The VIOX VSP-15T/G1000 (1000 V DC) and VSP-15T/G1500 (1500 V DC) are heavy-duty IEC 61643-31 Type 1 + Type 2 solar photovoltaic lightning current arresters engineered for utility-scale solar farms and commercial rooftops equipped with external lightning protection systems (LPS). Rated for Iimp 6.25 kA (10/350 μs) and Imax 40 kA (8/20 μs) in a fault-tolerant Type Y (3P) 108 mm DIN-rail chassis.
الميزات
- IEC 61643-31 Type 1 + Type 2 DC lightning arrester rated Iimp 6.25 kA (10/350 μs), In 20 kA, and Imax 40 kA (8/20 μs).
- Dedicated 1000 V DC (Up 3.5 kV) and 1500 V DC (Up 5.5 kV) ratings for ground-mount and commercial C&I solar plants with external LPS.
- 3-pole Type Y (DC+ / PE / DC-) pluggable architecture with DC arc-quenching thermal disconnectors and remote signaling (11/12/14).
- Heavy-duty 36 mm/pole (108 × 90 × 72 mm) housing with 6–35 mm² terminals.
المواصفات
VSP-15T/G1000 / G1500 Electrical & Mechanical Specifications
| المعلمة | المواصفات |
|---|---|
| SPD Classification | PV Type 1 + Type 2 (T1+T2) DC · IEC 61643-31 / EN 50539-11 |
| Max Continuous Operating Voltage (Ucpv) | 1000 V DC (VSP-15T/G1000) · 1500 V DC (VSP-15T/G1500) |
| Lightning Impulse Current (Iimp, 10/350 μs) | 6.25 kA (per pole) / 12.5 kA (total) |
| Nominal / Max Discharge Current (8/20 μs) | In 20 kA · Imax 40 kA |
| مستوى حماية الجهد (Up) | 1000V DC: 3.5 kV · 1500V DC: 5.5 kV |
| Topology & Response | Type Y (3P: DC+ / PE / DC-) · <25 ns · Icpv ≤0.2 mA |
| Dimensions & Terminals | 108 × 90 × 72 mm · 6–35 mm² (2.5 N·m) · 35 mm DIN rail · IP20 |
| الشهادات | CE, CB, UKCA, RoHS |
VSP-15T/G1000 / G1500 Available Poles & Dimensions
| الطراز | الطوبولوجيا | Dimensions (W × H × D) |
|---|---|---|
| VSP-15T/G1000 | Type Y (3P) | 108 × 90 × 72 mm |
| VSP-15T/G1500 | Type Y (3P) | 108 × 90 × 72 mm |
الأبعاد والتركيب

- Required wherever PV array frames are bonded to an external lightning protection system (LPS) or separation distance s cannot be maintained.
- Connect PE terminal to the main equipotential bonding bar using ≥16 mm² copper conductor.
- Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.
الأسئلة الشائعة
When do I need PV Type 1+2 (VSP-15T/G) instead of PV Type 2 (VSP-40/G)?
Specify VSP-15T/G whenever the building or solar plant has an external lightning protection system (lightning rods/mesh) or direct-strike exposure, as Type 2 SPDs are not tested for 10/350 μs partial lightning currents.