Fuse & Fuse Holder Manufacturer (124 Stocked SKUs · 27 Series · HRC, Solar PV 1500V, ESS 250kA & EV)
Factory-direct overcurrent protection across 8 engineering families—from NH/NT HRC & RT18 cylindrical fuses to VOPV 1500V DC solar, VOSA 250kA semiconductor/ESS, VOEV EV/EVSE, HR17 load-break disconnectors, BS88/J-Type utility, and 12–40.5 kV medium-voltage current-limiting fuses.
VIOX Fuse & Fuse Holder Family Comparison Matrix
Every voltage domain, mechanical footprint, IEC 60269 class, and dedicated specialty hub in one static engineering reference table.
| Fuse Family & Dedicated Hub | Key Series & Mechanical Sizes | Voltage & Current | Class / Standard | Representative Live Models |
|---|---|---|---|---|
| 1. Solar PV DC Fuses & Holders → | VOPV-20 / 30 / 30L / 30X / 40 / 63 (8×31.5 to 14×65mm) · VOPV-160 / 250 / 400 / 630 (NH0–3L) |
1000V / 1100V / 1500V DC · 1A – 630A | IEC 60269-6 · gPV |
VOPV-30L 1500V · VOPV-400D NH2XL · VOPV-630 3L |
| 2. Semiconductor & ESS High-Speed → | VOSA000–VOSA7-PK (DIN Blade & Flush-End) · VOGS4 / 7 · VOS92F–94FA · RGS2 |
500V – 2000V AC/DC · 10A – 4000A (250 kA) | IEC 60269-4 · UL 248-13 · aR / gR |
VOSA00-CU ESS · VOSA4-PK 250kA · VOSA7-PK 4000A |
| 3. EV Automotive, EVSE & UPS → | VOEVu-50a إلى 400a · VOEVq-38b1 / 200a / 400f / 1200f |
500V / 750V DC · 50A – 1200A | ISO 8820 / EV High-Speed DC | VOEVu-250a 500V · VOEVq-400f 750V · VOEVq-1200f |
| 4. NH / NT HRC Blade Fuses → | NH000 / NH00 / NH1 / NH2 / NH3 · NT00 / NT1 / NT2 / NT3 / NT4 + NT Extractor |
690V AC · 4A – 1250A (120 kA HRC) | IEC 60269-2 · DIN 43620 · gG / aM |
NH00 160A · NH3 630A · NT4 1250A |
| 5. Cylindrical DIN-Rail Fuses & Holders → | RT18-32 (10×38mm) · RT18-63 (14×51mm) · RT18L-125 (22×58mm) Links & Holders |
500V AC · 1A – 125A | IEC 60269-2 · gG / aM |
RT18-32 Holder · RT18-63 Holder · RT18L-125 |
| 6. HR17 Fuse Switch Disconnectors → | HR17 Horizontal 3P (160A / 250A / 400A / 630A) · Bar Fuse Switch Disconnector |
690V AC · 160A – 630A (Load-Break) | IEC 60947-3 · AC-22B / 23B | HR17 160A · HR17 400A · HR17 630A |
| 7. BS88 / Africa J-Type / Australia HRC → | VOG00 / VOG0K / VOG10C (BS88) · JPU / JSU / VOJPU31 (82/92mm) · VO-AUS-100B/C |
240V – 690V AC · 2A – 630A | BS 88 / AS / IEC 60269 Utility | VOG10C BS88 · VOJPU31 630A · AU 100A HRC |
| 8. Medium-Voltage Current-Limiting → | XRNP (PT/VT) · XRNT (Transformer) · XRNC (Capacitor Bank) |
12 kV – 40.5 kV AC · 15A – 240A | IEC 60282-1 · MV HRC | XRNP 12kV · XRNT 12kV · XRNC 40.5kV |
Browse All 37 VIOX Fuse Series by Family & Rating
Filter by application family or expand all 37 series below. Multi-ampere and multi-voltage ratings are consolidated into complete series pages with full specification tables.
VOPV-20 1000VDC 20A 8×31.5mm Solar PV Fuse Link & Holder Series
Compact 8×31.5mm 1000V DC PV fuse link & DIN holder (1–20A)
- الجهد
- 1000 V DC
- الحالي
- 1–20 A
- قياسي
- IEC 60269-6 · gPV
VOPV-30 1000V / 1100V / 1500VDC 30A 10×38mm Solar PV Fuse Link Series
10×38mm gPV cylindrical solar string fuse links (1–30A, 1000–1500VDC)
- الجهد
- 1000–1500 V DC
- الحالي
- 1–30 A
- قياسي
- IEC 60269-6 · UL 248-19
VOPV-30 / VOPV-30X 1000V–1500VDC 30A 10×38mm DIN-Rail PV Fuse Holder (Standard, Heighten & LED)
10×38mm DIN-rail PV fuse holders with optional LED blown-fuse indicator
- الجهد
- 1000–1500 V DC
- الحالي
- 30 أمبير
- قياسي
- IEC 60269-6 · UL 4248-19
VOPV-30L 1000V / 1500VDC 30A 10×85mm Solar PV Fuse Link Series
Extended 10×85mm ceramic arc-tube gPV links for 1500V DC utility strings
- الجهد
- 1000 / 1500 V DC
- الحالي
- 2–30 A
- قياسي
- IEC 60269-6 · UL 248-19
VOPV-30L 1000V / 1500VDC 30A 10×85mm Solar PV DIN-Rail Fuse Holder Series
Matched 10×85mm DIN-rail fuse holder for 1000V & 1500V DC solar strings
- الجهد
- 1000 / 1500 V DC
- الحالي
- 30 أمبير
- قياسي
- IEC 60269-6 · gPV
VOPV-40 1000V / 1500VDC 40A 14×51mm Solar PV Fuse Link & DIN Holder Series
14×51mm thermal-protected sub-array PV fuse links & matched DIN holders
- الجهد
- 1000 / 1500 V DC
- الحالي
- 10–40 A
- قياسي
- IEC 60269-6 · gPV
VOPV-63 1000V / 1500VDC 63A 14×65mm Solar PV Fuse Link & DIN Holder Series
14×65mm high-amp string PV fuse links & matched DIN-rail holders
- الجهد
- 1000 / 1500 V DC
- الحالي
- 15–63 A
- قياسي
- IEC 60269-6 · gPV
VOPV-160 (NH0) & VOPV-250 (NH1XL) 1000V / 1500VDC Solar PV Fuse Link Series
Combiner-box NH0 (160A) & NH1XL (250A) blade gPV links for 1000–1500V DC
- الجهد
- 1000 / 1500 V DC
- الحالي
- 50–250 A
- قياسي
- IEC 60269-6 · gPV
VOPV-400D (NH2XL Striker) & VOPV-630 (3L Blade / Bolt) 1000V / 1500VDC PV Fuse Link Series
Main array NH2XL striker & 3L blade/bolt PV fuse links (200–630A)
- الجهد
- 1000 / 1500 V DC
- الحالي
- 200–630 A
- قياسي
- IEC 60269-6 · gPV
VOPV-160 / 250 / 400 / 630 (NH0, NH1XL, NH2XL & 3L) 1000V–1500VDC Solar PV Fuse Base Series
Heavy-duty 1000V & 1500V DC ceramic/SMC fuse bases for NH0 through 3L PV links
- الجهد
- 1000 / 1500 V DC
- الحالي
- 160–630 A
- قياسي
- IEC 60269-6 · gPV
VOSA000 / VOSA00 Square-Body High-Speed Semiconductor & ESS Fuse Series (500V–1000V)
Compact 500V–1000V DC/AC ESS battery rack & VFD square-body high-speed fuses
- الجهد
- 500–1000 V AC/DC
- الحالي
- 20–315 A
- قياسي
- IEC 60269-4 · aR/gR
VOSA01 / VOSA1 Square-Body High-Speed Semiconductor Fuse Series (690V–1500V · 50–700A)
DIN blade (GK/HK) & flush-end (PK) semiconductor fuses across 690V–1500V
- الجهد
- 690–1500 V AC/DC
- الحالي
- 50–700 A
- قياسي
- IEC 60269-4 · aR
VOSA2 Square-Body High-Speed Semiconductor Fuse Series (690V–1500V · 200–1000A)
High-current 690V–1500V inverter, rectifier & forced-air square-body fuses
- الجهد
- 690–1500 V AC/DC
- الحالي
- 200–1000 A
- قياسي
- IEC 60269-4 · aR
VOSA3-PK Heavy-Duty Square-Body High-Speed Fuse Series (690V–1500V · 400–2000A)
690V–1500V flush-end & heavy-duty PCS semiconductor protection fuses
- الجهد
- 690–1500 V AC/DC
- الحالي
- 400–2000 A
- قياسي
- IEC 60269-4 · aR
VOSA4 / VOSA5 Ultra-High-Power 250kA Semiconductor & BESS Fuse Series (1000V–2000V DC)
1000V–2000V DC ultra-rapid fuses up to 250 kA breaking for utility BESS & PCS
- الجهد
- 1000–2000 V DC
- الحالي
- 315–2000 A
- قياسي
- IEC 60269-4 · UL 248-13
VOSA7-PK 1500V 4000A 250kA High-Speed Semiconductor & BESS Fuse
Utility-scale BESS & rail traction 250 kA flush-end high-speed fuse
- الجهد
- 1500 V DC / 1250 V AC
- الحالي
- 1500–4000 A
- قياسي
- IEC 60269-4 · UL 248-13
VOS92F / VOS93F / VOS94FA 700V North American Round High-Speed Fuse Series (100–400A)
700V AC/DC round-body ultra-rapid semiconductor fuses (FWH/A70QS equivalent)
- الجهد
- 700 V AC/DC
- الحالي
- 100–400 A
- قياسي
- UL 248-13 · IEC 60269-4
VOGS4 / VOGS7 / RGS2 690V BS88 Style High-Speed Semiconductor Fuse Series (10–400A)
690V bolted BS88 ultra-rapid fuses for drives, rectifiers & UPS
- الجهد
- 690 V AC/DC
- الحالي
- 10–400 A
- قياسي
- BS 88-4 · IEC 60269-4
VOEVu 500VDC Automotive, EVSE & UPS High-Speed Fuse Series (50A–400A)
Full 8-rating bolt-down EV battery module, PDU & UPS DC fuse lineup (50–400A)
- الجهد
- 500 V DC
- الحالي
- 50–400 A
- قياسي
- ISO 8820 / EV DC
VOEVq 750VDC High-Current EV Traction & DC Fast Charger Fuse Series (50A–1200A)
Heavy-duty 750V DC traction battery & EVSE fast-charging fuses up to 1200A
- الجهد
- 750 V DC
- الحالي
- 50–1200 A
- قياسي
- EV / EVSE High-Breaking
690VAC 100A NH000 DIN 43620 HRC Blade Fuse
Compact NH000 690V AC 120kA ceramic HRC blade fuse (2–100A gG/aM)
- الجهد
- 690 فولت تيار متردد
- الحالي
- 2–100 A
- قياسي
- IEC 60269-2 · DIN 43620
690VAC 160A NH00 DIN 43620 HRC Blade Fuse
Standard NH00 690V AC 120kA industrial HRC blade fuse (4–160A gG/aM)
- الجهد
- 690 فولت تيار متردد
- الحالي
- 4–160 A
- قياسي
- IEC 60269-2 · DIN 43620
690VAC 250A NH1 DIN 43620 HRC Blade Fuse
NH1 690V AC 120kA feeder & motor HRC blade fuse (32–250A gG/aM)
- الجهد
- 690 فولت تيار متردد
- الحالي
- 32–250 A
- قياسي
- IEC 60269-2 · DIN 43620
690VAC 400A NH2 DIN 43620 HRC Blade Fuse
NH2 690V AC 120kA heavy distribution HRC blade fuse (63–400A gG/aM)
- الجهد
- 690 فولت تيار متردد
- الحالي
- 63–400 A
- قياسي
- IEC 60269-2 · DIN 43620
690VAC 630A NH3 DIN 43620 HRC Blade Fuse
NH3 690V AC 120kA main switchboard HRC blade fuse (250–630A gG/aM)
- الجهد
- 690 فولت تيار متردد
- الحالي
- 250–630 A
- قياسي
- IEC 60269-2 · DIN 43620
NT00 / NT1 / NT2 / NT3 / NT4 690VAC High-Current HRC Blade Fuse Series (160A–1250A)
Full 5-frame NT ceramic blade HRC fuses up to 1250A for main distribution
- الجهد
- 690 فولت تيار متردد
- الحالي
- 16–1250 A
- قياسي
- IEC 60269-2 · gG
Insulated NT / NH Fuse Extractor Handle
Heavy-duty insulated puller handle for safe NH000–NT4 fuse replacement
- الجهد
- Up to 690 V AC
- الحالي
- NH000–NT4
- قياسي
- IEC 60269 Accessory
RT18-32 500VAC 32A 10×38mm Cylindrical HRC Fuse Link & DIN-Rail Holder Series
Control panel & SPD backup 10×38mm ceramic fuse links + 35mm DIN holder
- الجهد
- 500 فولت تيار متردد
- الحالي
- 1–32 A
- قياسي
- IEC 60269-2 · gG/aM
RT18-63 500VAC 63A 14×51mm Cylindrical HRC Fuse Link & DIN-Rail Holder Series
Sub-feeder & motor control 14×51mm ceramic fuse links + DIN holder
- الجهد
- 500 فولت تيار متردد
- الحالي
- 2–63 A
- قياسي
- IEC 60269-2 · gG/aM
RT18L-125 500VAC 125A 22×58mm Cylindrical HRC Fuse Link & DIN-Rail Holder Series
High-amp 22×58mm cylindrical HRC fuse links + heavy-duty DIN holder
- الجهد
- 500 فولت تيار متردد
- الحالي
- 16–125 A
- قياسي
- IEC 60269-2 · gG/aM
HR17 690VAC Horizontal 3P Fuse Switch Disconnector Series (160A / 250A / 400A / 630A)
Full 4-frame IEC 60947-3 AC-22B/23B load-break NH fuse switch disconnector
- الجهد
- 690 فولت تيار متردد
- الحالي
- 160–630 A
- قياسي
- IEC 60947-3 · AC-23B
VOG00 / VOG0K / VOG10C BS88 Bolted & Offset Tag HRC Fuse Series (240V–550V)
Offset-bladed, offset-slotted & center-bolted BS88 industrial HRC fuses
- الجهد
- 240–550 V AC
- الحالي
- 2–400 A
- قياسي
- BS 88 / IEC 60269
JPU (82mm) / JSU (92mm) / VOJPU31 630A Africa J-Type Outdoor HRC Fuse & Carrier Series
415V AC wedge-type outdoor feeder pillar links (82/92mm) & 630A pole carrier
- الجهد
- 415 V AC
- الحالي
- 20–630 A
- قياسي
- BS 88 Part 5 · J-Type
VO-AUS-100B / VO-AUS-100C 690VAC 100A Australia Service & Cutout HRC Fuse Series
Black service & clear cutout 100A Australian utility HRC fuses
- الجهد
- 690 فولت تيار متردد
- الحالي
- 10–100 A
- قياسي
- AS / IEC 60269
12kV 15A XRNP Current-Limiting Voltage Transformer (PT) Fuse
12 kV indoor current-limiting HRC fuse for potential/voltage transformers
- الجهد
- 12 kV AC
- الحالي
- 0.5–15 A
- قياسي
- IEC 60282-1 · MV HRC
12kV 200A XRNT Transformer Protection Current-Limiting Fuse
12 kV RMU & distribution transformer current-limiting HRC fuse
- الجهد
- 12 kV AC
- الحالي
- 6.3–200 A
- قياسي
- IEC 60282-1 · MV HRC
40.5kV 240A XRNC Capacitor Protection High-Voltage Fuse
40.5 kV high-voltage current-limiting HRC fuse for capacitor banks
- الجهد
- 40.5 kV AC
- الحالي
- 10–240 A
- قياسي
- IEC 60282-1 · MV HRC
Match the Exact Fuse Link, Holder or Disconnector to Your Circuit
Select your circuit domain and current tier to pair the right VIOX fuse body, IEC utilization class (gG / aM / gPV / aR), and compatible holder or load-break disconnector.
VIOX Fuse Cross-Reference vs. Bussmann, Mersen, Siemens & Littelfuse
Direct dimensional and IEC 60269 series cross-reference for panel builders, solar EPCs, and BESS integrators converting Tier-1 BOMs.
| Application / Footprint | Eaton Bussmann | Mersen / Ferraz | Siemens / Littelfuse | VIOX Direct Equivalent |
|---|---|---|---|---|
| 10×38 / 14×51 / 22×58 DIN Holders | CH10 / CH14 / CH22 |
US10 / US14 / US22 |
3NW7 / LPSC / LPHV |
VIOX RT18-32 / RT18-63 / RT18L-125 |
| 1000V / 1500V DC Solar PV String | PV-xxA10F / PV-xxA10-85 |
HP10M / HP15M |
3NW6 PV / SPF / SPXV |
VIOX VOPV-30 / VOPV-30X / VOPV-30L |
| 1500V DC Solar Combiner NH XL | PV-xxxA-1XL / 2XL / 3L |
HP15NH1XL / HP15NH2XL |
3NE PV / SPXI NH |
VIOX VOPV-160 / 250 / 400D / 630 |
| Square-Body High-Speed (690–2000V) | 170M Series (DIN / Flush) |
Protistor® Size 000–7 |
3NE / 3NC / PSR |
VIOX VOSA000 – VOSA7-PK (250kA) |
| Round / BS88 Semiconductor High-Speed | FWH / FWP / ET / FE |
A70QS / A70P / BS88 |
L70S / L70QS |
VIOX VOS92F–94FA / VOGS4–7 / RGS2 |
| EV / EVSE / BESS 500V–750V DC | EV / FWJ / 170M EV |
MEV / DC EV السلسلة |
EV500 / EV750 |
VIOX VOEVu (500V) / VOEVq (750V) |
| NH000–NT4 Industrial HRC Blade | NH000–NH3 (DIN 43620) |
NH000–NH4 gG / aM |
3NA3 / 3ND (NH HRC) |
VIOX NH000–NH3 / NT00–NT4 |
| Horizontal 3P Fuse Switch Disconnector | NH Switch Disconnector |
Multibloc® 160–630A |
3NP1 مفتاح المصهر |
VIOX HR17 160A / 250A / 400A / 630A |
I²t, breaking capacity, and project UL/IEC certification before substitution. If a sole-source tender legally prohibits equivalents to Bussmann or Mersen, keep the specified part number; where IEC/DIN/BS88 specs govern and you need 35%–60% lower landed BOM cost and faster delivery, VIOX is built as your direct factory platform.
Fuse Holder vs. Fuse Switch Disconnector — And 4 Field Failure Modes
Opening a non-load-break fuse holder under load causes severe arc flash. Follow these engineering rules to prevent holder melting, DC fires, and IGBT blowouts.
Rule 1 · Never Substitute AC Fuses Into DC Solar or EV Circuits
DC faults have zero current-crossing. Always specify dedicated gPV (VOPV 1000–1500VDC) or DC-rated aR/EV (VOEV / VOSA) links.
Rule 2 · Use HR17 Disconnectors When Operators Switch Under Load
For 160A–630A main feeders and switchgear cabinets, HR17 horizontal 3P fuse switch disconnectors integrate arc-quenching chambers for safe AC-22B/23B load-break operation.
Rule 3 · Match Semiconductor I²t & Prospective Short-Circuit Current
Inverters, VFDs, and BESS racks require ultra-rapid VOSA square-body fuses (up to 250 kA) whose total clearing I²t stays strictly below the IGBT or battery contactor withstand limit.
Holder Melts While Fuse Stays Intact
Weak clip pressure and unplated contacts generate localized I²R heating inside combiner boxes—melting the holder before the element reaches melt current.
RT18 و VOPV.Sustained DC Arc Inside Combiner Boxes
Using 500VAC cylindrical fuses on 1000V–1500VDC PV strings or 750VDC EV batteries fails to quench DC arcs, causing ceramic fracture.
VOPV (10×38 / 10×85 / 14×65 / NH2XL) and VOEV high-purity quartz-sand DC elements.IGBT & BESS Contactor Blowout
قياسي gG fuses clear too slowly during high-energy battery or VFD short circuits, allowing let-through I²t to destroy semiconductors.
VOSA square-body fuses rated up to 250 kA و 4000 A with low clearing I²t.Low-Density Sand Causing HRC Rupture
Under-filled fuses lack compacted high-purity silica sand and rupture violently under 100 kA+ prospective fault currents.
Inside VIOX Fuse Manufacturing, Quality Control & OEM Supply
Built for solar EPCs, ESS integrators, switchgear panel builders, and regional distributors who need verifiable IEC quality and complete one-PO kitting.
100% Cold-Resistance Check
Every cylindrical, NH/NT, VOPV, and VOSA fuse link undergoes automated milliohm resistance verification to catch element weld defects before packing.
Quartz Sand Density & Sealing
Controlled-vibration filling with 99%+ high-purity silica sand ensures consistent arc quenching across 1000V–1500VDC and 100kA–250kA faults.
I²t & Temperature-Rise Audit
Batch-level time-current curve checks, power-loss verification, and holder clip spring-force testing prevent premature thermal aging.
IEC 60269 / 60947-3 Traceability
Lot-coded ceramic bodies and factory test records retained per export PO across AC distribution, PV, ESS, EV, and MV lines.
Ceramic Body & Holder Branding
Permanent pad-print or laser-etched brand logo, custom part numbers, and voltage/amp legends on ceramic tubes, NH bodies, and DIN holders.
Striker, Microswitch & Tags
Specify DIN blade, flush-end bolted (PK/HK/GK), BS88 offset/center tags, or striker-pin indicators for remote SCADA alarms.
Private-Label Box & Barcodes
Custom distributor inner boxes (10-pack / 3-pack), EAN/UPC barcodes, and multilingual safety inserts ready for regional retail.
One-PO Switchgear Kitting
Consolidate fuse links, holders, HR17 disconnectors, MCB, MCCBو SPD in one export shipment.
Fuse & Fuse Holder Quotation Variables — What Moves Unit Pricing
| متغير التسعير | Standard Baseline | Engineered / New-Energy Option | Factory Quote Impact |
|---|---|---|---|
| 1. Body & Element Design | RT18 500VAC gG cylindrical ceramic fuse |
VOSA high-speed silver-element square-body (250kA) or 1500VDC gPV |
Pure silver element & heavy steatite ceramic drive unit cost. |
| 2. Indication & Auxiliaries | Standard non-indicating holder or blade link | LED blown-fuse indicator (VOPV-30X), striker pin (VOPV-400D), or microswitch |
Adds modest remote-monitoring hardware delta. |
| 3. Holder vs. Load-Break Switch | DIN-rail non-load-break holder (RT18 / VOPV) |
HR17 3P Horizontal Fuse Switch Disconnector (160A–630A) |
Arc-chute chamber & heavy copper busbar contacts scale with amp frame. |
| 4. OEM Printing & Batch Tier | VIOX standard catalog printing & neutral carton | Custom ceramic pad/laser logo, private-label inner box, mixed-amp kitting | Fast engineering samples & flexible mixed-family export replenishment. |
Build Your Fuse & Holder RFQ Specification in 30 Seconds
Configure your family, voltage, assembly scope, and OEM branding below, then send directly into the VIOX engineering quote form.
Fuse engineering knowledge center
Technical deep-dives on HRC breaking capacity, DC arc extinction, load-break safety, and solar PV string sizing.
What Is an HRC Fuse? Working Principle, Ratings & Selection
اقرأ الدليل →AC Fuse vs. DC Fuse: Why 1000V–1500V DC Circuits Demand Dedicated Arc Quenching
اقرأ الدليل →Fuse Holder vs. Fuse Switch Disconnector: Load-Break Safety & IEC 60947-3
اقرأ الدليل →How to Properly Fuse a Solar Photovoltaic System (1000V / 1500V DC)
اقرأ الدليل →Fuse & Fuse Holder Selection Questions
Engineering answers on load-break safety, IEC 60269 classes, DC vs. AC arc clearing, holder thermal derating, and OEM kitting.
Load-Break Can I open an RT18 cylindrical fuse holder or VOPV solar fuse holder under load?
No. Standard DIN-rail fuse holders (RT18-32, RT18-63, RT18L-125, VOPV-30/40/63) are non-load-break isolation carriers without arc chutes. Always de-energize the circuit upstream before opening.
When operators must switch feeders under load (160A–630A), specify an HR17 Horizontal 3P Fuse Switch Disconnector rated for IEC 60947-3 AC-22B / AC-23B duty.
IEC Classes What is the difference between IEC 60269 gG, aM, gPV, and aR fuse classes?
gG fuses provide full-range overload and short-circuit protection for general cables and distribution panels (RT18, NH/NT). aM fuses are partial-range motor-circuit fuses that withstand startup inrush and clear short circuits only.
gPV fuses (VOPV series) extinguish sustained 1000V–1500V DC solar arcs, while aR/gR ultra-rapid fuses (VOSA, VOGS, VOS) clear faults in milliseconds to protect IGBTs, VFDs, and ESS battery racks.
DC Safety Why can an AC 500V/690V fuse never be used on a 1000VDC or 1500VDC solar PV or EV battery circuit?
AC current crosses zero 100 or 120 times per second, assisting arc extinction. DC current has no zero-crossing; an AC fuse on a 1000V–1500VDC string or 750VDC EV battery pack can sustain an internal plasma arc, rupture the ceramic body, and ignite the enclosure.
Always specify dedicated DC-rated VOPV (gPV), VOEV, or DC-rated VOSA fuses.
Thermal Care Why do fuse holders sometimes melt even though the fuse link never blew?
Holder melting is almost always caused by high localized I²R contact resistance from loose terminal screws, undersized cables, weak clip spring force, or running a fuse continuously above 80% of rated current inside a hot combiner box without temperature derating.
إحالة مرجعية Are VIOX NH/NT, RT18, VOPV, and VOSA fuses dimensionally compatible with Bussmann, Mersen, and SIBA?
Yes. VIOX cylindrical (10×38, 14×51, 22×58, 10×85, 14×65 mm), NH/NT blade (DIN 43620 NH000–NT4), BS88 bolted tags (VOG), and square-body high-speed (VOSA000–VOSA7) fuses follow IEC 60269 and DIN mechanical footprints for drop-in replacement.
OEM / Kitting Can VIOX supply matched fuse links, holders, HR17 disconnectors, and OEM private-label packaging on one PO?
Yes. Distributors, solar EPCs, and panel builders can consolidate all 124 fuse SKUs together with matched DIN holders, NH bases, HR17 disconnectors, NT extractors, and upstream MCB/MCCB/SPD switchgear on a single export PO with custom ceramic printing and private-label cartons.
Need the Right Fuse Link, Holder or Disconnector?
Let’s Cross-Reference Your BOM.
Send your rated voltage (AC/DC), current rating, breaking capacity, physical size, or Tier-1 part number. VIOX engineers will match exact drop-in SKUs across all 124 fuse models.
Request Fuse BOM Quote