VIOX VM6EY Series Electronic LCD MCCB with 0.5-Class Metering (250A–1250A)

VIOX VM6EY Series Electronic LCD MCCB (250 A–1250 A, 3P/4P, AC 400 V, Class B Icw 10–20 kA/1s, up to 85 kA Icu) integrates a real-time 3-phase voltage/current LCD display, 0.5-class high-precision metering, four-remote control, and overvoltage, undervoltage, and phase-loss protection.

Frame Range
250–1250 A (5 Frames)
LCD & Metering
Real-Time 3P V/I · 0.5-Class
Class B Icw
10–20 kA/1s · Up to 85 kA Icu
Smart Protection
4-Remote · OV / UV / Phase Loss

Vue d'ensemble

The VIOX VM6EY Series combines a Class B electronic molded case circuit breaker with an integrated backlit LCD display and 0.5-class revenue-grade electrical metering. Covering 5 frames from 250 A to 1250 A (0.4–1.0×In adjustable, 3P/4P, AC 400 V, Ui 1000 V, Uimp 8 kV), VM6EY eliminates separate panel ammeters and voltmeters—delivering real-time three-phase voltage/current monitoring, four-remote telemetry/control, and integrated overvoltage, undervoltage, and phase-loss protection up to 85 kA Icu / 65 kA Ics.

Caractéristiques

  • Front LCD screen displays real-time three-phase voltages, load currents, and trip diagnostics.
  • 0.5-class high-precision electrical measurement eliminates separate panel metering instruments.
  • Built-in four-remote (telemetry, tele-signaling, tele-control, tele-adjustment) plus overvoltage, undervoltage, and phase-loss protection.
  • Class B selectivity: Icw 10 kA/1s (400–630 A) and 20 kA/1s (800–1250 A), up to 85 kA Icu / 65 kA Ics at AC 400 V.
  • 0.4–1.0×In wide electronic current adjustment across 5 frames (250, 400, 630, 800, and 1250 A).
  • Optional grounding protection (G), overload alarm without trip (III), and 40 K / 50 K / 60 K low-temperature-rise builds.

Modèles

Frame SeriesAdjustable In (0.4–1.0×In)Breaking TiersIcw (1s)Max Icu / Ics (400 V AC)
VM6EY-250125 A (50–125 A) · 250 A (100–250 A)M, H—65 kA / 65 kA
VM6EY-400400 A (160–400 A)M, H10 kA/1s70 kA / 70 kA
VM6EY-630630 A (252–630 A)M, H10 kA/1s70 kA / 70 kA
VM6EY-800630 A (252–630 A) · 800 A (320–800 A)M, H20 kA/1s85 kA / 65 kA
VM6EY-12501000 A (400–1000 A) · 1250 A (500–1250 A)M, H20 kA/1s85 kA / 65 kA

Spécifications

Electrical & Breaking Capacity (AC 400 V)

Frame & TiersIcs (400 V)Icu (400 V)Icw (1s)Catégorie
VM6EY-250 M / H35 / 65 kA50 / 65 kA—Classe B
VM6EY-400 M / H50 / 70 kA50 / 70 kA10 kA/1sClasse B
VM6EY-630 M / H50 / 70 kA50 / 70 kA10 kA/1sClasse B
VM6EY-800 M / H50 / 65 kA50 / 85 kA20 kA/1sClasse B
VM6EY-1250 M / H50 / 65 kA50 / 85 kA20 kA/1sClasse B

Outline Dimensions (mm)

CadrePôlesWidth W (mm)Length L (mm)Height Cover / Handle (mm)
VM6EY-2503P / 4P105 / 14016588 / 116
VM6EY-4003P / 4P140 / 184257103 / 152
VM6EY-6303P / 4P210 / 280275.5103 / 152
VM6EY-8003P / 4P210 / 280275.5103 / 152
VM6EY-12503P / 4P210 / 280275.5103 / 152

External Accessories Compatibility

AccessoireSupported Frames & Poles
Electric Motor Operation3P, 4P
Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3)3P, 4P
Extension Copper Bar (P)3P, 4P
Verrouillage mécanique3P, 4P (up to 800 A)
Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H)3P, 4P (up to 800 A)
Draw-out Back-Panel (DR)400 / 630 / 800 A (3P only)

Guide de sélection

Position du codeSignificationCatalog Value or Options
VM6EYSérieElectronic LCD molded case circuit breaker with 0.5-class metering
250–1250Courant de châssis250, 400, 630, 800, 1250 A
M / HBreaking tierM (Moderate, conventional) or H (High breaking up to 85 kA)
3 / 4Pôles3P or 4P (Neutral Types A, B, C, D)
00–78Internal accessory code00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V)

1. Eliminate Panel Meters

Use VM6EY’s built-in 0.5-class LCD display to save door cutout space and external CT wiring.

2. Protect Voltage Quality

Enable built-in overvoltage, undervoltage, and phase-loss protection for sensitive industrial plants.

3. Enable Four-Remote

Pair with DC3/DC6 electric operators for full remote SCADA monitoring and breaker control.

4. Match Class B Icw

Use 10–20 kA/1s short-time delay for coordinated main-switchboard distribution.

Installation

  • Verify door cutout alignment if viewing the front LCD display through a panel door window.
  • Confirm external power supply for four-remote communication modules when operating in the open state.
  • Note VM6EY-630 uses the 210/280 × 275.5 mm frame outline for enhanced thermal margin.
  • Explorer VM6ELY if integrated 4P earth-leakage protection is also required.

FAQ

What does the LCD screen on VM6EY display?

The front LCD provides real-time three-phase line/phase voltage, per-phase load current, protection settings, and fault-trip records with 0.5-class measurement accuracy.

What extra protections does VM6EY include beyond standard LSIG?

In addition to electronic overcurrent protection, VM6EY integrates overvoltage, undervoltage, and phase-loss protection plus optional ground fault (Code G).

What frame sizes does VM6EY cover?

VM6EY covers five frames: 250 A, 400 A, 630 A, 800 A, and 1250 A, all 0.4–1.0×In adjustable in 3P and 4P.

Can VM6EY perform remote opening and closing?

Yes. VM6EY supports four-remote control when paired with a P1 (DC3) or P2 (DC6) electric operating mechanism.

What is the short-time withstand current (Icw) of VM6EY?

VM6EY is a Class B MCCB rated at 10 kA/1s on 400–630 A frames and 20 kA/1s on 800–1250 A frames.

Are plug-in and draw-out kits compatible with VM6EY?

Yes. Plug-in front/back bases are supported from 250 A to 800 A (3P/4P), and draw-out back-panel bases are supported on 400, 630, and 800 A (3P).

2026 Technical Catalog · Online PDF
VIOX Full 18-Series MCCB & Intelligent Breaker Catalog
Open the complete 18-series catalog online for frame dimensions, time-current trip curves, wiring schematics, and factory order codes (PDF · 26.7 MB).
Open Full Catalog PDF ↗

Besoin d'un devis produit ?
Construisons-le ensemble.

Envoyez-nous le modèle du produit, les caractéristiques techniques, la quantité et les exigences OEM. Notre équipe examinera votre demande et vous répondra dans un délai d'un jour ouvré.

Demander un Devis