태양광 PV 결합기 박스
Compare published VIOX solar PV combiner boxes by system-voltage class and input/output string layout for organized DC string collection, protection and isolation.
600V / 1000VPublished system classes
1–8 string rangeMatch array architecture
DC protectionCoordinate fuse, SPD and isolation
Enclosure assemblyVerify entries and environment
What is a solar combiner box?
A solar combiner box collects the output of multiple photovoltaic strings into one or more outgoing DC circuits before connection to downstream isolation, inverter or distribution equipment.
The complete assembly may coordinate string fuses, surge protection, DC isolation, terminals and monitoring. Selection depends on array voltage, string current and count, reverse-current conditions, protection architecture, enclosure environment and cable-entry layout.
Solar Combiner Box Series Overview
Compare the nine published VIOX products. Cards show only facts explicit in current product data or model titles.

VOPV600-1/1 태양광 접속함
태양광 PV 결선함(컴바이너 박스)- 시스템 전압
- 600V 직류
- String layout
- 1 입력 / 1 출력
- 시스템
- Solar PV / DC

VOPV600-2/2 태양광 접속함
태양광 PV 결선함(컴바이너 박스)- 시스템 전압
- 600V 직류
- String layout
- 2 입력 / 2 출력
- 시스템
- Solar PV / DC

VOPV1000-1/1 태양광 접속함
태양광 PV 결선함(컴바이너 박스)- 시스템 전압
- 1000V DC
- String layout
- 1 입력 / 1 출력
- 시스템
- Solar PV / DC

VOPV1000-2/2 태양광 접속함
태양광 PV 결선함(컴바이너 박스)- 시스템 전압
- 1000V DC
- String layout
- 2 입력 / 2 출력
- 시스템
- Solar PV / DC

VOPV1000-3/1 태양광 결합 박스
태양광 PV 결선함(컴바이너 박스)- 시스템 전압
- 1000V DC
- String layout
- 3 입력 / 1 출력
- 시스템
- Solar PV / DC

VOPV1000-3/3 태양광 접속함
태양광 PV 결선함(컴바이너 박스)- 시스템 전압
- 1000V DC
- String layout
- 3 입력 / 3 출력
- 시스템
- Solar PV / DC

VCB F4/1 DC PV Combiner Box
태양광 PV 결선함(컴바이너 박스)- String layout
- 4 입력 / 1 출력
- 시스템
- Solar PV / DC

VCB F6/1 DC PV Combiner Box
태양광 PV 결선함(컴바이너 박스)- String layout
- 6 입력 / 1 출력
- 시스템
- Solar PV / DC

VCB F8/1 DC PV Combiner Box
태양광 PV 결선함(컴바이너 박스)- String layout
- 8 입력 / 1 출력
- 시스템
- Solar PV / DC
How to choose a solar combiner box
Map the PV strings and electrical protection first, then select the enclosure and field interface.
Maximum DC voltage
Use the array open-circuit voltage at the lowest design temperature and the exact equipment rating.
String count and current
Confirm input/output layout, string current, conductor size and reverse-current protection.
Fuse, SPD and isolator coordination
Specify each protective function from the array architecture and applicable design rules.
인클로저 및 케이블 인입구
Check material, protection, heat, UV exposure, gland layout, mounting and service access.
Coordinate the complete PV collection point
The enclosure, strings, fuses, SPD, isolator, conductors and downstream equipment form one DC protection system.
Compare published Combiner Box series
빈 셀은 현재 제품 요약에서 해당 값을 사용할 수 없음을 의미합니다. 사양을 확인하기 전에 모델 페이지를 열거나 데이터시트를 요청하십시오.
| 시리즈 | 시스템 전압 | String layout | 시스템 |
|---|---|---|---|
| VOPV600-1/1 태양광 접속함 | 600V 직류 | 1 입력 / 1 출력 | 600V 직류 |
| VOPV600-2/2 태양광 접속함 | 600V 직류 | 2 입력 / 2 출력 | 600V 직류 |
| VOPV1000-1/1 태양광 접속함 | 1000V DC | 1 입력 / 1 출력 | 1000V DC |
| VOPV1000-2/2 태양광 접속함 | 1000V DC | 2 입력 / 2 출력 | 1000V DC |
| VOPV1000-3/1 태양광 결합 박스 | 1000V DC | 3 입력 / 1 출력 | 1000V DC |
| VOPV1000-3/3 태양광 접속함 | 1000V DC | 3 입력 / 3 출력 | 1000V DC |
| VCB F4/1 DC PV Combiner Box | — | 4 입력 / 1 출력 | Solar PV / DC |
| VCB F6/1 DC PV Combiner Box | — | 6 입력 / 1 출력 | Solar PV / DC |
| VCB F8/1 DC PV Combiner Box | — | 8 입력 / 1 출력 | Solar PV / DC |
Combiner Box Applications
정확한 제품 사양 확인이 필요한 일반적인 환경.
Combiner Box Selection Questions
상세 회로 검증 전 제품군 비교를 위한 빠른 답변.
When is a PV combiner box needed?
It is commonly considered when multiple PV strings must be collected and their protection, isolation or monitoring organized before downstream equipment. The exact need depends on the system architecture.
How is the voltage class selected?
Calculate the maximum array open-circuit voltage at the lowest design temperature and select every component for the resulting DC system conditions.
How many strings should the box accept?
Match the actual and planned string count, current, conductor layout, inverter inputs and protection design without exceeding the published enclosure configuration.
Which protective devices belong inside?
The design may include string fuses, DC SPD and isolation, but the required combination depends on array and system coordination.
Does the enclosure rating apply after cable entry?
The complete installed assembly, including glands, plugs, seals, mounting and workmanship, determines final environmental protection.
Need a Solar Combiner Box?
Let’s Map the PV Strings.
Send the maximum DC voltage, string current and count, input/output layout, protection requirements, enclosure environment, quantity and target market.
Request Combiner Box Support