VIOX ELECTRIC
Dil
Direct Factory · IEC 61238-1 & DIN 46235 Compression Lug Manufacturer

Cable Lugs (Copper, Bimetallic & Aluminum) 99.9% T2 Copper, Friction-Welded Cu-Al DTL & DIN Aluminum Compression Terminals

Engineered for zero-hotspot power terminations in switchgear, transformers, solar combiner boxes, and industrial panels. VIOX manufactures 16 compression lug series spanning 1.5 – 1,000 mm² across tinned copper (SC, DT, DTS, JG, OT, C45), friction-welded bimetallic (DTL-1/2/2S/3/5/8), and pure aluminum (DL, AU).

1.5 – 1,000 mm²Metric & AWG Conductor Range
99.9% T2 CopperBare & Electro-Tin Plated
Cu-Al Friction WeldZero Galvanic Corrosion DTL
VIOX Full Range of Copper, Bimetallic DTL and Aluminum Cable Lugs
01 · Complete Compression Lug Catalog (16 Real Factory Series)

Browse VIOX Copper, Bimetallic Cu-Al & Aluminum Cable Lugs

Filter by metallurgy family below to inspect dimensional drawings and datasheets, or compare all five structural series in the reference matrix.

Engineering selection matrix: VIOX Copper, Friction-Welded Bimetallic & Aluminum Cable Lug Families
Series Family Metallurgy & Plating Conductor Range Barrel & Palm Feature Birincil Uygulama
SC (DTGA) Copper99.9% T2 Copper + Electro-Tin1.5 – 400 mm²Inspection peephole + chamfered entryDistribution boards, battery banks, inverters
DT / DT(G) / DTS / JGHeavy-Wall 99.9% T2 Copper10 – 1,000 mm²Closed moisture-seal barrel (1-hole or 2-hole DTS)Switchgear busbars, transformers, heavy feeders
DTL-1 / 2 / 2S / 3 / 5 / 8Friction-Welded Cu Palm + Al Barrel16 – 800 mm²Pre-filled oxide-inhibiting grease + end capAluminum cable to copper busbar (anti-galvanic)
DL / AU Aluminum99.6% Electrical Grade Aluminum16 – 630 mm²Long compression barrel (DIN 46329 AU option)Aluminum cable to aluminum busbar / stud
OT & C45 Insert-inStamped / Tin-Plated T2 Copper1.5 – 240 mm²Open ring (OT) or flat MCB pin blade (C45)Control panels, DIN MCB/MCCB tunnel clamps
02 · Interactive Cable Cross-Section (mm² / AWG) & Metallurgy Sizer

Match VIOX Lug Series, Stud Size & Model Code to Your Cable

Slide to your cable cross-section, choose conductor-to-busbar metallurgy, and select palm type to get an instant model recommendation and bolt-hole match.

70 mm² (2/0 AWG)
2. Cable Conductor → Terminal / Busbar Metallurgy
3. Palm & Inspection Requirement
03 · Bimetallic Friction-Weld Cutaway & Failure Prevention Lab

How Friction-Welded Cu-Al Lugs & Hex Crimps Stop Terminal Burnout

Inspect the internal cross-section of a VIOX DTL bimetallic lug below, then toggle between Galvanic Corrosion and Crimping Quality comparisons.

CAD CUTAWAYFriction-Welded Bimetallic Cable Lug (DTL Series) — Internal Cross-Section
Al Cable Barrel + Hermetic Friction Weld + T2 Copper Palm
ALUMINUM CONDUCTOR SIDE (99.6% Al) COPPER BUSBAR SIDE (99.9% T2 Cu) ALUMINUM CABLE COPPER BUSBAR Hexagonal Crimp Indents Friction-Weld Bond (Hermetic) T2 Copper Palm + M10/M12 Bolt Pre-Filled Joint Compound Blocks Al Oxide Formation Cu-to-Cu Contact Interface Zero Galvanic Corrosion
LAB 01Termination Reliability & Failure Comparison

Direct Aluminum Lug on Copper Busbar

GALVANIC HOTSPOT

    VIOX Friction-Welded DTL Bimetallic Lug

    IEC 61238-1 SAFE

      99.9% Pure T2 Electrolytic Copper

      High-conductivity annealed copper tubes (≥98% IACS) eliminate cracking during deep hydraulic crimping and minimize I²R temperature rise under continuous load.

      Solid-State Friction Welding (DTL)

      Our Cu-Al bimetallic transition weld is stronger than the base aluminum metal itself—hermetically sealing the dissimilar-metal boundary from moisture.

      Clear Die-Stamped Sizing

      Every VIOX lug palm is permanently stamped with conductor mm² and stud hole size (e.g. SC70-10, DTL-2-120) for zero-error field inspection.

      04 · Direct Factory Proof · Metallurgy & Mechanical QC

      Quotation Variables, Factory QC & OEM Private-Label Supply

      In-house cold forging, friction welding, automated annealing, and bright electro-tin plating for utility EPCs, switchgear OEMs, and electrical wholesalers.

      1. Copper Purity & Conductivity

      Certified ≥99.9% T2 electrolytic copper and ≥99.6% electrical aluminum raw billets tested per batch for conductivity and ductility.

      2. Friction-Weld Bend & Pull Test

      DTL bimetallic lugs undergo destructive tensile pull-out and 90° bend tests verifying the Cu-Al weld never delaminates.

      3. Electro-Tin Plating Audit

      Uniform bright tin plating (3–5 µm) prevents surface oxidation in coastal, humid, and industrial switchgear environments.

      4. Custom Stamping & Kits

      OEM logo stamping, custom stud hole punching (M4–M20), retail polybags, or consolidated shipments with Kablo Rakorları ve Insulators.

      05 · Interactive B2B Tool · 5-Step Cable Lug RFQ Builder

      Generate Your Cable Lug RFQ in 30 Seconds

      Select series family, conductor cross-section range, bolt hole size, and packaging requirements to generate a ready-to-quote engineering brief.

      1. Cable Lug Series Family
      2. Conductor Cross-Section Range
      3. Mounting Stud Hole Size
      4. Surface Finish & Compound
      5. Supply & Packaging
      06 · Power Termination & Crimping Knowledge Hub

      Cable Lug Sizing, Crimping & Manufacturing Guides

      Technical references written by VIOX power-connection engineers to help you specify the right lug metallurgy, size, and crimping die.

      07 · Technical & Sourcing FAQ

      Cable Lug Selection, Crimping & Bimetallic Questions

      Copper vs. Bimetallic When is a bimetallic (DTL) cable lug mandatory instead of a copper or aluminum lug?

      Whenever an aluminum cable connects to a copper busbar, circuit breaker terminal, or transformer stud, a friction-welded bimetallic lug (DTL-1, DTL-2, DTL-2S, DTL-5, or DTL-8) is mandatory. Bolting an aluminum lug directly onto copper in humid air triggers galvanic corrosion, increasing contact resistance and causing severe terminal overheating.

      SC vs. DT Series What is the difference between SC(DTGA) and DT copper cable lugs?

      SC(DTGA) lugs are electro-tin-plated tubular copper terminals with a built-in inspection peephole so installers can visually verify full conductor insertion before crimping—ideal for panels, batteries, and indoor switchgear (1.5–400 mm²). DT lugs feature a heavier, closed-barrel forged/tubular construction without a peephole to block moisture ingress in outdoor and high-current feeders up to 1,000 mm².

      Sizing & Studs How do I read VIOX cable lug model numbers like SC70-10 or DTL-2-120?

      In SC70-10, "SC" denotes the tinned inspection-window copper series, "70" is the conductor cross-section in mm² (70 mm² ≈ 2/0 AWG), and "10" is the M10 palm mounting bolt hole diameter (10.5 mm clearance). In DTL-2-120, "DTL-2" is the round-palm friction-welded bimetallic series and "120" is the 120 mm² aluminum conductor barrel size.

      Crimping Standard Why is hexagonal hydraulic crimping preferred over soldering for power cable lugs?

      Hexagonal compression crimping (per IEC 61238-1) cold-welds conductor strands and barrel walls into a gas-tight, low-resistance mechanical joint that survives short-circuit thermal shocks. Soldered joints can melt under fault currents, wick up flexible strands causing vibration fatigue, and leave flux residues that corrode copper over time.

      Two-Hole Palms When should I specify a two-hole lug like DTS or DTL-3 instead of a single-hole lug?

      Specify two-hole lugs (DTS copper or DTL-3 bimetallic) on high-vibration equipment (generators, traction motors, wind turbines), medium-voltage switchgear, and heavy parallel feeders (≥ 150 mm²) where cable weight could twist a single-bolt palm and loosen contact pressure.

      Joint Compound Do VIOX bimetallic and aluminum cable lugs come pre-filled with oxide-inhibiting grease?

      Yes. VIOX DTL bimetallic and DL/AU aluminum barrels are pre-filled with neutral oxide-inhibiting joint compound and sealed with a color-coded end cap to prevent aluminum oxide formation during storage and ensure low contact resistance immediately after crimping.

      Direct Engineering & OEM Support

      Need a Complete Cable Lug Size Chart or Factory Quote?

      Send your BOM with conductor mm²/AWG sizes, Cu/Al/Bimetallic requirements, and bolt hole diameters. VIOX factory engineers reply with dimensional tables, samples, and tiered pricing within 24 hours.

      16 Copper, DTL & Aluminum Series 1.5 – 1,000 mm² Full Tooling IEC 61238-1 & OEM Stamping