VIOX ELECTRIC
Ngôn ngữ

Tiếp điểm AC (IEC 60947-4-1)

Compare six dedicated VIOX industrial AC contactor platforms—from 6 A miniature DIN-rail units to 800 A heavy-duty motor contactors, wide-voltage AC/DC electronic coils, and 4-pole resistive switching.

6–800 A AC-34–450 kW at 380/400 V AC
AC & Electronic CoilsFixed AC 24–400 V · Wide AC/DC 24–240 V
2P / 3P / 4PIEC/EN 60947-4-1 · OEM Direct
VIOX AC contactor series collection on a white studio background

VIOX AC Contactor Series (6 Models)

Six dedicated industrial AC contactor platforms covering 6 A through 800 A AC-3 duty—select a model to inspect full specifications.

VIOX CJX2s Standard AC Contactor
Tiêu chuẩn công nghiệp

CJX2s

VIOX CJX2s Standard AC Contactor

AC-3 Rating
9–110 A
Power / Duty
4–55 kW (380/400 V)
Cực
3P
Control Coil
AC 50/60 Hz (24–400 V)
Khởi động từ AC cuộn dây điện tử VIOX CJX2s-W
Electronic Coil

CJX2s-W

Khởi động từ AC cuộn dây điện tử VIOX CJX2s-W

AC-3 Rating
9–95 A
Power / Duty
4–45 kW (380/400 V)
Cực
3P
Control Coil
AC/DC 24 V, 48 V, 100–240 V
Khởi động từ 4 cực AC VIOX CJX2s-4P
4-Pole AC-1 / AC-3

CJX2s-4P

Khởi động từ 4 cực AC VIOX CJX2s-4P

AC-3 Rating
9–95 A (Ui 690 V)
Power / Duty
Resistive / 4P switching
Cực
4P (04: 4NO · 08: 2NO+2NC)
Control Coil
AC 50/60 Hz
Khởi động từ AC loại nhỏ VIOX CJX2s-M
Miniature

CJX2s-M

Khởi động từ AC loại nhỏ VIOX CJX2s-M

AC-3 Rating
6–16 A
Power / Duty
2.2–7.5 kW (380/400 V)
Cực
3P / 4P
Control Coil
AC coil, DC coil & pin-type
Contactor AC nhỏ gọn VIOX KCC6-M
Compact OEM

KCC6-M

Contactor AC nhỏ gọn VIOX KCC6-M

AC-3 Rating
9–38 A
Power / Duty
4–18.5 kW (380/400 V)
Cực
2P / 3P
Control Coil
AC 50/60 Hz

Compare all six VIOX AC contactor series

Side-by-side comparison of published IEC 60947-4-1 AC-3 current ratings, motor power, pole options, and coil architectures.

Yếu tố lựa chọn CJX2s CJX2s Dòng điện lớn CJX2s-W CJX2s-4P CJX2s-M KCC6-M
AC-3 current (380/400 V) 9–110 A120–800 A9–95 A9–95 A (Ui 690 V)6–16 A9–38 A
Motor power / duty 4–55 kW (380/400 V)55–450 kW (380/400 V)4–45 kW (380/400 V)Resistive / 4P switching2.2–7.5 kW (380/400 V)4–18.5 kW (380/400 V)
Cực 3P3P3P4P (04: 4NO · 08: 2NO+2NC)3P / 4P2P / 3P
Cuộn dây điều khiển AC 50/60 Hz (24–400 V)AC / DC control coilAC/DC 24 V, 48 V, 100–240 VAC 50/60 HzAC coil, DC coil & pin-typeAC 50/60 Hz
Mounting / housing 35 mm DIN-rail or screwPanel base screw mount35 mm DIN-rail or screw35 mm DIN-rail or screwCompact DIN-rail / PCB pinCompact DIN-rail · IP40
Tiếp điểm phụ 1NO / 1NC / 1NO+1NC2NO + 2NC built-in1NO / 1NC / 1NO+1NCAdd-on front/side blocks1NO or 1NC built-in1NO or 1NC
Datasheet & SKU View CJX2s →View CJX2s High-Current →View CJX2s-W →View CJX2s-4P →View CJX2s-M →View KCC6-M →

Why Standard AC Contactors Fail in Real Panels — And How VIOX Engineers Around It

Field callbacks on motor control panels rarely stem from bench specs. They happen under locked-rotor inrush, sagging grid voltage, and uncoordinated fault energy.

01Contact Weld

Contact Welding & Single-Phasing

Undersized contacts weld under 6×In motor inrush or burn out one phase, causing destructive motor single-phasing.

VIOX EngineeringMatch verified IEC 60947-4-1 AC-3 ratings from 6 A to 800 A across CJX2s and KCC6-M.
02Coil Chatter

Coil Burnout on Unstable Grids

Voltage drops below 85% Us prevent AC armatures from sealing, spiking holding current until coil insulation burns.

VIOX EngineeringChỉ định CJX2s-W electronic coils (AC/DC 24 V, 48 V, 100–240 V) for silent, sag-immune hold.
03EMI Spike

PLC Resets at Coil Turn-Off

Inductive coil de-energization injects high-voltage back-EMF spikes onto control buses, resetting PLCs and pitting relay outputs.

VIOX EngineeringPair coils with RC/varistor suppressors per our suppressor sizing guide.
04Phối hợp

Short-Circuit Let-Through Damage

Uncoordinated upstream breakers let excessive I²t fault energy weld or rupture contactor chambers during bolted faults.

VIOX EngineeringXác minh Type 1 vs Type 2 coordination with matched upstream MPCB hay MCCBs.

IEC 60947-4-1 Utilization Category & Motor Power (kW) Sizing Guide

Unlike circuit breakers sized only by steady-state current, AC contactors must be matched to switching duty (AC-1, AC-3, AC-4), locked-rotor inrush, and coil stability at 380/400 V AC.

IEC 60947-4-1 AC-1, AC-3, and AC-4 utilization and motor kW sizing table for VIOX AC contactors
Duty / Motor Power Band (400 V) IEC Utilization Switching Stress Recommended VIOX Series Key Engineering Check
Small Motors (2.2–7.5 kW · 6–16 A) AC-3 Make 6×In · Break 1×In CJX2s-M Miniature Compact DIN-rail or PCB pin mount; AC/DC coil
OEM Machinery & HVAC (4–18.5 kW · 9–38 A) AC-3 Frequent compressor starts KCC6-M Compact 2P / 3P · IP40 housing for tight OEM panels
Standard Industrial Motors (4–55 kW · 9–110 A) AC-3 Make 6×In · Break 1×In CJX2s Standard Pair with rơ le quá tải hay MPCB
Heavy Industrial Drives (55–450 kW · 120–800 A) AC-3 High arc energy & busbar heat CJX2s Dòng điện lớn Built-in 2NO+2NC aux; verify Type 2 upstream MCCB
Unstable Grids & PLC Cabinets (4–45 kW · 9–95 A) AC-3 / AC-1 Voltage dips & cabinet heat CJX2s-W Electronic Coil AC/DC 24 V, 48 V, 100–240 V; zero coil chatter
Resistive Heating, Lighting & Neutral Switching AC-1 1×In continuous (cos φ ≥ 0.95) CJX2s-4P Four-Pole Select 04 (4NO) or 08 (2NO+2NC); Ui 690 V
Inching, Plugging & Frequent Reversing AC-4 Make 6×In · Break 6×In CJX2s (Derated 1–2 Frames) Add mechanical interlock + RC coil suppressor

How VIOX AC Contactors Compare Across IEC 60947-4-1 Tiers

Objective engineering benchmark across current span, wide-voltage electronic coil availability, pole architecture, and factory-direct B2B supply.

VIOX AC contactor benchmark against global Tier-1 and entry-tier lines
Evaluation Parameter Global Tier-1 Industrial Lines Entry-Tier Commodity Lines VIOX CJX2s / CJX2s-W / KCC6-M
Tiêu Chuẩn Tuân IEC/EN 60947-4-1 Basic AC-3 only IEC/EN 60947-4-1 (Full 6–800 A)
AC-3 Current & Power Span 6–800 A (up to 450 kW) Typically stops at 95 A 6–800 A (up to 450 kW at 400 V)
Wide-Voltage Electronic Coils Premium price tier Fixed AC coils only CJX2s-W: AC/DC 24 V, 48 V, 100–240 V
Specialty Configurations Mini, 3P, 4P, compact Standard 3P only Mini (M), 3P, 4P (04/08), Compact (KCC6-M)
OEM & Distributor Supply Fixed brand; long high-amp lead times Inconsistent silver-alloy & coil QA Factory-direct pricing + private-label OEM

Direct Factory Contactor Line

VIOX supplies all six IEC 60947-4-1 AC contactor platforms (6–800 A) directly from factory production—verified for coil pick-up and drop-out margins, silver-alloy contact endurance, dielectric strength, and private-label OEM laser marking across distributor and panel-builder programs.

AC Contactor Quotation Variables — What Moves Unit Pricing

Key technical and commercial drivers behind factory-direct AC contactor quotes. See also how to read a contactor model number.

Quotation variables for VIOX AC contactors
Quotation Variable Standard Spec Range Pricing & Lead-Time Impact
Frame Size & AC-3 Rating 6–16 A (Mini) · 9–110 A (Std) · 120–800 A (High-Current) Drives silver-alloy contact mass, arc chute size, and copper busbar weight
Coil Technology Standard AC 24–400 V vs CJX2s-W Electronic AC/DC 24–240 V Wide-voltage electronic coils reduce total SKU count across export markets
Pole & Auxiliary Count 2P / 3P / 4P (04 or 08) + built-in 1NO/1NC or 2NO+2NC Standard 3P 230 V coils carry fastest factory stock dispatch
Branding & Consolidation VIOX stock or OEM laser marking + custom inner boxes Consolidate with Công, RCBO, Và MCCBs in one shipment

Sourcing Mixed-Amperage or OEM Private-Label AC Contactors?

Send your contactor current list, coil voltages, and pole counts—our factory team will return matched pricing, lead times, and evaluation samples.

Request AC Contactor Quote →

AC Contactor Selection & Procurement Questions

Direct answers on AC-1/AC-3/AC-4 sizing, CJX2s-W wide-voltage electronic coils, Type 1/Type 2 coordination, and OEM factory supply.

Công năng sử dụng What is the difference between AC-1, AC-3, and AC-4 ratings when sizing an AC contactor?

Under IEC 60947-4-1, AC-1 applies to non-inductive or slightly inductive resistive loads (heaters, lighting, distribution feeders) where switching current equals rated current. AC-3 governs standard squirrel-cage motor starting (6×In inrush) and switching off while running.

AC-4 covers severe inching, plugging, and frequent reversing where the contactor breaks full locked-rotor current (6×In). Always size motor contactors by AC-3 kW/A rating—and derate substantially for AC-4 duty to prevent contact welding.

Coil Selection When should I choose a CJX2s-W electronic-coil contactor instead of a standard laminated AC coil?

Specify VIOX CJX2s-W (9–95 A, AC/DC 24 V, 48 V, or 100–240 V wide-voltage electronic coils) on sites with unstable supply voltage, generator-backed panels, or high-density PLC cabinets where low coil holding power and hum-free operation matter.

Electronic coils eliminate coil chattering during voltage dips and allow one universal AC/DC coil SKU to replace multiple fixed-voltage inventory items across 50/60 Hz markets.

Series Comparison How do CJX2s, CJX2s High-Current, CJX2s-4P, CJX2s-M, and KCC6-M differ?

CJX2s (9–110 A, 4–55 kW) is the core 3P motor contactor; CJX2s High-Current scales to 120–800 A (55–450 kW) with built-in 2NO+2NC auxiliaries. CJX2s-4P (9–95 A, Ui 690 V) provides 4NO (04) or 2NO+2NC (08) main poles for resistive and neutral switching.

CJX2s-M (6–16 A, 3P/4P) serves tight DIN-rail or PCB/pin-type layouts, while KCC6-M (9–38 A, 2P/3P, IP40 housing) targets compact HVAC and OEM machinery panels.

Phối hợp How do Type 1 and Type 2 short-circuit coordination work for AC contactors?

Under IEC 60947-4-1, Type 1 coordination permits contactor damage during a short circuit provided there is no external hazard, requiring replacement before restart. Type 2 coordination ensures the contactor remains operable after fault clearance with only minor, easily separable contact tacking.

Achieving Type 2 coordination depends on matching the VIOX AC contactor with a properly rated upstream MPCB, MCCB, or gG/aM fuse verified for the panel prospective short-circuit current.

Coil Protection Why should PLC-driven AC contactors include RC or varistor surge suppressors?

When an inductive AC contactor coil is de-energized, the collapsing magnetic field generates high-voltage switching transients that can reset nearby PLCs, trigger false sensor readings, or erode relay output contacts.

Mounting a dedicated RC or varistor surge suppressor across the coil terminals clamps these transients at the source and extends control-circuit service life.

OEM / B2B Supply Can VIOX supply OEM or private-label AC contactors with mixed coil voltages?

Yes. VIOX supports panel builders, OEM machinery manufacturers, and electrical wholesalers with factory-direct CJX2s and KCC6-M supply across mixed amperage and coil-voltage schedules, laser-marked private labeling, and IEC 60947-4-1 documentation.

Send your motor kW/A schedule, coil voltage, and pole configuration for matched factory pricing and lead times.

Bạn cần khởi động từ AC phù hợp?
Hãy cùng chúng tôi xác nhận điều đó.

Send your AC-3 motor kW/A rating, coil voltage, pole configuration, quantity, and target market. VIOX engineers will match the right CJX2s or KCC6-M series.

Request AC Contactor Quote