VIOX ELECTRIC
언어

VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector

HR17 400A 3P VIOX YR:HR17-690VAC 400A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside.

VIOX 시리즈
HR17
정격 전압
690VAC
정격 전류
400A
준
IEC 60269

개요

HR17 400A 3P VIOX YR:HR17-690VAC 400A Horizontal 3P Fuse Switch Disconnector is suitable for short circuit protection and overload protection of cable and power equipment of the distribution system. In the case of a short circuit, the current can be broken by the fuse link inside. With the features of high isolating function and high durability, YR:HR17-400/3 Horizontal Fuse switch disconnector can withstand high short circuits.

690VAC 400A Horizontal 3P Fuse Switch Disconnector

특징

  • IEC60947-3
  • Rated voltage 690VAC and current capacity 400A for hrc fuse switch disconnector applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC 60269 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.
  • Direct OEM replacement geometry for standardized industrial, solar PV, ESS, and EV protection panels.

사양

HR17 Technical Specifications

Model / Size 정격 전압(V) 정격 전류(A) Power Frequency Withstand Voltage (V) Recommended Fuse Link Model/Size 전체 차원
A E H H1 B
YR:HR17-400/3 690V 400A 3000V NT2,NH2 288 210 126 335 130

Selection & Installation Notes

  • Verify system maximum voltage (690VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

자주 묻는 질문

What voltage and current ratings does the VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector support?

This VIOX HR17 series is rated for 690VAC with a current rating of 400A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector?

The HR17 series is designed and verified to IEC 60269 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX HR17 690VAC 400A Horizontal 3P Fuse Switch Disconnector typically installed?

It is engineered for hrc fuse switch disconnector circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

제품 견적이 필요하신가요?
함께 만들어 갑시다.

제품 모델, 기술 정격, 수량 및 OEM 요구 사항을 보내주십시오. 당사 팀에서 귀하의 애플리케이션을 검토한 후 영업일 기준 1일 이내에 답변해 드리겠습니다.