VIOX ELECTRIC
Langue

VIOX VSP-15T/G1000 / G1500 Solar PV DC Type 1+2 Lightning Arrester (1000V / 1500V)

The VIOX VSP-15T/G1000 (1000 V DC) and VSP-15T/G1500 (1500 V DC) are heavy-duty IEC 61643-31 Type 1 + Type 2 solar photovoltaic lightning current arresters engineered for utility-scale solar farms and commercial rooftops equipped with external lightning protection systems (LPS). Rated for Iimp 6.25 kA (10/350 μs) and Imax 40 kA (8/20 μs) in a fault-tolerant Type Y (3P) 108 mm DIN-rail chassis.

Série VIOX
VSP-15T/G1000 / G1500
Tension nominale
1000V DC / 1500V DC
Surge Rating
Iimp 6.25 kA (10/350μs) · Imax 40 kA
Standard
IEC 61643-31 · T1+T2 PV · CE / CB

Vue d'ensemble

The VIOX VSP-15T/G1000 (1000 V DC) and VSP-15T/G1500 (1500 V DC) are heavy-duty IEC 61643-31 Type 1 + Type 2 solar photovoltaic lightning current arresters engineered for utility-scale solar farms and commercial rooftops equipped with external lightning protection systems (LPS). Rated for Iimp 6.25 kA (10/350 μs) and Imax 40 kA (8/20 μs) in a fault-tolerant Type Y (3P) 108 mm DIN-rail chassis.

Caractéristiques

  • IEC 61643-31 Type 1 + Type 2 DC lightning arrester rated Iimp 6.25 kA (10/350 μs), In 20 kA, and Imax 40 kA (8/20 μs).
  • Dedicated 1000 V DC (Up 3.5 kV) and 1500 V DC (Up 5.5 kV) ratings for ground-mount and commercial C&I solar plants with external LPS.
  • 3-pole Type Y (DC+ / PE / DC-) pluggable architecture with DC arc-quenching thermal disconnectors and remote signaling (11/12/14).
  • Heavy-duty 36 mm/pole (108 × 90 × 72 mm) housing with 6–35 mm² terminals.

Spécifications

VSP-15T/G1000 / G1500 Electrical & Mechanical Specifications

ParamètreSpécification
SPD ClassificationPV Type 1 + Type 2 (T1+T2) DC · IEC 61643-31 / EN 50539-11
Max Continuous Operating Voltage (Ucpv)1000 V DC (VSP-15T/G1000) · 1500 V DC (VSP-15T/G1500)
Lightning Impulse Current (Iimp, 10/350 μs)6.25 kA (per pole) / 12.5 kA (total)
Nominal / Max Discharge Current (8/20 μs)In 20 kA · Imax 40 kA
Niveau de protection de tension (Up)1000V DC: 3.5 kV · 1500V DC: 5.5 kV
Topology & ResponseType Y (3P: DC+ / PE / DC-) · <25 ns · Icpv ≤0.2 mA
Dimensions & Terminals108 × 90 × 72 mm · 6–35 mm² (2.5 N·m) · 35 mm DIN rail · IP20
CertificationsCE, CB, UKCA, RoHS

VSP-15T/G1000 / G1500 Available Poles & Dimensions

ModèleTopologieDimensions (W × H × D)
VSP-15T/G1000Type Y (3P)108 × 90 × 72 mm
VSP-15T/G1500Type Y (3P)108 × 90 × 72 mm

Dimensions et Installation

VIOX VSP-15T/G1000 / G1500 Solar PV DC Type 1+2 Lightning Arrester (1000V / 1500V) Dimensional Drawing (mm)
VSP-15T/G1000 / G1500 Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Required wherever PV array frames are bonded to an external lightning protection system (LPS) or separation distance s cannot be maintained.
  • Connect PE terminal to the main equipotential bonding bar using ≥16 mm² copper conductor.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

FAQ

When do I need PV Type 1+2 (VSP-15T/G) instead of PV Type 2 (VSP-40/G)?

Specify VSP-15T/G whenever the building or solar plant has an external lightning protection system (lightning rods/mesh) or direct-strike exposure, as Type 2 SPDs are not tested for 10/350 μs partial lightning currents.

Besoin d'un devis produit ?
Construisons-le ensemble.

Envoyez-nous le modèle du produit, les caractéristiques techniques, la quantité et les exigences OEM. Notre équipe examinera votre demande et vous répondra dans un délai d'un jour ouvré.

Demander un Devis