VIOX ELECTRIC
언어

VIOX RT18L-125 500VAC 125A 22×58mm DIN Rail Fuse Holder

RT18L-125 VIOX Electric is a leading China 500VAC 125A 22×58mm DIN Rail Fuse Holder manufacturers. VIOX brand RT18L-125 22×58mm Fuse Holder is specifically designed to provide fast-acting protection under overload current conditions associated with industrial applications. The.

VIOX 시리즈
RT18L-125
정격 전압
500VAC
정격 전류
125A
준
IEC60269-1 / IEC60269-2

개요

RT18L-125 VIOX Electric is a leading China 500VAC 125A 22×58mm DIN Rail Fuse Holder manufacturers. VIOX brand RT18L-125 22×58mm Fuse Holder is specifically designed to provide fast-acting protection under overload current conditions associated with industrial applications. The recommended fuse link size is 22×58mm, which can safely protect general industrial applications. All circuits up to 690V for protection of motors, transformers, low voltage distribution, control circuits and so on. RT18L-125 22×58mm Fuse Holder was made of the flame-retardant shell with V0 standard, and the dead-front design made it possible to match the busbar mounting. RT18L-125 22×58mm Fuse Holder is also available in 1, 2, 3 and 4-pole configurations.

특징

  • IEC60269-1
  • IEC60269-2
  • Rated voltage 500VAC and current capacity 125A for low-voltage hrc industrial fuse applications.
  • High interrupting performance (High Breaking Capacity) with rapid current-limiting fault clearing.
  • Engineered and tested in accordance with IEC60269-1 / IEC60269-2 standards.
  • Precision-engineered low-power-loss silver-plated contacts and high-temperature ceramic or flame-retardant housing.

사양

RT18L-125 Technical Specifications

Product code 정격 전류 정격 전압 Recommended Fuse Link Model/Size Net weight
RT18L-125 125A 380VAC 500VAC RT18L-125(Φ22.2×58)mm 182g

Selection & Installation Notes

  • Verify system maximum voltage (500VAC) and prospective short-circuit fault current before selecting the fuse link or holder rating.
  • Apply ambient-temperature derating when operating inside sealed outdoor combiner boxes or high-density inverter cabinets above 40°C.
  • Always de-energize circuits before replacing cylindrical, blade, or bolted fuse links, and use insulated fuse pullers for NH/NT types.
  • Explore the complete VIOX Fuse & Fuse Holder catalog for matched holders, bases, and disconnectors.

자주 묻는 질문

What voltage and current ratings does the VIOX RT18L-125 500VAC 125A 22×58mm DIN Rail Fuse Holder support?

This VIOX RT18L-125 series is rated for 500VAC with a current rating of 125A and High Breaking Capacity breaking performance. Refer to the technical specification table above for individual part numbers and ampere steps.

Which international standards apply to VIOX RT18L-125 500VAC 125A 22×58mm DIN Rail Fuse Holder?

The RT18L-125 series is designed and verified to IEC60269-1 / IEC60269-2 requirements for safe overcurrent and short-circuit protection.

Where is the VIOX RT18L-125 500VAC 125A 22×58mm DIN Rail Fuse Holder typically installed?

It is engineered for low-voltage hrc industrial fuse circuits, protecting cables, busbars, semiconductors, battery modules, or string feeders against thermal overload and high-energy short-circuit faults.

Can VIOX supply matched fuse holders, bases, or OEM private-label packaging?

Yes. VIOX Electric supplies matched DIN-rail fuse holders, NH/NT fuse bases, disconnectors, and OEM/ODM bulk packaging with technical datasheets upon RFQ.

제품 견적이 필요하신가요?
함께 만들어 갑시다.

제품 모델, 기술 정격, 수량 및 OEM 요구 사항을 보내주십시오. 당사 팀에서 귀하의 애플리케이션을 검토한 후 영업일 기준 1일 이내에 답변해 드리겠습니다.

견적 요청하기