VIOX Điện
Language

RCBO loại A/AC/ASi VRL22

The VIOX VRL22 RCBO combines residual-current, overload and short-circuit protection for AC 50/60 Hz circuits. It supports 2-63 A rated currents, 10-500 mA residual-current options, B, C and D tripping curves, and 1P+N or 3P+N configurations. Type AC, A, ASi, A G and A S versions are available for residential, commercial and light industrial distribution systems.

Bình Hiện Tại
2-63 A
Dòng rò (Residual Current)
10-500 mA
Cấu hình cực
1P+N, 3P+N
Khả Năng Phá Vỡ
6 kA hoặc 10 kA

Tổng quan

The VIOX VRL22 is an electromagnetic, voltage-independent residual current circuit breaker with overcurrent protection. It combines residual-current, overload and short-circuit protection for AC 50/60 Hz circuits. Available configurations include Type AC, Type A, Type ASi, Type A G short-time-delayed and Type A S selective versions. The series covers 1P+N circuits at 230/240 V AC and 3P+N circuits at 400/415 V AC. It is intended for residential, commercial and light industrial distribution systems and may also be used for infrequent switching under normal operating conditions.

Đặc trưng

  • Residual-current, overload and short-circuit protection in one device.
  • Electromagnetic, voltage-independent operating principle.
  • Type AC, A, ASi, A G short-time-delayed and A S selective options.
  • B, C and D overcurrent tripping curves.
  • Rated short-circuit breaking capacity of 6 kA or 10 kA.
  • Top or bottom power entry.
  • 5,000-cycle electrical and mechanical endurance.

Mô hình

Người mẫu Cấu hình Maximum Rated Current Điện áp định mức
VRL22 1P+N 63 A 230/240 V AC
VRL22-40 3P+N 40 A 400/415 V AC
VRL22-63 3P+N 63 A 400/415 V AC

Thông số kỹ thuật

Electrical Data

Tham sốĐặc điểm kỹ thuật
Dòng điện định mức của khung63 A
Bình Hiện Tại2, 4, 5, 6, 8, 10, 13, 15, 16, 20, 25, 30, 32, 35, 40, 45, 50, 60, 63 A
Điện áp định mức1P+N: 230/240 V AC; 3P+N: 400/415 V AC
Tần số định mức50/60 Hz
Điện áp chịu xung định mức4 kV
Hành Nguyên TắcElectromagnetic, voltage-independent

Protection Data

Tham sốĐặc điểm kỹ thuật
Residual-Current TypesType AC; Type A; Type ASi; Type A G short-time-delayed; Type A S selective
Rated Residual Operating Current10 mA for 1P+N up to 32 A only; 30, 100, 300, 500 mA
Rated Residual Non-Operating Current5 mA for 1P+N up to 32 A only; 15, 50, 150, 250 mA
Tripping CurvesB: 3-5 In; C: 5-10 In; D: 10-20 In
Rated Short-Circuit Breaking Capacity6 kA or 10 kA; energy-limiting class 3 for B and C curves
Rated Residual Making and Breaking Capacity3,000 A

Mechanical Data

Tham sốĐặc điểm kỹ thuật
Cấu hình cực1P+N; 3P+N
Độ bền điện5,000 operating cycles
Độ bền cơ học5,000 operating cycles
Power EntryTrên hoặc dưới

Tiêu chuẩn

Tham sốĐặc điểm kỹ thuật
Các tiêu chuẩn áp dụngIEC/EN 61009-1; AS/NZS 61009.1; OVE E 8601 for Type A G short-time-delayed versions

Hướng dẫn lựa chọn

Code ElementÝ nghĩaAvailable Values
VVIOX enterprise identificationV
RLRCBO product familyRL
22Design series22
Residual TypeLoại dòng dưAC, A, ASi, AG or AS
Đường cong đặc tínhĐường cong tác động quá dòngB, C or D
Hiện hànhDòng điện định mức2-63 A
Nhạy cảmDòng điện dư định mức khi vận hành10, 30, 100, 300 or 500 mA
CựcSố cực2P or 4P ordering designation

Catalog configuration example: V-RL-22-A-C-32A-30mA-1P+N

Residual Type

Select Type AC, A, ASi, A G short-time-delayed or A S selective according to the required residual-current response.

Bình Hiện Tại

Select one of the listed current ratings from 2 A to 63 A, observing the 40 A limit of the VRL22-40 model.

Residual Sensitivity

Select 10, 30, 100, 300 or 500 mA. The 10 mA option is limited to 1P+N models rated up to 32 A.

Poles and Voltage

Use 1P+N for 230/240 V AC circuits or 3P+N for 400/415 V AC circuits.

Đường cong chuyến đi

Kiểm tra dòng điệnSpecified TimeQuảApplicable Curve
1.13 Trongt ≥ 1 hNon-trippingB, C
1,45 Trongt < 1 hvấp ngãB, C
2,55 Trong1 s < t < 60 svấp ngãB, C
3 Int ≥ 0.1 sNon-trippingB
5 Int < 0.1 svấp ngãB
5 Int ≥ 0.1 sNon-trippingC
10 Int < 0.1 svấp ngãC

The catalog lists D-curve availability but provides detailed instantaneous test criteria only for B and C curves.

At IΔnAt 2 IΔnAt 5 IΔnAt IΔt
0.1 s0.05 s0.04 s0.04 s

Ứng dụng

  • Residential distribution boards.
  • Commercial building electrical distribution.
  • Light industrial distribution systems.
  • Industrial installations requiring combined residual-current and overcurrent protection.

Cài đặt

  • Match the 1P+N or 3P+N configuration to the circuit voltage and conductor arrangement.
  • Use either top or bottom power entry according to the distribution-board layout.
  • Observe the model-specific current limit when selecting VRL22, VRL22-40 or VRL22-63.

Câu hỏi thường gặp

What protection functions does the VRL22 provide?

It combines residual-current, overload and short-circuit protection.

Which residual-current types are available?

The catalog lists Type AC, Type A, Type ASi, Type A G short-time-delayed and Type A S selective versions.

What rated currents are available?

Rated-current options extend from 2 A to 63 A, with model-specific limits for the 3P+N versions.

Which residual-current sensitivities can be selected?

Available ratings are 10, 30, 100, 300 and 500 mA. The 10 mA option is limited to 1P+N models up to 32 A.

What is the available short-circuit breaking capacity?

The VRL22 is available with a rated short-circuit breaking capacity of 6 kA or 10 kA.

Need a Product Quote?
Hãy cùng chúng tôi thực hiện dự án này.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Yêu cầu báo giá