Máy cắt điện chống dòng điện dư VKL11

The VIOX VKL11 residual current circuit breaker provides earth-leakage protection for AC 50/60 Hz installations. It is available in Type AC, Type A and high-immunity Type ASi versions, with 16-100 A ratings, 10-300 mA sensitivities, and 2P or 4P configurations. Designed for 35 mm DIN-rail mounting, it includes voltage-independent magnetic operation, a fault-current indicator and top or bottom power entry.

Bình Hiện Tại
16-100 A
Dòng rò (Residual Current)
10 mA (16-40 A); 30, 100, 300 mA
Cấu hình cực
2P, 4P
Loại RCCB
AC, A, ASi

Tổng quan

The VKL11 is a residual current circuit breaker for residual-current protection in AC 50/60 Hz electrical installations. It disconnects the circuit when earth leakage is detected and is available in Type AC, Type A and high-immunity Type ASi versions. The range covers rated currents from 16 A to 100 A, residual operating currents from 10 mA to 300 mA, and 2P or 4P configurations rated at 240 V AC or 415 V AC. Designed for residential, commercial and industrial distribution systems, it mounts on a 35 mm DIN rail and is intended for use with suitable overload and short-circuit protection.

Đặc trưng

  • Compliant with IEC/EN 61008-1.
  • Type AC, Type A and high-immunity Type ASi versions.
  • Voltage-independent magnetic operation.
  • Integrated fault-current indicator.
  • Rated-current options from 16 A to 100 A.
  • Top or bottom power entry.

Mô hình

Loại Detectable residual current Đặc tính thời gian Recommended applications
Loại AC Dòng điện dư xoay chiều hình sin Tức thời Conventional AC circuits and resistive loads
Loại A Sinusoidal AC and pulsating DC residual currents Tức thời Residential, commercial and electronic equipment circuits
Loại ASi Type A characteristics with enhanced immunity to nuisance tripping Trễ thời gian ngắn Circuits affected by harmonics, transient surges or electronic equipment

Thông số kỹ thuật

Electrical Data

Tham số Đặc điểm kỹ thuật
Dòng điện định mức 16, 25, 32, 40, 63, 80, 100 A
Dòng điện dư định mức khi vận hành 10 mA (16-40 A); 30, 100, 300 mA
Bình áp 240 V AC (2P); 415 V AC (4P)
Tần số định mức 50/60 Hz
Khả năng đóng và cắt dòng rò định mức. 500 A (16-40 A); 630 A (63 A); 800 A (80 A); 1,000 A (100 A)
Dòng điện ngắn mạch có điều kiện định mức 6/10 kA
Điện áp cách điện định mức 500 V
Điện áp chịu xung định mức 6 kV
Dielectric test voltage 2.5 kV for 1 minute

Protection Data

Tham số Đặc điểm kỹ thuật
Loại dòng rò AC, A, ASi
Tripping characteristic Instantaneous; short-time delayed for ASi
Số cực 2P, 4P
Fault-current indicator Yes
Mức độ bảo vệ IP20

Mechanical Data

Tham số Đặc điểm kỹ thuật
Cuộc sống điện ≥2,000 operations
Cuộc sống cơ học ≥2,000 operations

Installation Data

Tham số Đặc điểm kỹ thuật
Lắp ráp 35 mm DIN rail, EN 60715
Terminal connection Cable or pin-type busbar
Công suất thiết bị đầu cuối Up to 35 mm²
Mô-men xoắn siết chặt 2,5 N·m
Power entry Trên hoặc dưới

Environmental and Standards Data

Tham số Đặc điểm kỹ thuật
Nhiệt độ hoạt động -25°C đến +55°C
Nhiệt độ lưu trữ -40°C đến +70°C
Ô nhiễm độ 2
Compliant standard IEC/EN 61008-1

Hướng dẫn lựa chọn

Code position Ý nghĩa Catalog value or options
V VIOX enterprise identification V
KL RCCB product family code KL
11 Design serial number 11
AC / A / ASi Loại dòng rò AC, A or ASi
Rated-current code Dòng điện định mức 16, 25, 32, 40, 63, 80 or 100 A
Residual-current code Dòng điện dư định mức khi vận hành 10, 30, 100 or 300 mA
2P / 4P Số cực 2P or 4P

Residual Current Type

Select Type AC for sinusoidal AC residual current, Type A for sinusoidal AC and pulsating DC residual currents, or Type ASi when enhanced immunity and short-time-delayed operation are required.

Bình Hiện Tại

Choose one of the listed ratings from 16 A to 100 A to match the circuit rating.

Nhạy cảm

Select 10, 30, 100 or 300 mA according to the required protection application. The 10 mA option is listed for 16-40 A ratings.

Poles and Voltage

Select 2P for 240 V AC or 4P for 415 V AC installations.

Kích thước

VKL11 Type A, Type AC and Type ASi RCCB dimensional drawing
VKL11 2P and 4P RCCB dimensional drawing.

Ứng dụng

  • 10 mA sensitivity for sensitive equipment and locations requiring enhanced personal protection.
  • 30 mA sensitivity for additional protection against electric shock.
  • 100 mA sensitivity for protection against indirect contact.
  • 300 mA sensitivity for protection against insulation-fault fire risks.

Cài đặt

  • Mount the selected RCCB on a 35 mm DIN rail in accordance with EN 60715.
  • Use cable or a pin-type busbar within the listed terminal capacity of up to 35 mm².
  • Apply the listed terminal tightening torque of 2.5 N·m.
  • Power entry may be made from the top or bottom.
  • Use the RCCB together with suitable overload and short-circuit protection.

Câu hỏi thường gặp

Which residual current types are available for the VKL11?

The VKL11 is available in Type AC, Type A and Type ASi versions.

Which rated currents and sensitivities are offered?

Rated currents are 16, 25, 32, 40, 63, 80 and 100 A. Residual operating-current options are 10 mA for 16-40 A ratings and 30, 100 or 300 mA.

Which voltage applies to each pole configuration?

The 2P configuration is rated at 240 V AC, while the 4P configuration is rated at 415 V AC.

Does the VKL11 provide overload and short-circuit protection?

The catalog specifies that the VKL11 is intended for use together with suitable overload and short-circuit protection.

How can the VKL11 terminals be connected?

The terminals accept cable or a pin-type busbar, with a listed capacity of up to 35 mm² and a tightening torque of 2.5 N·m.

Which standard is listed for the VKL11?

The catalog lists IEC/EN 61008-1 as the compliant standard.