VIOX ELECTRIC
言語

VIOX VSP-15T/G1000 / G1500 Solar PV DC Type 1+2 Lightning Arrester (1000V / 1500V)

The VIOX VSP-15T/G1000 (1000 V DC) and VSP-15T/G1500 (1500 V DC) are heavy-duty IEC 61643-31 Type 1 + Type 2 solar photovoltaic lightning current arresters engineered for utility-scale solar farms and commercial rooftops equipped with external lightning protection systems (LPS). Rated for Iimp 6.25 kA (10/350 μs) and Imax 40 kA (8/20 μs) in a fault-tolerant Type Y (3P) 108 mm DIN-rail chassis.

VIOXシリーズ
VSP-15T/G1000 / G1500
定格電圧
1000V DC / 1500V DC
Surge Rating
Iimp 6.25 kA (10/350μs) · Imax 40 kA
標準
IEC 61643-31 · T1+T2 PV · CE / CB

概要

The VIOX VSP-15T/G1000 (1000 V DC) and VSP-15T/G1500 (1500 V DC) are heavy-duty IEC 61643-31 Type 1 + Type 2 solar photovoltaic lightning current arresters engineered for utility-scale solar farms and commercial rooftops equipped with external lightning protection systems (LPS). Rated for Iimp 6.25 kA (10/350 μs) and Imax 40 kA (8/20 μs) in a fault-tolerant Type Y (3P) 108 mm DIN-rail chassis.

特徴

  • IEC 61643-31 Type 1 + Type 2 DC lightning arrester rated Iimp 6.25 kA (10/350 μs), In 20 kA, and Imax 40 kA (8/20 μs).
  • Dedicated 1000 V DC (Up 3.5 kV) and 1500 V DC (Up 5.5 kV) ratings for ground-mount and commercial C&I solar plants with external LPS.
  • 3-pole Type Y (DC+ / PE / DC-) pluggable architecture with DC arc-quenching thermal disconnectors and remote signaling (11/12/14).
  • Heavy-duty 36 mm/pole (108 × 90 × 72 mm) housing with 6–35 mm² terminals.

仕様

VSP-15T/G1000 / G1500 Electrical & Mechanical Specifications

パラメータ仕様
SPD ClassificationPV Type 1 + Type 2 (T1+T2) DC · IEC 61643-31 / EN 50539-11
Max Continuous Operating Voltage (Ucpv)1000 V DC (VSP-15T/G1000) · 1500 V DC (VSP-15T/G1500)
Lightning Impulse Current (Iimp, 10/350 μs)6.25 kA (per pole) / 12.5 kA (total)
Nominal / Max Discharge Current (8/20 μs)In 20 kA · Imax 40 kA
電圧保護レベル(Up)1000V DC: 3.5 kV · 1500V DC: 5.5 kV
Topology & ResponseType Y (3P: DC+ / PE / DC-) · <25 ns · Icpv ≤0.2 mA
Dimensions & Terminals108 × 90 × 72 mm · 6–35 mm² (2.5 N·m) · 35 mm DIN rail · IP20
認証取得CE, CB, UKCA, RoHS

VSP-15T/G1000 / G1500 Available Poles & Dimensions

モデルトポロジーDimensions (W × H × D)
VSP-15T/G1000Type Y (3P)108 × 90 × 72 mm
VSP-15T/G1500Type Y (3P)108 × 90 × 72 mm

寸法と設置

VIOX VSP-15T/G1000 / G1500 Solar PV DC Type 1+2 Lightning Arrester (1000V / 1500V) Dimensional Drawing (mm)
VSP-15T/G1000 / G1500 Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Required wherever PV array frames are bonded to an external lightning protection system (LPS) or separation distance s cannot be maintained.
  • Connect PE terminal to the main equipotential bonding bar using ≥16 mm² copper conductor.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

よくあるご質問

When do I need PV Type 1+2 (VSP-15T/G) instead of PV Type 2 (VSP-40/G)?

Specify VSP-15T/G whenever the building or solar plant has an external lightning protection system (lightning rods/mesh) or direct-strike exposure, as Type 2 SPDs are not tested for 10/350 μs partial lightning currents.

製品の見積もりが必要ですか?
私たちと一緒に作り上げましょう。.

製品モデル、技術定格、数量、およびOEM要件をお送りください。当社のチームがお客様の用途を確認し、1営業日以内に回答いたします。.

見積依頼