Protection, switching and distribution for residential, industrial, solar, data, panel and marine projects.

Conceptual 3D industrial park with residential buildings, a factory, solar and storage, a data center, a central distribution frame, an EV charging court, and a marine dock

Explore the applications below.

애플리케이션

주거용 건물

Residential distribution boards bring together protection for lighting, socket outlets, kitchens and climate-control circuits. MCBs provide overload and short-circuit protection; RCCBs provide residual-current protection and require coordinated overcurrent protection; RCBOs combine these functions at the circuit level. Choose the current rating, tripping curve, pole configuration and breaking capacity for each circuit. Select the residual-current type for the connected equipment rather than treating Type B or EV variants as a default requirement for every home. Separating final circuits can limit disruption from a fault, while continuity still depends on upstream coordination. Surge protective devices address transient overvoltages and do not replace circuit breakers. Prepare the supply details, circuit schedule, destination market, required documents, board-space limits and order scope before confirming a model.

태양광 및 에너지 저장

PV strings, combiner boxes, DC isolation and surge protection form different parts of the solar power path. A correctly specified gPV fuse and compatible holder protect individual strings, while a PV surge protective device limits transient overvoltage through a coordinated path to earth. A DC isolator provides a defined manual isolation point. Confirm voltage, current, pole arrangement, earthing and interruption requirements against the array design and the selected device. Review the complete combiner assembly and its model-specific component list before ordering. Battery-side protection is a separate design decision: bidirectional current, maximum DC voltage, prospective fault current and the battery or PCS instructions must be checked before using a PV-oriented component. Share the system architecture, string layout, environmental exposure, quantity and document requirements to prepare a product request.

산업 자동화

Industrial control components sense conditions, manage timing, switch loads and protect circuits within a defined machine operating sequence. A contactor operates the load in response to the control circuit; confirm motor duty, utilization category, coil voltage and switching frequency together with overload and short-circuit protection. Proximity sensors require a match between target material, sensing distance, supply voltage and controller input. Timer relays require the operating mode, trigger, reset behavior, time range and output contact duty to be specified. Cabinet thermostats control selected heating or cooling arrangements within their declared switching and temperature limits. Machine interlocks and controller logic remain part of the control-system design. Prepare the power supply, control voltage, load data, sensing requirements, panel environment and order scope before selecting individual components.

데이터 센터 및 통신

Data center and telecom power systems coordinate source transfer, monitoring, surge protection and auxiliary distribution around the actual electrical design. Normal and alternate supplies, transfer equipment, distribution, UPS architecture and downstream loads form a wider system; UPS and rack PDU nodes are context, not presented as VIOX products. Automatic transfer switches manage defined source changes, monitoring relays provide control signals, and AC surge protective devices limit transient overvoltage at coordinated positions. MCBs protect selected branch circuits, while distribution blocks and terminal blocks organize conductors. Confirm source arrangement, neutral treatment, interlocking, fault level and protection boundaries. Follow the UPS manufacturer's requirements at its interfaces. Share system ratings, monitoring thresholds, control voltage, earthing, panel conditions and model-document needs before confirming a component shortlist.

해양 및 옥외용 전기 설비

Outdoor equipment protection depends on the enclosure, lid, cable entries, closures and any specified vent working together. Match cable glands to cable outside diameter, cable count, thread type, wall thickness and strain-relief requirements. Select enclosure material, usable space, lid seal and mounting arrangement for the complete installation. A breather vent may support pressure equalization where the enclosure design calls for it, but does not guarantee freedom from condensation. Keep conductor terminations accessible for inspection and resealing. Sheltered cabinets, coastal equipment, wet industrial areas and temporary outdoor power face different exposure conditions. Review rain, dust, sunlight, chemicals, corrosion and vibration, and verify any required marine approvals for the exact model. Provide electrical ratings, cable sizes, exposure conditions, quantities and destination requirements for product review.

패널 제작 및 배전

Low-voltage panel building organizes incoming conductors, main distribution, branch protection, modular mounting and outgoing terminals into a defined current path. Distribution blocks split conductors, busbar assemblies support distribution, DIN rails mount compatible components, and terminal blocks provide identified outgoing connections. Assign each zone a clear function and confirm conductor material, cross-section, connection method and service access. Protective devices require coordinated ratings, pole arrangements, neutral treatment and compatible busbar interfaces. Mechanical selection includes enclosure space, mounting profiles, busbar supports and clearances. The panel builder remains responsible for complete design, protection coordination, temperature-rise assessment, short-circuit performance and applicable documentation; a component layout is not assembly verification. Share the single-line concept, electrical system, current paths, dimensions, product quantities and destination market before confirming the component list.

Application questions

주거용 프로젝트나 제품군을 계획 중이신가요?

회로 일정 또는 소싱 요구 사항을 VIOX ELECTRIC와 공유해 주십시오.

Source: applications/residential-buildings

태양광 PV 또는 배터리 DC 시스템을 계획 중이신가요?

시스템 전압, 전류, 스트링 레이아웃, 보호 범위, 설치 환경 및 대상 시장을 VIOX ELECTRIC와 공유해 주십시오.

Source: applications/solar-energy-storage

산업용 제어 패널을 구축 중이신가요?

부하, 제어 전압, 작동 순서, 감지 요구 사항 및 주문 범위를 VIOX ELECTRIC와 공유해 주십시오.

Source: applications/industrial-automation

데이터 센터 또는 통신용 전원 패널을 정의하십니까?

전원 구성, 전기 정격, 모니터링 기능, 보호 경계, 프로젝트 시장 및 주문 범위를 VIOX ELECTRIC와 공유해 주십시오.

Source: applications/data-centers-telecom

실외 전기 인클로저를 계획 중이신가요?

케이블 크기, 외함 세부 정보, 노출 조건 및 수량을 보내주십시오. VIOX ELECTRIC가 구성 요소 옵션을 좁히는 데 도움을 드릴 수 있습니다.

Source: applications/marine-outdoor-electrical