VIOX VM6EY Series Electronic LCD MCCB with 0.5-Class Metering (250A–1250A)

VIOX VM6EY Series Electronic LCD MCCB (250 A–1250 A, 3P/4P, AC 400 V, Class B Icw 10–20 kA/1s, up to 85 kA Icu) integrates a real-time 3-phase voltage/current LCD display, 0.5-class high-precision metering, four-remote control, and overvoltage, undervoltage, and phase-loss protection.

Frame Range
250–1250 A (5 Frames)
LCD & Metering
Real-Time 3P V/I · 0.5-Class
Class B Icw
10–20 kA/1s · Up to 85 kA Icu
Smart Protection
4-Remote · OV / UV / Phase Loss

Overview

The VIOX VM6EY Series combines a Class B electronic molded case circuit breaker with an integrated backlit LCD display and 0.5-class revenue-grade electrical metering. Covering 5 frames from 250 A to 1250 A (0.4–1.0×In adjustable, 3P/4P, AC 400 V, Ui 1000 V, Uimp 8 kV), VM6EY eliminates separate panel ammeters and voltmeters—delivering real-time three-phase voltage/current monitoring, four-remote telemetry/control, and integrated overvoltage, undervoltage, and phase-loss protection up to 85 kA Icu / 65 kA Ics.

Features

  • Front LCD screen displays real-time three-phase voltages, load currents, and trip diagnostics.
  • 0.5-class high-precision electrical measurement eliminates separate panel metering instruments.
  • Built-in four-remote (telemetry, tele-signaling, tele-control, tele-adjustment) plus overvoltage, undervoltage, and phase-loss protection.
  • Class B selectivity: Icw 10 kA/1s (400–630 A) and 20 kA/1s (800–1250 A), up to 85 kA Icu / 65 kA Ics at AC 400 V.
  • 0.4–1.0×In wide electronic current adjustment across 5 frames (250, 400, 630, 800, and 1250 A).
  • Optional grounding protection (G), overload alarm without trip (III), and 40 K / 50 K / 60 K low-temperature-rise builds.

Models

Frame SeriesAdjustable In (0.4–1.0×In)Breaking TiersIcw (1s)Max Icu / Ics (400 V AC)
VM6EY-250125 A (50–125 A) · 250 A (100–250 A)M, H—65 kA / 65 kA
VM6EY-400400 A (160–400 A)M, H10 kA/1s70 kA / 70 kA
VM6EY-630630 A (252–630 A)M, H10 kA/1s70 kA / 70 kA
VM6EY-800630 A (252–630 A) · 800 A (320–800 A)M, H20 kA/1s85 kA / 65 kA
VM6EY-12501000 A (400–1000 A) · 1250 A (500–1250 A)M, H20 kA/1s85 kA / 65 kA

Specifications

Electrical & Breaking Capacity (AC 400 V)

Frame & TiersIcs (400 V)Icu (400 V)Icw (1s)Category
VM6EY-250 M / H35 / 65 kA50 / 65 kA—Class B
VM6EY-400 M / H50 / 70 kA50 / 70 kA10 kA/1sClass B
VM6EY-630 M / H50 / 70 kA50 / 70 kA10 kA/1sClass B
VM6EY-800 M / H50 / 65 kA50 / 85 kA20 kA/1sClass B
VM6EY-1250 M / H50 / 65 kA50 / 85 kA20 kA/1sClass B

Outline Dimensions (mm)

FramePolesWidth W (mm)Length L (mm)Height Cover / Handle (mm)
VM6EY-2503P / 4P105 / 14016588 / 116
VM6EY-4003P / 4P140 / 184257103 / 152
VM6EY-6303P / 4P210 / 280275.5103 / 152
VM6EY-8003P / 4P210 / 280275.5103 / 152
VM6EY-12503P / 4P210 / 280275.5103 / 152

External Accessories Compatibility

AccessorySupported Frames & Poles
Electric Motor Operation3P, 4P
Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3)3P, 4P
Extension Copper Bar (P)3P, 4P
Mechanical Interlocking3P, 4P (up to 800 A)
Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H)3P, 4P (up to 800 A)
Draw-out Back-Panel (DR)400 / 630 / 800 A (3P only)

Selection Guide

Code PositionMeaningCatalog Value or Options
VM6EYSeriesElectronic LCD molded case circuit breaker with 0.5-class metering
250–1250Frame current250, 400, 630, 800, 1250 A
M / HBreaking tierM (Moderate, conventional) or H (High breaking up to 85 kA)
3 / 4Poles3P or 4P (Neutral Types A, B, C, D)
00–78Internal accessory code00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V)

1. Eliminate Panel Meters

Use VM6EY’s built-in 0.5-class LCD display to save door cutout space and external CT wiring.

2. Protect Voltage Quality

Enable built-in overvoltage, undervoltage, and phase-loss protection for sensitive industrial plants.

3. Enable Four-Remote

Pair with DC3/DC6 electric operators for full remote SCADA monitoring and breaker control.

4. Match Class B Icw

Use 10–20 kA/1s short-time delay for coordinated main-switchboard distribution.

Installation

  • Verify door cutout alignment if viewing the front LCD display through a panel door window.
  • Confirm external power supply for four-remote communication modules when operating in the open state.
  • Note VM6EY-630 uses the 210/280 × 275.5 mm frame outline for enhanced thermal margin.
  • Explore VM6ELY if integrated 4P earth-leakage protection is also required.

FAQ

What does the LCD screen on VM6EY display?

The front LCD provides real-time three-phase line/phase voltage, per-phase load current, protection settings, and fault-trip records with 0.5-class measurement accuracy.

What extra protections does VM6EY include beyond standard LSIG?

In addition to electronic overcurrent protection, VM6EY integrates overvoltage, undervoltage, and phase-loss protection plus optional ground fault (Code G).

What frame sizes does VM6EY cover?

VM6EY covers five frames: 250 A, 400 A, 630 A, 800 A, and 1250 A, all 0.4–1.0×In adjustable in 3P and 4P.

Can VM6EY perform remote opening and closing?

Yes. VM6EY supports four-remote control when paired with a P1 (DC3) or P2 (DC6) electric operating mechanism.

What is the short-time withstand current (Icw) of VM6EY?

VM6EY is a Class B MCCB rated at 10 kA/1s on 400–630 A frames and 20 kA/1s on 800–1250 A frames.

Are plug-in and draw-out kits compatible with VM6EY?

Yes. Plug-in front/back bases are supported from 250 A to 800 A (3P/4P), and draw-out back-panel bases are supported on 400, 630, and 800 A (3P).

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Need a Product Quote?
Let’s Build It Together.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Request a Quote