & Mersen

Direct mechanical and IEC standard cross-reference for panel builders, EPCs, and distributors converting Tier-1 BOMs.

Footprint / Rating Tier Eaton Bussmann Mersen / Ferraz Siemens / Littelfuse VIOX Direct Equivalent
DIN 43620 NH000–NH3 (100–630A) Bussmann NH000–NH3 gG/aM Mersen NH000–NH3 Siemens 3NA3 / 3ND VIOX NH000 / NH00 / NH1 / NH2 / NH3
High-Current NT00–NT4 (160–1250A) Bussmann NH4 / NT Mersen NH00–NH4 Siemens 3NA3 1250A VIOX NT00 / NT1 / NT2 / NT3 / NT4
British BS88 Bolted Tags Bussmann NITD / ESD / CD Mersen BS88 gG Lawson / GEC BS88 VIOX VOG00 / VOG0K / VOG10C
Africa J-Type Outdoor (82 / 92mm) Bussmann J-Type Wedge Mersen J-Type 415V Utility 82mm / 92mm VIOX JPU (82mm) / JSU (92mm) / VOJPU31
MV Transformer / PT / Capacitor Bussmann 12kV–36kV DIN Mersen Limitor® MV Siemens 3GD MV HRC VIOX XRNP / XRNT (12kV) / XRNC (40.5kV)
Engineering Confirmation: Verify total clearing I²t, breaking capacity, and project UL/IEC certification before substitution. Send your Tier-1 BOM via the RFQ builder below for rapid VIOX engineering verification.
100% Cold-Resistance QCAutomated milliohm verification & 99%+ compacted quartz sand density control per batch.
OEM Ceramic & Box BrandingPermanent laser/pad-printed logos, custom part legends & distributor inner cartons.
Consolidated One-PO KittingBundle HRC Industrial Fuses with matched holders, MCB, MCCB & SPD in one shipment.
Module 05 · 4-Step HRC Industrial Fuses RFQ Builder

Configure Your HRC Industrial Fuses Specification in 20 Seconds

Select your technical options below and prefill the VIOX engineering quote form with one click.

HRC Industrial Fuses Technical FAQ

Direct answers on standards, sizing, Tier-1 interchangeability, and factory OEM kitting.

gG vs aM What is the difference between NH/NT gG and aM HRC fuses?

gG HRC fuses provide full-range overload and short-circuit protection for general feeders and cables. aM HRC fuses are partial-range motor-circuit backup fuses designed to withstand high motor startup currents while clearing short circuits.

遮断 What breaking capacity do VIOX NH000–NH3 and NT00–NT4 HRC fuses achieve?

VIOX low-voltage NH and NT ceramic HRC fuses are rated up to 690 V AC with high rupturing capacity up to 120 kA per IEC 60269-2 and DIN 43620.

相互参照 Are VIOX NH fuses dimensionally interchangeable with Siemens 3NA3 and Bussmann NH?

Yes. All VIOX NH000, NH00, NH1, NH2, and NH3 blade dimensions and knife-contact spacing conform to DIN 43620 / IEC 60269-2 for drop-in replacement in standard NH bases and HR17 disconnectors.

MV HRC How do XRNP, XRNT, and XRNC medium-voltage fuses differ?

XRNP (12 kV, up to 15 A) protects voltage/potential transformers (PT/VT); XRNT (12 kV, up to 200 A) protects distribution power transformers; XRNC (40.5 kV, up to 240 A) is engineered for high-voltage capacitor bank protection.

Need HRC Industrial Fuses Datasheets or BOM Cross-Ref?
Talk Directly with VIOX Engineers.

Send your rated voltage, ampere steps, breaking capacity, or Tier-1 part numbers for rapid factory pricing and evaluation samples.

Request HRC Industrial Fuses Quote