VIOX ELECTRIC
Bahasa

VIOX VSP-15T/G1000 / G1500 Solar PV DC Type 1+2 Lightning Arrester (1000V / 1500V)

The VIOX VSP-15T/G1000 (1000 V DC) and VSP-15T/G1500 (1500 V DC) are heavy-duty IEC 61643-31 Type 1 + Type 2 solar photovoltaic lightning current arresters engineered for utility-scale solar farms and commercial rooftops equipped with external lightning protection systems (LPS). Rated for Iimp 6.25 kA (10/350 μs) and Imax 40 kA (8/20 μs) in a fault-tolerant Type Y (3P) 108 mm DIN-rail chassis.

Seri VIOX
VSP-15T/G1000 / G1500
Tegangan pengenal
1000V DC / 1500V DC
Surge Rating
Iimp 6.25 kA (10/350μs) · Imax 40 kA
Standar
IEC 61643-31 · T1+T2 PV · CE / CB

Ikhtisar

The VIOX VSP-15T/G1000 (1000 V DC) and VSP-15T/G1500 (1500 V DC) are heavy-duty IEC 61643-31 Type 1 + Type 2 solar photovoltaic lightning current arresters engineered for utility-scale solar farms and commercial rooftops equipped with external lightning protection systems (LPS). Rated for Iimp 6.25 kA (10/350 μs) and Imax 40 kA (8/20 μs) in a fault-tolerant Type Y (3P) 108 mm DIN-rail chassis.

Fitur

  • IEC 61643-31 Type 1 + Type 2 DC lightning arrester rated Iimp 6.25 kA (10/350 μs), In 20 kA, and Imax 40 kA (8/20 μs).
  • Dedicated 1000 V DC (Up 3.5 kV) and 1500 V DC (Up 5.5 kV) ratings for ground-mount and commercial C&I solar plants with external LPS.
  • 3-pole Type Y (DC+ / PE / DC-) pluggable architecture with DC arc-quenching thermal disconnectors and remote signaling (11/12/14).
  • Heavy-duty 36 mm/pole (108 × 90 × 72 mm) housing with 6–35 mm² terminals.

Spesifikasi

VSP-15T/G1000 / G1500 Electrical & Mechanical Specifications

ParameterSpesifikasi
SPD ClassificationPV Type 1 + Type 2 (T1+T2) DC · IEC 61643-31 / EN 50539-11
Max Continuous Operating Voltage (Ucpv)1000 V DC (VSP-15T/G1000) · 1500 V DC (VSP-15T/G1500)
Lightning Impulse Current (Iimp, 10/350 μs)6.25 kA (per pole) / 12.5 kA (total)
Nominal / Max Discharge Current (8/20 μs)In 20 kA · Imax 40 kA
Tingkat Perlindungan Tegangan (Up)1000V DC: 3.5 kV · 1500V DC: 5.5 kV
Topology & ResponseType Y (3P: DC+ / PE / DC-) · <25 ns · Icpv ≤0.2 mA
Dimensions & Terminals108 × 90 × 72 mm · 6–35 mm² (2.5 N·m) · 35 mm DIN rail · IP20
SertifikasiCE, CB, UKCA, RoHS

VSP-15T/G1000 / G1500 Available Poles & Dimensions

ModelTopologiDimensions (W × H × D)
VSP-15T/G1000Type Y (3P)108 × 90 × 72 mm
VSP-15T/G1500Type Y (3P)108 × 90 × 72 mm

Dimensi & Instalasi

VIOX VSP-15T/G1000 / G1500 Solar PV DC Type 1+2 Lightning Arrester (1000V / 1500V) Dimensional Drawing (mm)
VSP-15T/G1000 / G1500 Outline & DIN-Rail Mounting Dimensions (unit: mm)
  • Required wherever PV array frames are bonded to an external lightning protection system (LPS) or separation distance s cannot be maintained.
  • Connect PE terminal to the main equipotential bonding bar using ≥16 mm² copper conductor.
  • Explore the complete VIOX Surge Protection Devices (SPD) catalog for matched AC, Solar PV DC, and SCB backup protection.

PERTANYAAN YANG SERING DIAJUKAN

When do I need PV Type 1+2 (VSP-15T/G) instead of PV Type 2 (VSP-40/G)?

Specify VSP-15T/G whenever the building or solar plant has an external lightning protection system (lightning rods/mesh) or direct-strike exposure, as Type 2 SPDs are not tested for 10/350 μs partial lightning currents.

Butuh Penawaran Produk?
Mari Kita Bangun Bersama.

Kirimkan model produk, peringkat teknis, kuantitas, dan persyaratan OEM kepada kami. Tim kami akan meninjau aplikasi Anda dan merespons dalam satu hari kerja.

Minta Penawaran