VIOX ELECTRIC
Idioma

Interruptores automáticos de caja moldeada (IEC 60947-2 · 10–2000 A)

Compare 18 dedicated VIOX MCCB and intelligent breaker platforms—from 10–2000 A thermomagnetic and electronic LCD distribution breakers to 1500 V DC solar PV isolators, 1140 V AC heavy feeders, IoT auto-reclosers, and motorized operators.

10–2000 A FramesThermomagnetic, Electronic & LCD
Up to 1500 V DC / 1140 V ACIcu up to 150 kA · IEC 60947-2
18 Dedicated SeriesStandard, Leakage, IoT & Motorized
VIOX MCCB full product family lineup including VM6, VM7, electronic LCD, 1500V DC, and IoT intelligent circuit breakers

VIOX MCCB & Intelligent Breaker Series (18 Models)

Filter by trip architecture or browse all 18 factory-direct platforms covering 10 A through 2000 A—select any model to inspect full frame ratings and order codes.

VIOX VM6 Series Thermomagnetic MCCB
Core Thermomagnetic

VM6

VIOX VM6 Series Thermomagnetic MCCB

Corriente Nominal
10–2000 A
Tensión nominal
AC 400 / 690 V
Breaking (Icu)
Hasta 100 kA
Trip / Control
Thermal-Magnetic (C/S/M/H)
VIOX VM6AL Overload Alarm Non-Trip MCCB
Overload Alarm

VM6AL

VIOX VM6AL Overload Alarm Non-Trip MCCB

Corriente Nominal
16–800 A
Tensión nominal
AC 400 / 690 V
Breaking (Icu)
Up to 85 kA
Trip / Control
Overload Alarm · Short-Circuit Trip
VIOX VM6RT Double-Adjustable Thermomagnetic MCCB
Double Adjustable

VM6RT

VIOX VM6RT Double-Adjustable Thermomagnetic MCCB

Corriente Nominal
16–800 A
Tensión nominal
AC 400 / 690 V
Breaking (Icu)
Hasta 100 kA
Trip / Control
Adjustable Ir (0.7–1×In) & Im
VIOX VM6LY Thermomagnetic Earth-Leakage MCCB
Protección contra fugas

VM6LY

VIOX VM6LY Thermomagnetic Earth-Leakage MCCB

Corriente Nominal
16–800 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 65 kA
Trip / Control
Thermal-Magnetic + RCD (30–1000 mA)
VIOX VM6E Electronic Trip MCCB
Electronic LSI

VM6E

VIOX VM6E Electronic Trip MCCB

Corriente Nominal
16–1600 A
Tensión nominal
AC 400 / 690 V
Breaking (Icu)
Hasta 100 kA
Trip / Control
Electronic LSI (Ir / Isd / Ii)
VIOX VM6EY Electronic LCD Display MCCB
LCD Electronic

VM6EY

VIOX VM6EY Electronic LCD Display MCCB

Corriente Nominal
16–1600 A
Tensión nominal
AC 400 / 690 V
Breaking (Icu)
Hasta 100 kA
Trip / Control
LCD LSIG + RS485 Modbus
VIOX VM6ELY Electronic Leakage LCD MCCB
LCD + Leakage

VM6ELY

VIOX VM6ELY Electronic Leakage LCD MCCB

Corriente Nominal
16–800 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 85 kA
Trip / Control
LCD Electronic + Adjustable RCD
VIOX VM7 High-Voltage AC MCCB (690–1140 V)
High-Voltage AC

VM7

VIOX VM7 High-Voltage AC MCCB (690–1140 V)

Corriente Nominal
63–800 A
Tensión nominal
AC 690 / 800 / 1140 V
Breaking (Icu)
Up to 150 kA
Trip / Control
HV Arc Chute · Mining & Wind
VIOX VM7DC 1000 V / 1500 V DC Solar PV MCCB
1500 V DC Solar

VM7DC

VIOX VM7DC 1000 V / 1500 V DC Solar PV MCCB

Corriente Nominal
16–1250 A
Tensión nominal
DC 1000 / 1500 V
Breaking (Icu)
Up to 50 kA DC
Trip / Control
DC Magnetic Arc-Quench · PV/BESS
VIOX VM6ZY-MP IoT Intelligent Circuit Breaker
IoT Circuit Breaker

VM6ZY-MP

VIOX VM6ZY-MP IoT Intelligent Circuit Breaker

Corriente Nominal
63–800 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 65 kA
Trip / Control
IoT Telemetry + Motorized Reclose
VIOX VM6ZY-M IoT Intelligent Breaker
Smart Metering IoT

VM6ZY-M

VIOX VM6ZY-M IoT Intelligent Breaker

Corriente Nominal
63–800 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 65 kA
Trip / Control
RS485 / 4G / Bluetooth + Metering
VIOX VM6LE PV IoT Auto-Reclosing MCCB
PV Auto-Reclosing

VM6LE

VIOX VM6LE PV IoT Auto-Reclosing MCCB

Corriente Nominal
63–630 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 50 kA
Trip / Control
Over/Under-Voltage + PV Reclose
VIOX VM7LE Intelligent Residual-Current MCCB
Smart Residual Current

VM7LE

VIOX VM7LE Intelligent Residual-Current MCCB

Corriente Nominal
63–800 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 50 kA
Trip / Control
Smart RCD + Auto-Reclose Tracking
VIOX VM7E Automatic Phase-Change Switch
Phase-Change Switch

VM7E

VIOX VM7E Automatic Phase-Change Switch

Corriente Nominal
63–125 A
Tensión nominal
AC 230 / 400 V
Breaking (Icu)
3-Phase Load Balance
Trip / Control
Zero-Cross Phase Transfer
VIOX VM7E-ZB Multifunctional Phase-Change Switch
Multifunction Phase

VM7E-ZB

VIOX VM7E-ZB Multifunctional Phase-Change Switch

Corriente Nominal
63–125 A
Tensión nominal
AC 230 / 400 V
Breaking (Icu)
3-Phase Load Balance
Trip / Control
Breaker + Phase-Change + RS485
VIOX DC6 Electric Operating Mechanism
Motor Operator

DC6

VIOX DC6 Electric Operating Mechanism

Corriente Nominal
125–1600 A Frames
Tensión nominal
AC/DC 24–400 V
Breaking (Icu)
VM6 / VM7 Compatible
Trip / Control
Remote Open / Close / Reset
VIOX VM6EY-MP3/JLY Four-Remote Intelligent MCCB
Four-Remote SCADA

VM6EY-MP3/JLY

VIOX VM6EY-MP3/JLY Four-Remote Intelligent MCCB

Corriente Nominal
63–800 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 65 kA
Trip / Control
Telemetry · Signal · Control · Tune
VIOX ECB Intelligent Cost-Control MCCB
Prepaid Cost-Control

ECB

VIOX ECB Intelligent Cost-Control MCCB

Corriente Nominal
63–630 A
Tensión nominal
AC 400 V
Breaking (Icu)
Up to 50 kA
Trip / Control
Utility Prepaid Cutoff & Reclose

Compare all 18 VIOX MCCB & intelligent breaker series

Side-by-side matrix of published IEC 60947-2 rated currents, system voltages, ultimate breaking capacity (Icu), and trip/control architectures.

18-series VIOX MCCB comparison table
Serie Familia Corriente nominal (In) System Voltage (Ue) Breaking Capacity (Icu) Trip / Control Architecture Ficha técnica
VM6 Termomagnético 10–2000 A AC 400 / 690 V Hasta 100 kA Thermal-Magnetic (C/S/M/H) View VM6 →
VM6AL Termomagnético 16–800 A AC 400 / 690 V Up to 85 kA Overload Alarm · Short-Circuit Trip View VM6AL →
VM6RT Termomagnético 16–800 A AC 400 / 690 V Hasta 100 kA Adjustable Ir (0.7–1×In) & Im View VM6RT →
VM6LY Termomagnético 16–800 A AC 400 V Up to 65 kA Thermal-Magnetic + RCD (30–1000 mA) View VM6LY →
VM6E Electronic & LCD 16–1600 A AC 400 / 690 V Hasta 100 kA Electronic LSI (Ir / Isd / Ii) View VM6E →
VM6EY Electronic & LCD 16–1600 A AC 400 / 690 V Hasta 100 kA LCD LSIG + RS485 Modbus View VM6EY →
VM6ELY Electronic & LCD 16–800 A AC 400 V Up to 85 kA LCD Electronic + Adjustable RCD View VM6ELY →
VM7 High-Voltage & DC 63–800 A AC 690 / 800 / 1140 V Up to 150 kA HV Arc Chute · Mining & Wind View VM7 →
VM7DC High-Voltage & DC 16–1250 A DC 1000 / 1500 V Up to 50 kA DC DC Magnetic Arc-Quench · PV/BESS View VM7DC →
VM6ZY-MP IoT & Reclosing 63–800 A AC 400 V Up to 65 kA IoT Telemetry + Motorized Reclose View VM6ZY-MP →
VM6ZY-M IoT & Reclosing 63–800 A AC 400 V Up to 65 kA RS485 / 4G / Bluetooth + Metering View VM6ZY-M →
VM6LE IoT & Reclosing 63–630 A AC 400 V Up to 50 kA Over/Under-Voltage + PV Reclose View VM6LE →
VM7LE IoT & Reclosing 63–800 A AC 400 V Up to 50 kA Smart RCD + Auto-Reclose Tracking View VM7LE →
VM7E Control & Motorized 63–125 A AC 230 / 400 V 3-Phase Load Balance Zero-Cross Phase Transfer View VM7E →
VM7E-ZB Control & Motorized 63–125 A AC 230 / 400 V 3-Phase Load Balance Breaker + Phase-Change + RS485 View VM7E-ZB →
DC6 Control & Motorized 125–1600 A Frames AC/DC 24–400 V VM6 / VM7 Compatible Remote Open / Close / Reset View DC6 →
VM6EY-MP3/JLY Control & Motorized 63–800 A AC 400 V Up to 65 kA Telemetry · Signal · Control · Tune View VM6EY-MP3/JLY →
ECB Control & Motorized 63–630 A AC 400 V Up to 50 kA Utility Prepaid Cutoff & Reclose View ECB →

Why Switchboard MCCBs Fail in the Field — And How VIOX Engineers Around It

Distribution switchboard failures rarely stem from steady-state load current. They happen under high prospective fault energy, uncoordinated selectivity, DC arc plasma, and unmonitored phase imbalance.

01Fault Rupture

Undersized Icu / Ics Breaking Capacity

Selecting an economical 25 kA frame downstream of a high-kVA transformer risks contact welding and arc-chamber rupture on bolted short circuits.

VIOX EngineeringMatch C/S/M/H breaking tiers up to 100 kA (VM6) and 150 kA (VM7).
02Selectivity Loss

Upstream Nuisance Tripping

Fixed magnetic trip thresholds trip the main incomer simultaneously with a branch fault, blacking out healthy plant feeders.

VIOX EngineeringDeploy VM6E / VM6EY LSI short-time delay (Isd) for true discrimination.
03DC Arc Flash

AC Breakers Misapplied on Solar DC

Without a natural AC current zero-crossing, 1000–1500 V DC combiner faults sustain plasma arcs that destroy standard AC arc chutes.

VIOX EngineeringEspecificar VM7DC 1500 V DC with dedicated magnetic arc-blowout chambers.
04Blind Downtime

Unmonitored Overload & Outages

Critical pumps, telecom sites, and distributed PV inverters suffer costly site dispatches when breakers trip without telemetry or auto-reclose.

VIOX EngineeringUtilice VM6AL alarm-only, VM6ZY-M IoT, or VM6LE reclosers.

IEC 60947-2 Trip Unit & Application Selection Guide

Match each distribution panel, motor feeder, renewable DC array, or smart-grid cabinet to the exact VIOX MCCB platform and trip unit architecture.

IEC 60947-2 MCCB application and trip unit selection matrix
Application / Feeder Type Trip Unit Architecture Target Electrical Envelope Recommended VIOX Series Key Engineering Check
General Commercial & Industrial Feeders Thermal-Magnetic (TMF / TMD) 10–2000 A · AC 400/690 V VM6 / VM6RT Verify C/S/M/H breaking tier vs transformer fault kA
Critical Fire Pumps & Continuous Process Overload Alarm + Magnetic Trip 16–800 A · AC 400/690 V VM6AL Overload Alarm Wire alarm contact to BMS; keeps circuit closed on overload
Selective Main Switchboards & Data Centers Electronic LSI / LSIG + LCD 16–1600 A · RS485 Modbus VM6E / VM6EY Set Ir, Isd, Ii curves per trip settings guide
Earth-Leakage & Personnel Protection Thermomagnetic or LCD + RCD 16–800 A · 30–1000 mA IΔn VM6LY / VM6ELY Coordinate residual delay time with downstream RCCBs
Wind, Mining & High-Voltage AC Distribution High-Voltage AC Arc Chute 63–800 A · AC 690–1140 V VM7 High-Voltage AC Confirm phase barrier clearances & Ui 1250 V insulation
Utility Solar PV Combiners & BESS Racks DC Magnetic Arc-Blowout 16–1250 A · DC 1000–1500 V VM7DC 1500 V DC Verify pole series wiring & ambient derating at 50–60 °C
Smart Grid, Distributed PV & Remote SCADA IoT Metering + Motorized Reclose 63–800 A · RS485 / 4G / BT VM6ZY-M / VM6LE / VM6EY-MP3 Pair with DC6 o VM7E for automated distribution

How VIOX MCCBs Compare Across IEC 60947-2 Tiers

Objective engineering benchmark across current/voltage span, electronic LCD & leakage depth, smart IoT ecosystem, and factory-direct B2B supply.

VIOX MCCB benchmark against global Tier-1 and entry-tier lines
Evaluation Parameter Global Tier-1 Industrial Lines Entry-Tier Commodity Lines VIOX VM6 / VM7 / IoT Line
El Cumplimiento De Los Estándares IEC/EN 60947-2 Basic 400 V AC only IEC/EN 60947-2 (Full 10–2000 A)
High-Voltage & Solar DC Span 690–1140 V AC / 1500 V DC No true 1500 V DC / 1140 V AC VM7 (1140 V AC) & VM7DC (1500 V DC)
Electronic LCD & Leakage Depth Premium-priced modular trip units Fixed thermomagnetic only VM6E, VM6EY LCD, VM6LY & VM6ELY
Smart Grid & Automation Complex external add-on gateways No disponible Integrated IoT, PV Reclose, Phase-Change & DC6
OEM & Switchgear Supply Fixed brand; long 800–2000 A lead times Inconsistent silver-contact & Ics QA Factory-direct pricing + OEM private label

Direct Factory MCCB Lineup

VIOX manufactures all 18 IEC 60947-2 MCCB and intelligent breaker platforms (10–2000 A) directly from factory production—verified for thermal-magnetic trip calibration, high-kA short-circuit breaking endurance, electronic LSI accuracy, and OEM private-label laser marking for global switchgear builders and distributors.

MCCB Quotation Variables — What Moves Unit Pricing

Key technical and commercial drivers behind factory-direct MCCB quotes. See also 4 critical MCCB specification mistakes to avoid.

Quotation variables for VIOX MCCBs
Quotation Variable Standard Spec Range Pricing & Lead-Time Impact
Frame Size & Breaking Class 125–2000 A · Class C / S / M / H (25–150 kA) Drives silver-tungsten contact mass, arc chute plates, and copper terminal weight
Trip Unit & Voltage Rating Thermomagnetic vs Electronic LCD vs 1500 V DC / 1140 V AC Standard 3P/4P VM6 frames carry fastest factory stock dispatch
Internal Accessories & DC6 OF / SD contacts, MX shunt, MN undervoltage, rotary handle, DC6 motor Factory pre-installation saves panel-shop wiring labor and guarantees torque QA
OEM Branding & Consolidation VIOX stock or private-label laser marking + custom cartons Consolidate with Interruptores magnetotérmicos y diferenciales, Contactores de CAy RCBO in one shipment

Sourcing Mixed-Frame Switchboard MCCBs or OEM Private-Label Stock?

Send your single-line current schedule, breaking capacity (Icu), pole counts, and accessory list—our factory team will return matched pricing and lead times.

Request MCCB Quote →

MCCB engineering knowledge center

Technical guides written for switchgear designers, panel builders, and electrical procurement engineers.

2026 Technical Catalog · Online PDF

VIOX Full MCCB & Intelligent Breaker Selection Catalog

Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, accessory matrices, and factory order codes (PDF · 26.7 MB).

Open Full Catalog PDF ↗

MCCB Selection & Procurement Questions

Direct answers on thermomagnetic vs electronic LCD trip units, IEC 60947-2 Icu/Ics tiers, 1500 V DC solar breakers, IoT reclosing, and OEM factory supply.

Unidades de disparo When should I choose a thermomagnetic MCCB (VM6/VM6RT) versus an electronic LCD MCCB (VM6E/VM6EY)?

Specify VIOX VM6 or double-adjustable VM6RT thermomagnetic MCCBs for standard distribution feeders, motor branch circuits, and cost-sensitive panels where fixed or simple 0.7–1.0×In thermal adjustment meets coordination requirements.

Upgrade to VIOX VM6E or VM6EY electronic LCD MCCBs when you need precise LSI/LSIG time-current selectivity across upstream and downstream breakers, wider 0.4–1.0×In current tuning, neutral/ground-fault protection, or RS485 Modbus metering.

Poder de corte What is the difference between Icu, Ics, and breaking classes (C, S, M, H) under IEC 60947-2?

Under IEC 60947-2, Icu is the ultimate short-circuit breaking capacity a breaker can interrupt safely once, while Ics is the service breaking capacity it can interrupt and remain fully operational afterward—typically 75% to 100% of Icu on VIOX VM6 and VM7 frames.

VIOX breaking classes (C = Economical, S = Standard, M = Medium, H = High up to 100–150 kA) let panel builders match the breaker interrupt rating directly to transformer kVA and prospective fault current without over-specifying frame size.

Solar & HV Can a standard 400 V AC MCCB be used in a 1000 V or 1500 V DC solar PV combiner or BESS rack?

No. DC fault arcs have no natural zero-crossing, so applying an AC-rated MCCB on high-voltage DC circuits risks sustained arcing and enclosure rupture.

Always specify a dedicated DC breaker such as the VIOX VM7DC (1000 V / 1500 V DC, 16–1250 A) with magnetic arc-blowout chambers, or the VIOX VM7 (690–1140 V AC) for high-voltage wind, mining, and industrial AC feeders.

IoT & Reclosing Which VIOX MCCB series support remote SCADA control, automatic reclosing, and energy metering?

VIOX offers four dedicated smart-grid families: VM6ZY-MP and VM6ZY-M IoT circuit breakers (RS485/4G/Bluetooth telemetry with integrated motor reclosing), VM6LE PV IoT auto-reclosing breakers for distributed solar grid-tie points, and VM6EY-MP3/JLY four-remote SCADA breakers.

For residential or utility prepaid metering cabinets, VIOX also supplies ECB intelligent cost-control breakers and VM7E/VM7E-ZB automatic three-phase load-balancing phase-change switches.

Motorized / Aux What internal accessories and motorized operators fit VIOX VM6 and VM7 MCCB frames?

VIOX VM6 and VM7 frames accept modular shunt trips (MX), undervoltage releases (MN), auxiliary status contacts (OF), alarm trip contacts (SD), rotary through-door handles, plug-in/withdrawable bases, and mechanical interlocks.

For automated transfer switching or remote panel operation, pair 125 A–1600 A frames with the VIOX DC6 electric operating mechanism (AC/DC 24–400 V).

OEM / B2B Supply Can VIOX supply mixed-frame MCCB schedules with OEM private-label laser marking?

Yes. VIOX manufactures all 18 MCCB series directly for switchgear builders, EPC contractors, and electrical distributors—supporting mixed frame sizes (10–2000 A), custom breaking tiers, pre-installed internal accessories, and OEM private-label marking.

Send your panel single-line schedule, rated currents, voltages, and target breaking capacity for matched factory pricing and IEC 60947-2 test documentation.

¿Necesita el MCCB adecuado?
Confirmémoslo juntos.

Send your rated current, system voltage (AC or 1500 V DC), breaking capacity (Icu), pole configuration, and target market. VIOX engineers will match the right VM6, VM7, or IoT breaker series.

Request MCCB Quote