Interruptores automáticos de caja moldeada (IEC 60947-2 · 10–2000 A)
Compare 18 dedicated VIOX MCCB and intelligent breaker platforms—from 10–2000 A thermomagnetic and electronic LCD distribution breakers to 1500 V DC solar PV isolators, 1140 V AC heavy feeders, IoT auto-reclosers, and motorized operators.
VIOX MCCB & Intelligent Breaker Series (18 Models)
Filter by trip architecture or browse all 18 factory-direct platforms covering 10 A through 2000 A—select any model to inspect full frame ratings and order codes.
VM6
VIOX VM6 Series Thermomagnetic MCCB
- Corriente Nominal
- 10–2000 A
- Tensión nominal
- AC 400 / 690 V
- Breaking (Icu)
- Hasta 100 kA
- Trip / Control
- Thermal-Magnetic (C/S/M/H)
VM6AL
VIOX VM6AL Overload Alarm Non-Trip MCCB
- Corriente Nominal
- 16–800 A
- Tensión nominal
- AC 400 / 690 V
- Breaking (Icu)
- Up to 85 kA
- Trip / Control
- Overload Alarm · Short-Circuit Trip
VM6RT
VIOX VM6RT Double-Adjustable Thermomagnetic MCCB
- Corriente Nominal
- 16–800 A
- Tensión nominal
- AC 400 / 690 V
- Breaking (Icu)
- Hasta 100 kA
- Trip / Control
- Adjustable Ir (0.7–1×In) & Im
VM6LY
VIOX VM6LY Thermomagnetic Earth-Leakage MCCB
- Corriente Nominal
- 16–800 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 65 kA
- Trip / Control
- Thermal-Magnetic + RCD (30–1000 mA)
VM6E
VIOX VM6E Electronic Trip MCCB
- Corriente Nominal
- 16–1600 A
- Tensión nominal
- AC 400 / 690 V
- Breaking (Icu)
- Hasta 100 kA
- Trip / Control
- Electronic LSI (Ir / Isd / Ii)
VM6EY
VIOX VM6EY Electronic LCD Display MCCB
- Corriente Nominal
- 16–1600 A
- Tensión nominal
- AC 400 / 690 V
- Breaking (Icu)
- Hasta 100 kA
- Trip / Control
- LCD LSIG + RS485 Modbus
VM6ELY
VIOX VM6ELY Electronic Leakage LCD MCCB
- Corriente Nominal
- 16–800 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 85 kA
- Trip / Control
- LCD Electronic + Adjustable RCD
VM7
VIOX VM7 High-Voltage AC MCCB (690–1140 V)
- Corriente Nominal
- 63–800 A
- Tensión nominal
- AC 690 / 800 / 1140 V
- Breaking (Icu)
- Up to 150 kA
- Trip / Control
- HV Arc Chute · Mining & Wind
VM7DC
VIOX VM7DC 1000 V / 1500 V DC Solar PV MCCB
- Corriente Nominal
- 16–1250 A
- Tensión nominal
- DC 1000 / 1500 V
- Breaking (Icu)
- Up to 50 kA DC
- Trip / Control
- DC Magnetic Arc-Quench · PV/BESS
VM6ZY-MP
VIOX VM6ZY-MP IoT Intelligent Circuit Breaker
- Corriente Nominal
- 63–800 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 65 kA
- Trip / Control
- IoT Telemetry + Motorized Reclose
VM6ZY-M
VIOX VM6ZY-M IoT Intelligent Breaker
- Corriente Nominal
- 63–800 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 65 kA
- Trip / Control
- RS485 / 4G / Bluetooth + Metering
VM6LE
VIOX VM6LE PV IoT Auto-Reclosing MCCB
- Corriente Nominal
- 63–630 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 50 kA
- Trip / Control
- Over/Under-Voltage + PV Reclose
VM7LE
VIOX VM7LE Intelligent Residual-Current MCCB
- Corriente Nominal
- 63–800 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 50 kA
- Trip / Control
- Smart RCD + Auto-Reclose Tracking
VM7E
VIOX VM7E Automatic Phase-Change Switch
- Corriente Nominal
- 63–125 A
- Tensión nominal
- AC 230 / 400 V
- Breaking (Icu)
- 3-Phase Load Balance
- Trip / Control
- Zero-Cross Phase Transfer
VM7E-ZB
VIOX VM7E-ZB Multifunctional Phase-Change Switch
- Corriente Nominal
- 63–125 A
- Tensión nominal
- AC 230 / 400 V
- Breaking (Icu)
- 3-Phase Load Balance
- Trip / Control
- Breaker + Phase-Change + RS485
DC6
VIOX DC6 Electric Operating Mechanism
- Corriente Nominal
- 125–1600 A Frames
- Tensión nominal
- AC/DC 24–400 V
- Breaking (Icu)
- VM6 / VM7 Compatible
- Trip / Control
- Remote Open / Close / Reset
VM6EY-MP3/JLY
VIOX VM6EY-MP3/JLY Four-Remote Intelligent MCCB
- Corriente Nominal
- 63–800 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 65 kA
- Trip / Control
- Telemetry · Signal · Control · Tune
ECB
VIOX ECB Intelligent Cost-Control MCCB
- Corriente Nominal
- 63–630 A
- Tensión nominal
- AC 400 V
- Breaking (Icu)
- Up to 50 kA
- Trip / Control
- Utility Prepaid Cutoff & Reclose
Compare all 18 VIOX MCCB & intelligent breaker series
Side-by-side matrix of published IEC 60947-2 rated currents, system voltages, ultimate breaking capacity (Icu), and trip/control architectures.
| Serie | Familia | Corriente nominal (In) | System Voltage (Ue) | Breaking Capacity (Icu) | Trip / Control Architecture | Ficha técnica |
|---|---|---|---|---|---|---|
| VM6 | Termomagnético | 10–2000 A | AC 400 / 690 V | Hasta 100 kA | Thermal-Magnetic (C/S/M/H) | View VM6 → |
| VM6AL | Termomagnético | 16–800 A | AC 400 / 690 V | Up to 85 kA | Overload Alarm · Short-Circuit Trip | View VM6AL → |
| VM6RT | Termomagnético | 16–800 A | AC 400 / 690 V | Hasta 100 kA | Adjustable Ir (0.7–1×In) & Im | View VM6RT → |
| VM6LY | Termomagnético | 16–800 A | AC 400 V | Up to 65 kA | Thermal-Magnetic + RCD (30–1000 mA) | View VM6LY → |
| VM6E | Electronic & LCD | 16–1600 A | AC 400 / 690 V | Hasta 100 kA | Electronic LSI (Ir / Isd / Ii) | View VM6E → |
| VM6EY | Electronic & LCD | 16–1600 A | AC 400 / 690 V | Hasta 100 kA | LCD LSIG + RS485 Modbus | View VM6EY → |
| VM6ELY | Electronic & LCD | 16–800 A | AC 400 V | Up to 85 kA | LCD Electronic + Adjustable RCD | View VM6ELY → |
| VM7 | High-Voltage & DC | 63–800 A | AC 690 / 800 / 1140 V | Up to 150 kA | HV Arc Chute · Mining & Wind | View VM7 → |
| VM7DC | High-Voltage & DC | 16–1250 A | DC 1000 / 1500 V | Up to 50 kA DC | DC Magnetic Arc-Quench · PV/BESS | View VM7DC → |
| VM6ZY-MP | IoT & Reclosing | 63–800 A | AC 400 V | Up to 65 kA | IoT Telemetry + Motorized Reclose | View VM6ZY-MP → |
| VM6ZY-M | IoT & Reclosing | 63–800 A | AC 400 V | Up to 65 kA | RS485 / 4G / Bluetooth + Metering | View VM6ZY-M → |
| VM6LE | IoT & Reclosing | 63–630 A | AC 400 V | Up to 50 kA | Over/Under-Voltage + PV Reclose | View VM6LE → |
| VM7LE | IoT & Reclosing | 63–800 A | AC 400 V | Up to 50 kA | Smart RCD + Auto-Reclose Tracking | View VM7LE → |
| VM7E | Control & Motorized | 63–125 A | AC 230 / 400 V | 3-Phase Load Balance | Zero-Cross Phase Transfer | View VM7E → |
| VM7E-ZB | Control & Motorized | 63–125 A | AC 230 / 400 V | 3-Phase Load Balance | Breaker + Phase-Change + RS485 | View VM7E-ZB → |
| DC6 | Control & Motorized | 125–1600 A Frames | AC/DC 24–400 V | VM6 / VM7 Compatible | Remote Open / Close / Reset | View DC6 → |
| VM6EY-MP3/JLY | Control & Motorized | 63–800 A | AC 400 V | Up to 65 kA | Telemetry · Signal · Control · Tune | View VM6EY-MP3/JLY → |
| ECB | Control & Motorized | 63–630 A | AC 400 V | Up to 50 kA | Utility Prepaid Cutoff & Reclose | View ECB → |
Why Switchboard MCCBs Fail in the Field — And How VIOX Engineers Around It
Distribution switchboard failures rarely stem from steady-state load current. They happen under high prospective fault energy, uncoordinated selectivity, DC arc plasma, and unmonitored phase imbalance.
Undersized Icu / Ics Breaking Capacity
Selecting an economical 25 kA frame downstream of a high-kVA transformer risks contact welding and arc-chamber rupture on bolted short circuits.
Upstream Nuisance Tripping
Fixed magnetic trip thresholds trip the main incomer simultaneously with a branch fault, blacking out healthy plant feeders.
AC Breakers Misapplied on Solar DC
Without a natural AC current zero-crossing, 1000–1500 V DC combiner faults sustain plasma arcs that destroy standard AC arc chutes.
Unmonitored Overload & Outages
Critical pumps, telecom sites, and distributed PV inverters suffer costly site dispatches when breakers trip without telemetry or auto-reclose.
IEC 60947-2 Trip Unit & Application Selection Guide
Match each distribution panel, motor feeder, renewable DC array, or smart-grid cabinet to the exact VIOX MCCB platform and trip unit architecture.
| Application / Feeder Type | Trip Unit Architecture | Target Electrical Envelope | Recommended VIOX Series | Key Engineering Check |
|---|---|---|---|---|
| General Commercial & Industrial Feeders | Thermal-Magnetic (TMF / TMD) | 10–2000 A · AC 400/690 V | VM6 / VM6RT | Verify C/S/M/H breaking tier vs transformer fault kA |
| Critical Fire Pumps & Continuous Process | Overload Alarm + Magnetic Trip | 16–800 A · AC 400/690 V | VM6AL Overload Alarm | Wire alarm contact to BMS; keeps circuit closed on overload |
| Selective Main Switchboards & Data Centers | Electronic LSI / LSIG + LCD | 16–1600 A · RS485 Modbus | VM6E / VM6EY | Set Ir, Isd, Ii curves per trip settings guide |
| Earth-Leakage & Personnel Protection | Thermomagnetic or LCD + RCD | 16–800 A · 30–1000 mA IΔn | VM6LY / VM6ELY | Coordinate residual delay time with downstream RCCBs |
| Wind, Mining & High-Voltage AC Distribution | High-Voltage AC Arc Chute | 63–800 A · AC 690–1140 V | VM7 High-Voltage AC | Confirm phase barrier clearances & Ui 1250 V insulation |
| Utility Solar PV Combiners & BESS Racks | DC Magnetic Arc-Blowout | 16–1250 A · DC 1000–1500 V | VM7DC 1500 V DC | Verify pole series wiring & ambient derating at 50–60 °C |
| Smart Grid, Distributed PV & Remote SCADA | IoT Metering + Motorized Reclose | 63–800 A · RS485 / 4G / BT | VM6ZY-M / VM6LE / VM6EY-MP3 | Pair with DC6 o VM7E for automated distribution |
How VIOX MCCBs Compare Across IEC 60947-2 Tiers
Objective engineering benchmark across current/voltage span, electronic LCD & leakage depth, smart IoT ecosystem, and factory-direct B2B supply.
| Evaluation Parameter | Global Tier-1 Industrial Lines | Entry-Tier Commodity Lines | VIOX VM6 / VM7 / IoT Line |
|---|---|---|---|
| El Cumplimiento De Los Estándares | IEC/EN 60947-2 | Basic 400 V AC only | IEC/EN 60947-2 (Full 10–2000 A) |
| High-Voltage & Solar DC Span | 690–1140 V AC / 1500 V DC | No true 1500 V DC / 1140 V AC | VM7 (1140 V AC) & VM7DC (1500 V DC) |
| Electronic LCD & Leakage Depth | Premium-priced modular trip units | Fixed thermomagnetic only | VM6E, VM6EY LCD, VM6LY & VM6ELY |
| Smart Grid & Automation | Complex external add-on gateways | No disponible | Integrated IoT, PV Reclose, Phase-Change & DC6 |
| OEM & Switchgear Supply | Fixed brand; long 800–2000 A lead times | Inconsistent silver-contact & Ics QA | Factory-direct pricing + OEM private label |
Direct Factory MCCB Lineup
VIOX manufactures all 18 IEC 60947-2 MCCB and intelligent breaker platforms (10–2000 A) directly from factory production—verified for thermal-magnetic trip calibration, high-kA short-circuit breaking endurance, electronic LSI accuracy, and OEM private-label laser marking for global switchgear builders and distributors.
MCCB Quotation Variables — What Moves Unit Pricing
Key technical and commercial drivers behind factory-direct MCCB quotes. See also 4 critical MCCB specification mistakes to avoid.
| Quotation Variable | Standard Spec Range | Pricing & Lead-Time Impact |
|---|---|---|
| Frame Size & Breaking Class | 125–2000 A · Class C / S / M / H (25–150 kA) | Drives silver-tungsten contact mass, arc chute plates, and copper terminal weight |
| Trip Unit & Voltage Rating | Thermomagnetic vs Electronic LCD vs 1500 V DC / 1140 V AC | Standard 3P/4P VM6 frames carry fastest factory stock dispatch |
| Internal Accessories & DC6 | OF / SD contacts, MX shunt, MN undervoltage, rotary handle, DC6 motor | Factory pre-installation saves panel-shop wiring labor and guarantees torque QA |
| OEM Branding & Consolidation | VIOX stock or private-label laser marking + custom cartons | Consolidate with Interruptores magnetotérmicos y diferenciales, Contactores de CAy RCBO in one shipment |
Sourcing Mixed-Frame Switchboard MCCBs or OEM Private-Label Stock?
Send your single-line current schedule, breaking capacity (Icu), pole counts, and accessory list—our factory team will return matched pricing and lead times.
MCCB engineering knowledge center
Technical guides written for switchgear designers, panel builders, and electrical procurement engineers.
Códigos de unidad de disparo de MCCB explicados: TMF, TMD, TMA, TMG y MA
Read guide →Thermal Magnetic vs Electronic Trip MCCB: Differences, Settings & Selection
Read guide →Comprensión de los ajustes de la unidad de disparo de un MCCB: Explicación de Ir, Im, Isd e Ii.
Read guide →4 Errores críticos en las especificaciones de los MCCB que ponen en riesgo el fallo del sistema
Read guide →Guía de accesorios para MCCB: Comprender los contactos OF, SD, SDE y SDV
Read guide →Por qué los MCCB no tienen curvas de disparo B, C o D (y qué utilizan en su lugar)
Read guide →MCCB Selection & Procurement Questions
Direct answers on thermomagnetic vs electronic LCD trip units, IEC 60947-2 Icu/Ics tiers, 1500 V DC solar breakers, IoT reclosing, and OEM factory supply.
Unidades de disparo When should I choose a thermomagnetic MCCB (VM6/VM6RT) versus an electronic LCD MCCB (VM6E/VM6EY)?
Specify VIOX VM6 or double-adjustable VM6RT thermomagnetic MCCBs for standard distribution feeders, motor branch circuits, and cost-sensitive panels where fixed or simple 0.7–1.0×In thermal adjustment meets coordination requirements.
Upgrade to VIOX VM6E or VM6EY electronic LCD MCCBs when you need precise LSI/LSIG time-current selectivity across upstream and downstream breakers, wider 0.4–1.0×In current tuning, neutral/ground-fault protection, or RS485 Modbus metering.
Poder de corte What is the difference between Icu, Ics, and breaking classes (C, S, M, H) under IEC 60947-2?
Under IEC 60947-2, Icu is the ultimate short-circuit breaking capacity a breaker can interrupt safely once, while Ics is the service breaking capacity it can interrupt and remain fully operational afterward—typically 75% to 100% of Icu on VIOX VM6 and VM7 frames.
VIOX breaking classes (C = Economical, S = Standard, M = Medium, H = High up to 100–150 kA) let panel builders match the breaker interrupt rating directly to transformer kVA and prospective fault current without over-specifying frame size.
Solar & HV Can a standard 400 V AC MCCB be used in a 1000 V or 1500 V DC solar PV combiner or BESS rack?
No. DC fault arcs have no natural zero-crossing, so applying an AC-rated MCCB on high-voltage DC circuits risks sustained arcing and enclosure rupture.
Always specify a dedicated DC breaker such as the VIOX VM7DC (1000 V / 1500 V DC, 16–1250 A) with magnetic arc-blowout chambers, or the VIOX VM7 (690–1140 V AC) for high-voltage wind, mining, and industrial AC feeders.
IoT & Reclosing Which VIOX MCCB series support remote SCADA control, automatic reclosing, and energy metering?
VIOX offers four dedicated smart-grid families: VM6ZY-MP and VM6ZY-M IoT circuit breakers (RS485/4G/Bluetooth telemetry with integrated motor reclosing), VM6LE PV IoT auto-reclosing breakers for distributed solar grid-tie points, and VM6EY-MP3/JLY four-remote SCADA breakers.
For residential or utility prepaid metering cabinets, VIOX also supplies ECB intelligent cost-control breakers and VM7E/VM7E-ZB automatic three-phase load-balancing phase-change switches.
Motorized / Aux What internal accessories and motorized operators fit VIOX VM6 and VM7 MCCB frames?
VIOX VM6 and VM7 frames accept modular shunt trips (MX), undervoltage releases (MN), auxiliary status contacts (OF), alarm trip contacts (SD), rotary through-door handles, plug-in/withdrawable bases, and mechanical interlocks.
For automated transfer switching or remote panel operation, pair 125 A–1600 A frames with the VIOX DC6 electric operating mechanism (AC/DC 24–400 V).
OEM / B2B Supply Can VIOX supply mixed-frame MCCB schedules with OEM private-label laser marking?
Yes. VIOX manufactures all 18 MCCB series directly for switchgear builders, EPC contractors, and electrical distributors—supporting mixed frame sizes (10–2000 A), custom breaking tiers, pre-installed internal accessories, and OEM private-label marking.
Send your panel single-line schedule, rated currents, voltages, and target breaking capacity for matched factory pricing and IEC 60947-2 test documentation.