RCCB Manufacturer for OEM & Wholesale Supply
Source residual current circuit breakers from VIOX for distribution, private-label ranges and panel-building projects. Align the selected RCCB type with model documents, sample requirements, marking and packaging before confirming your order.

Build an RCCB supply program around your market.
Elektrik dağıtıcıları
Define your range, model documents, packaging and replenishment references.
Private-label brands
Review the product identity, marking and sample approval requirements for your brand.
Panel builders & project buyers
Specify the residual-current response and coordinate the RCCB with the circuit’s overcurrent protection.
Four RCCB families.
One clear order specification.
Choose a candidate family here. Use the RCCB selection page for the detailed ratings comparison and selector.

VKL11
Tip AC / A / ASi
Distribution ranges using Type AC, A or ASi configurations.

VKL11F
F Tipi
Type F supply for equipment with mixed-frequency residual currents.

VKL11B
Tip B / B+
Type B or B+ supply where the specified residual-current response requires it.

VKL11-EV
Type A EV / F EV
Mode 3 EV charging configurations, with variant-specific DC detection and document requirements.
Compare types, poles, current and sensitivity before choosing a model.
Compare all four RCCB familiesMake RCCB quality
checks model-specific.
Ask for the inspection and test evidence relevant to your selected configuration. The checks below define the review scope; they are not a claim that every test is performed on every unit.

Artık işletme akımı
Requested IΔn, waveform and exact RCCB type.
Evidence to request: Model-specific operating-current test conditions and results.
Çalışma süresi
Instantaneous, short-delay or selective version, where offered.
Evidence to request: Time limits and measured results identified by variant and test condition.
Test-button function
Supply voltage, connection and test-button operation.
Evidence to request: Applicable functional inspection method; not a substitute for calibrated trip testing.
Insulation & mechanical checks
Insulation verification, terminal condition and operating mechanism.
Evidence to request: Agreed inspection scope, acceptance criteria and order identification.
Kısa devre koordinasyonu
RCCB conditional rating and upstream MCB or fuse.
Evidence to request: Rating definition, voltage and required backup protection or coordination reference.
Production inspection
Checks recorded under the agreed production and order inspection plan.
Tip testi
Design or variant testing under stated standards and test conditions.
External certification
Third-party documentation covering the specific models and ratings listed in its scope.
Match the documents
to the model and market.
A standard named in a catalog does not by itself confirm a certificate. Request the document set for the exact variant before purchase approval.
VKL11
Identify AC, A or ASi, the rated values and pole arrangement. Review the applicable IEC/EN 61008-1 documentation and any destination-specific requirements.
VKL11F
Confirm the Type F response, operating conditions and exact configuration against the applicable IEC/EN 62423 and IEC/EN 61008-1 documents.
VKL11B
Identify Type B or B+ explicitly. Check the Type B document scope separately from any DIN VDE 0664-400 evidence required for a B+ variant.
VKL11-EV
Identify A-EV or F-EV and the integrated DC detection function. Request evidence for the declared 6mA maximum switch-off threshold and the standards applicable to that exact variant. Do not treat EV variants as interchangeable with Type B.
From RCCB specification
to repeat supply.
Use the same model and revision references across the sample, artwork, documentation and purchase order.
- 1
Confirm the series and market
Define RCCB type, voltage, In, IΔn, poles, quantity and destination.
- Approval reference
- Order specification brief
- 2
Review marking and packaging
Agree the model designation, rating labels, brand artwork and packaging requirements.
- Approval reference
- Artwork and packaging references
- 3
Approve the sample scope
Specify the sample configuration and the checks required before bulk-order approval.
- Approval reference
- Sample identification and review criteria
- 4
Match the document set
Check the model, rating, variant and destination against each requested certificate or report.
- Approval reference
- Model-to-document checklist
- 5
Confirm the bulk order
Agree the technical configuration, quantity, packing and commercial terms in writing.
- Approval reference
- Approved purchase-order specification
- 6
Identify repeat-order versions
Reference the approved model, sample and artwork when ordering replenishment.
- Approval reference
- Revision-controlled reorder reference
Prepare your RCCB
sample or bulk-order request.
Send the details you have. Identify anything still to be confirmed instead of substituting assumed ratings or certificates.
Ürün konfigürasyonu
Series · RCCB type · voltage · In · IΔn · poles · timing variant · upstream protection
Market & branding
Destination · required documents · VIOX or private label · marking · packaging
Order requirements
Sample quantity · bulk quantity · expected repeat demand · requested delivery · requirement file
Confirm the model.
Align the evidence.
Approve the order.
Start with your RCCB requirements and destination market.