VIOX Electric
Language

태양광 PV 결합기 박스

Compare published VIOX solar PV combiner boxes by system-voltage class and input/output string layout for organized DC string collection, protection and isolation.

600V / 1000VPublished system classes

1–8 string rangeMatch array architecture

DC protectionCoordinate fuse, SPD and isolation

Enclosure assemblyVerify entries and environment

What is a solar combiner box?

A solar combiner box collects the output of multiple photovoltaic strings into one or more outgoing DC circuits before connection to downstream isolation, inverter or distribution equipment.

The complete assembly may coordinate string fuses, surge protection, DC isolation, terminals and monitoring. Selection depends on array voltage, string current and count, reverse-current conditions, protection architecture, enclosure environment and cable-entry layout.

PV strings enterIndividual string conductors arrive through planned DC cable entries.
Protection is coordinatedFuses, SPD and isolation are matched to the array and system design.
Combined output leavesThe organized DC output connects to the next approved device or inverter input.

How to choose a solar combiner box

Map the PV strings and electrical protection first, then select the enclosure and field interface.

Maximum DC voltage

Use the array open-circuit voltage at the lowest design temperature and the exact equipment rating.

String count and current

Confirm input/output layout, string current, conductor size and reverse-current protection.

Fuse, SPD and isolator coordination

Specify each protective function from the array architecture and applicable design rules.

인클로저 및 케이블 인입구

Check material, protection, heat, UV exposure, gland layout, mounting and service access.

Coordinate the complete PV collection point

The enclosure, strings, fuses, SPD, isolator, conductors and downstream equipment form one DC protection system.

AArray voltage, current and string count
PProtection and isolation architecture
EEnclosure, entries and environment
Read the Combiner Box selection guide

Compare published Combiner Box series

빈 셀은 현재 제품 요약에서 해당 값을 사용할 수 없음을 의미합니다. 사양을 확인하기 전에 모델 페이지를 열거나 데이터시트를 요청하십시오.

시리즈시스템 전압String layout시스템
VOPV600-1/1 태양광 접속함600V 직류1 입력 / 1 출력600V 직류
VOPV600-2/2 태양광 접속함600V 직류2 입력 / 2 출력600V 직류
VOPV1000-1/1 태양광 접속함1000V DC1 입력 / 1 출력1000V DC
VOPV1000-2/2 태양광 접속함1000V DC2 입력 / 2 출력1000V DC
VOPV1000-3/1 태양광 결합 박스1000V DC3 입력 / 1 출력1000V DC
VOPV1000-3/3 태양광 접속함1000V DC3 입력 / 3 출력1000V DC
VCB F4/1 DC PV Combiner Box4 입력 / 1 출력Solar PV / DC
VCB F6/1 DC PV Combiner Box6 입력 / 1 출력Solar PV / DC
VCB F8/1 DC PV Combiner Box8 입력 / 1 출력Solar PV / DC

Combiner Box Selection Questions

상세 회로 검증 전 제품군 비교를 위한 빠른 답변.

When is a PV combiner box needed?

It is commonly considered when multiple PV strings must be collected and their protection, isolation or monitoring organized before downstream equipment. The exact need depends on the system architecture.

How is the voltage class selected?

Calculate the maximum array open-circuit voltage at the lowest design temperature and select every component for the resulting DC system conditions.

How many strings should the box accept?

Match the actual and planned string count, current, conductor layout, inverter inputs and protection design without exceeding the published enclosure configuration.

Which protective devices belong inside?

The design may include string fuses, DC SPD and isolation, but the required combination depends on array and system coordination.

Does the enclosure rating apply after cable entry?

The complete installed assembly, including glands, plugs, seals, mounting and workmanship, determines final environmental protection.

Need a Solar Combiner Box?
Let’s Map the PV Strings.

Send the maximum DC voltage, string current and count, input/output layout, protection requirements, enclosure environment, quantity and target market.

Request Combiner Box Support