VIOX Electric
Language

Ceramic Terminal Block Manufacturer

Compare the complete VIOX ceramic terminal block range for elevated-temperature wiring, heaters, furnaces, lighting and industrial electrical assemblies.

Ceramic insulationVerify material and temperature data

Conductor matchingSize and terminal construction

Electrical dutyConfirm current and voltage

ទម្រង់មេកានិចPoles, pitch and mounting

VIOX Ceramic Terminal Block SERIESជួរផលិតផលដែលបានចេញផ្សាយ
Complete VIOX ceramic terminal block range on a dark background

What is a ceramic terminal block?

A ceramic terminal block uses a ceramic insulating body to support conductor connections in equipment where thermal conditions or material requirements differ from conventional plastic terminal products.

Selection must be based on the exact ceramic material, conductor range, terminal hardware, rated current and voltage, temperature conditions, pole count, pitch, mounting method and environmental exposure.

Define the environmentConfirm operating temperature, heat source, enclosure and contamination conditions.
Match the conductorVerify conductor size, terminal hardware and connection method.
Install and inspectUse the specified torque or connection procedure and maintain required clearances.

Complete VIOX Ceramic Terminal Block Range

All 27 published VIOX models are shown below, grouped by construction so buyers can compare the complete range without leaving the page.

Standard TB Ceramic Terminal Blocks

Open terminal strips in 2- to 12-position configurations for heat-exposed equipment wiring.

Enclosed CTB Ceramic Terminal Blocks

Compact enclosed connectors covering 1-, 2-, 3-, 4-, 5-, 6-, 8- and 10-way arrangements.

Ceramic Construction Details

Original VIOX product photography shows the connection hardware, ceramic body and internal conductor construction.

Secure conductor connection

Secure conductor connection

Round-ended terminal hardware supports a stable mechanical connection when installed to the product requirements.

Heat-resistant ceramic body

Heat-resistant ceramic body

The ceramic housing is intended for applications where published thermal and insulation characteristics must be verified.

High-conductivity core

High-conductivity core

The internal conductor and terminal hardware carry the circuit current; verify the exact model rating and conductor range.

VIOX Ceramic Terminal Blocks Size Chart

Dimensions and conductor ranges reproduced from the published VIOX model data. Open the corresponding product page before final specification.

តារាងទំហំស៊េរី CTB

Swipe to compare all columns

ការបញ្ជាក់គំរូប្រវែងទទឹងកម្ពស់Wiring range
1 ក្នុង 1 ចេញ 10ACTB111019 ម។10 ម។15 ម។0.5–2.5mm²
1 ក្នុង 1 ចេញ 30ACTB113018 ម។14 ម។18 ម។0.5–6mm²
2 ក្នុង 2 ចេញ 10ACTB221020.7 ម។18.9 ម។១៣.៩ ម។0.5–2.5mm²
2 ក្នុង 2 ចេញ 15ACTB221528.4 ម។20.4 ម។១៦.៣ ម។0.5–4mm²
2 ក្នុង 2 ចេញ 30ACTB2230៣១ ម។២៧ ម។18.9 ម។1.5–6mm²
2 ក្នុង 2 ចេញ 60ACTB2260៣៨.៧ ម។៣១ ម។២២.៧ ម។2.5–16mm²
2 ក្នុង 2 ចេញ 100ACTB2210041.1 ម។30.2 ម។២៥.៨៥ ម។6–25mm²
3 ក្នុង 3 ចេញ 10ACTB3310៣១ ម។20 ម។១៤.៣ ម។0.5–2.5mm²
3 ក្នុង 3 ចេញ 15ACTB3315៣៥.៥ ម។20.3 ម។20.2 ម។0.5–4mm²
3 ក្នុង 3 ចេញ 30ACTB333046.2 ម។26.4 ម។១៩.២ ម។1.5–6mm²
4 ក្នុង 4 ចេញ 30ACTB443057 ម។២៥ ម។18.8 ម។1.5–6mm²
5 ក្នុង 5 ចេញ 15ACTB551550 ម។22 ម។១៣ ម។0.5–2.5mm²
6 ក្នុង 6 ចេញ 15ACTB661556.6 ម។២១ ម។១៣ ម។0.5–2.5mm²
8 ក្នុង 8 ចេញ 15ACTB881568 ម។២១ ម។១៣ ម។0.5–2.5mm²
10 ក្នុង 10 ចេញ 15ACTB101015៨៨ ម។18 ម។15 ម។0.5–3.5mm²

តារាងទំហំស៊េរី TB

Swipe to compare all columns

គំរូការកំណត់រចនាសម្ព័ន្ធការវាយតម្លៃបច្ចុប្បន្នប្រវែងទទឹងកម្ពស់Screw typeMounting distance
TB12124012 In 12 Out40A183 ម។24 ម។២១ ម។ម៥165 ម។
TB10104010 In 10 Out40A160 ម។24 ម។២១ ម។ម៥១៤៤ ម។
TB88408 In 8 Out40A១៤១.៥ ម។៣៤.៨ ម។24.6 ម។ម៣៩៥ ម។
TB77607 In 7 Out60A១៣៥ ម។៣៥ ម។19 ម។ម៥១២៣ ម។
TB66406 In 6 Out40A៩៨ ម។24 ម។20 ម។ម៣៨៨ ម។
TB44604 In 4 Out60A៨៦ ម។33.5 ម។១៩.៥ ម។ម៥75 ម។
TB44404 In 4 Out40A៦៣ ម។២៣.៨ ម។១៦.៨ ម។ម៣55.5 ម។
TB33403 In 3 Out40A55.5 ម។២៥ ម។១៣.៦ ម។ម៣៤៨ ម។
TB22602 In 2 Out60A៤៣.៣ ម។30 ម។18.3 ម។ម៥៣៤ ម។

TBH 100A Series Size Chart

Swipe to compare all columns

គំរូការកំណត់រចនាសម្ព័ន្ធការវាយតម្លៃបច្ចុប្បន្នវិមាត្រ (L×W×H)Mounting distance
TBH221002 In 2 Out100A56 × 28 × 14mm40 ម។
TBH441004 In 4 Out100A86 × 28.5 × 14mm70mm
TBH661006 In 6 Out100A118.3 × 26.9 × 17mm106mm

How to choose a ceramic terminal block

Begin with temperature and circuit duty, then confirm conductor and mechanical details.

Temperature and material

Verify the published ceramic and terminal-material characteristics for the application.

Conductor range

Match conductor construction and cross-section to the exact terminal.

ការវាយតម្លៃអគ្គិសនី

Confirm current, voltage, insulation and clearance requirements.

Poles, pitch and mounting

Check connection count, spacing, fasteners, cover and panel arrangement.

Treat heat and connection as one system

Ceramic insulation does not remove the need to verify conductor, hardware, clearance and enclosure temperature.

Heat source and operating environment
អ៊ីElectrical rating and insulation requirement
MMounting, conductor and terminal hardware
Read the Ceramic Terminal Block selection guide

Compare published Ceramic Terminal Block series

ប្រឡោះទទេមានន័យថា តម្លៃមិនមាននៅក្នុងសេចក្តីសង្ខេបផលិតផលបច្ចុប្បន្នទេ។ សូមបើកទំព័រម៉ូដែល ឬស្នើសុំសន្លឹកទិន្នន័យបច្ចេកទេសរបស់វា មុនពេលធ្វើការកំណត់លក្ខណៈបច្ចេកទេស។.

ស៊េរីបង្គោលConductor rangeវាយតម្លៃបច្ចុប្បន្នសីតុណ្ហភាព
ប្លុកស្ថានីយសេរ៉ាមិច TB2260
TB3340 ប្លុកស្ថានីយសេរ៉ាមិច
ប្លុកស្ថានីយសេរ៉ាមិច TB4440
ប្លុកស្ថានីយសេរ៉ាមិច TB4460
ប្លុកស្ថានីយសេរ៉ាមិច TB6640
ប្លុកស្ថានីយសេរ៉ាមិច TB7760
TB8840 ប្លុកស្ថានីយសេរ៉ាមិច
ប្លុកស្ថានីយសេរ៉ាមិច TB101040
TB121240 ប្លុកស្ថានីយសេរ៉ាមិច
ប្លុកស្ថានីយសេរ៉ាមិច CTB1110
ប្លុកស្ថានីយសេរ៉ាមិច CTB1130
ប្លុកស្ថានីយសេរ៉ាមិច CTB2210
ប្លុកស្ថានីយសេរ៉ាមិច CTB2215
ប្លុកស្ថានីយសេរ៉ាមិច CTB2230
ប្លុកស្ថានីយសេរ៉ាមិច CTB2260
ប្លុកស្ថានីយសេរ៉ាមិច CTB22100
ប្លុកស្ថានីយសេរ៉ាមិច CTB3310
ប្លុកស្ថានីយសេរ៉ាមិច CTB3315
ប្លុកស្ថានីយសេរ៉ាមិច CTB3330
ប្លុកស្ថានីយសេរ៉ាមិច CTB4430
ប្លុកស្ថានីយសេរ៉ាមិច CTB5515
ប្លុកស្ថានីយសេរ៉ាមិច CTB6615
ប្លុកស្ថានីយសេរ៉ាមិច CTB8815
ប្លុកស្ថានីយសេរ៉ាមិច CTB101015
TBH22100 Ceramic Terminal Blocks
TBH44100 Ceramic Terminal Blocks
TBH66100 Ceramic Terminal Blocks

Ceramic Terminal Block Selection Questions

ចម្លើយរហ័សសម្រាប់ការប្រៀបធៀបក្រុមផលិតផលបឋម មុនពេលធ្វើការផ្ទៀងផ្ទាត់សៀគ្វីលម្អិត។.

Why use a ceramic terminal block?

Ceramic construction is selected where its published thermal, insulation or material characteristics suit the equipment requirements.

How is current capacity verified?

Use the exact product data with conductor size, terminal hardware, ambient and equipment conditions; do not infer capacity from physical size.

Are all ceramic terminal blocks suitable for the same temperature?

No. Material, terminal hardware and product design vary. Verify the published limits for the exact model.

Which conductor should be used?

Confirm conductor material, construction, cross-section, insulation and preparation from the equipment and terminal instructions.

Can ceramic terminals replace standard terminal blocks directly?

Only after checking dimensions, mounting, conductor range, electrical ratings, clearances and environmental requirements.

Need a Ceramic Terminal Block?
Let’s Match the Heat and Circuit.

Send the conductor size, current, voltage, operating temperature, poles, mounting, quantity and target market. VIOX will help narrow the relevant published series.

Request Ceramic Terminal Block Support