The VIOX VRL22B is a Type B residual current circuit breaker with overcurrent protection for AC 50/60 Hz installations. It combines residual-current, overload and short-circuit protection and detects sinusoidal AC, pulsating DC and smooth DC residual currents. Type B covers residual-current frequencies up to 1 kHz, while the Type B+ variant extends detection up to 20 kHz. The 2P and 4P configurations are intended for applications incorporating frequency converters, photovoltaic and UPS systems, medical equipment, elevator controllers, trace-heating systems and variable-speed machinery.
Đặc trưng
- Type B detection of sinusoidal AC, pulsating DC and smooth DC residual currents.
- Type B frequency range up to 1 kHz.
- Type B+ frequency range up to 20 kHz.
- B, C and D overcurrent tripping curves.
- Instantaneous, K short-time-delayed and S selective versions.
- 6 kA or 10 kA rated conditional short-circuit current.
- Electrical isolation through a contact gap greater than 4 mm.
Mô hình
| Người mẫu | Cực | Maximum Rated Current | Điện áp định mức |
|---|---|---|---|
| VRL22B | 2P | 63 A | 230/240 V AC |
| VRL22-40B | 4 P | 40 A | 400/415 V AC |
| VRL22-63B | 4 P | 63 A | 400/415 V AC |
| Variant | Phát hiện dòng điện dư | Dải tần số | Additional Characteristic |
|---|---|---|---|
| Loại B | Sinusoidal AC, pulsating DC and smooth DC residual currents | Lên đến 1 kHz | Universal current-sensitive RCBO |
| Loại B+ | Full Type B residual-current detection capability | Lên đến 20 kHz | Additional tripping values below 420 mA as specified by VDE 0664-400 |
Thông số kỹ thuật
Electrical Data
| Tham số | Đặc điểm kỹ thuật |
|---|---|
| Bình Hiện Tại | 6, 10, 13, 15, 16, 20, 25, 32, 40, 50, 63 A |
| Điện áp định mức | 2P: 230/240 V AC; 4P: 400/415 V AC |
| Tần số định mức | 50/60 Hz |
| Electronic Operating Voltage | 50-264 V AC |
| Test-Circuit Voltage Range | 2P: 184-264 V AC; 4P: 184-440 V AC |
| Điện áp cách điện định mức | 500 V |
| Điện áp chịu xung định mức | 4 kV, 1.2/50 μs |
Protection Data
| Tham số | Đặc điểm kỹ thuật |
|---|---|
| Residual-Current Variants | Type B; Type B+ |
| Rated Residual Operating Current | 30, 100, 300, 500 mA |
| Tripping Curves | B: 3-5 In; C: 5-10 In; D: 10-20 In |
| Rated Conditional Short-Circuit Current | 6 kA or 10 kA; energy-limiting class 3 for B and C curves |
| Rated Making and Breaking Capacity | 3,000 A |
| Peak Withstand Current | 3 kA, 8/20 μs; 5 kA, 8/20 μs for Type S |
Installation and Environmental Data
| Tham số | Đặc điểm kỹ thuật |
|---|---|
| Mức độ bảo vệ | IP20 |
| Loại Đầu Cuối | Open-mounted / lift terminals |
| Công suất thiết bị đầu cuối | 1-25 mm² |
| Terminal Tightening Torque | 2-2.5 N·m |
| Busbar Thickness | 0.8-2 mm |
| Cách ly điện | > 4 mm contact gap |
| Nhiệt độ hoạt động | -25 °C to +55 °C |
| Storage and Transport Temperature | -40 °C to +70 °C |
Mechanical Data
| Tham số | Đặc điểm kỹ thuật |
|---|---|
| Độ bền điện | ≥ 5,000 operating cycles |
| Độ bền cơ học | ≥ 5,000 operating cycles |
Tiêu chuẩn
| Variant | Các tiêu chuẩn áp dụng |
|---|---|
| Loại B | IEC/EN 62423; IEC/EN 61009-1; OVE E 8601 |
| Loại B+ | IEC/EN 62423; IEC/EN 61009-1; OVE E 8601; VDE 0664-400 |
Hướng dẫn lựa chọn
| Code Element | Ý nghĩa | Available Values |
|---|---|---|
| V | VIOX enterprise identification | V |
| RL | RCBO product family | RL |
| 22 | Design series | 22 |
| B | Loại dòng dư | B |
| Đường cong đặc tính | Đường cong tác động quá dòng | B, C or D |
| Hiện hành | Dòng điện định mức | 6-63 A |
| Nhạy cảm | Dòng điện dư định mức khi vận hành | 30-500 mA |
| Cực | Số cực | 2P or 4P |
Catalog configuration example: V-RL-22-B-C-32A-30mA-2P
Type B or B+
Select Type B for residual-current frequencies up to 1 kHz or Type B+ where the cataloged frequency range up to 20 kHz is required.
Operating Variant
Confirm whether instantaneous, K short-time-delayed or S selective operation is required and select the corresponding residual-current rating.
Bình Hiện Tại
Select from 6 A to 63 A, observing the 40 A limit of the VRL22-40B model.
Poles and Voltage
Select 2P for 230/240 V AC or 4P for 400/415 V AC circuits.
Đường cong chuyến đi
| Kiểm tra dòng điện | Specified Time | Quả | Đường cong đặc tính |
|---|---|---|---|
| 1.13 Trong | t ≥ 1 h | Non-tripping | B, C |
| 1,45 Trong | t < 1 h | vấp ngã | B, C |
| 2,55 Trong | 1 s < t < 60 s | vấp ngã | B, C |
| 3 In | t ≥ 0.1 s | Non-tripping | B |
| 5 In | t < 0.1 s | vấp ngã | B |
| 5 In | t ≥ 0.1 s | Non-tripping | C |
| 10 In | t < 0.1 s | vấp ngã | C |
| At IΔn | At 2 IΔn | At 5 IΔn | At IΔt |
|---|---|---|---|
| 0.10 s | 0.05 s | 0.04 s | 0.04 s |
Kích thước
Ứng dụng
- Frequency converters and variable-speed machinery.
- Photovoltaic and UPS systems.
- Medical equipment and elevator controllers.
- Trace-heating systems.
Cài đặt
- Use open-mounted or lift terminals with conductors from 1 mm² to 25 mm².
- Tighten terminals to 2-2.5 N·m.
- Use busbars with a thickness of 0.8-2 mm when applicable.
- Match the 2P or 4P configuration to the specified circuit voltage.
- Confirm the required Type B or Type B+ residual-current response before selection.
Câu hỏi thường gặp
What residual currents does the VRL22B detect?
Type B detects sinusoidal AC, pulsating DC and smooth DC residual currents.
What is the difference between Type B and Type B+?
Type B covers residual-current frequencies up to 1 kHz. Type B+ extends the range to 20 kHz and provides additional tripping values below 420 mA as specified by VDE 0664-400.
Which rated currents are available?
The listed rated-current options are 6, 10, 13, 15, 16, 20, 25, 32, 40, 50 and 63 A.
Which pole configurations are available?
The VRL22B family is available in 2P and 4P configurations.
Which applications are listed for this Type B RCBO?
The catalog identifies frequency converters, photovoltaic and UPS systems, medical equipment, elevator controllers, trace heating and variable-speed machinery.