Visão geral
The VIOX VM6EY Series combines a Class B electronic molded case circuit breaker with an integrated backlit LCD display and 0.5-class revenue-grade electrical metering. Covering 5 frames from 250 A to 1250 A (0.4–1.0×In adjustable, 3P/4P, AC 400 V, Ui 1000 V, Uimp 8 kV), VM6EY eliminates separate panel ammeters and voltmeters—delivering real-time three-phase voltage/current monitoring, four-remote telemetry/control, and integrated overvoltage, undervoltage, and phase-loss protection up to 85 kA Icu / 65 kA Ics.
Caraterísticas
- Front LCD screen displays real-time three-phase voltages, load currents, and trip diagnostics.
- 0.5-class high-precision electrical measurement eliminates separate panel metering instruments.
- Built-in four-remote (telemetry, tele-signaling, tele-control, tele-adjustment) plus overvoltage, undervoltage, and phase-loss protection.
- Class B selectivity: Icw 10 kA/1s (400–630 A) and 20 kA/1s (800–1250 A), up to 85 kA Icu / 65 kA Ics at AC 400 V.
- 0.4–1.0×In wide electronic current adjustment across 5 frames (250, 400, 630, 800, and 1250 A).
- Optional grounding protection (G), overload alarm without trip (III), and 40 K / 50 K / 60 K low-temperature-rise builds.
Modelos
| Frame Series | Adjustable In (0.4–1.0×In) | Breaking Tiers | Icw (1s) | Max Icu / Ics (400 V AC) |
|---|---|---|---|---|
| VM6EY-250 | 125 A (50–125 A) · 250 A (100–250 A) | M, H | — | 65 kA / 65 kA |
| VM6EY-400 | 400 A (160–400 A) | M, H | 10 kA/1s | 70 kA / 70 kA |
| VM6EY-630 | 630 A (252–630 A) | M, H | 10 kA/1s | 70 kA / 70 kA |
| VM6EY-800 | 630 A (252–630 A) · 800 A (320–800 A) | M, H | 20 kA/1s | 85 kA / 65 kA |
| VM6EY-1250 | 1000 A (400–1000 A) · 1250 A (500–1250 A) | M, H | 20 kA/1s | 85 kA / 65 kA |
Especificações
Electrical & Breaking Capacity (AC 400 V)
| Frame & Tiers | Ics (400 V) | Icu (400 V) | Icw (1s) | Categoria |
|---|---|---|---|---|
| VM6EY-250 M / H | 35 / 65 kA | 50 / 65 kA | — | Classe B |
| VM6EY-400 M / H | 50 / 70 kA | 50 / 70 kA | 10 kA/1s | Classe B |
| VM6EY-630 M / H | 50 / 70 kA | 50 / 70 kA | 10 kA/1s | Classe B |
| VM6EY-800 M / H | 50 / 65 kA | 50 / 85 kA | 20 kA/1s | Classe B |
| VM6EY-1250 M / H | 50 / 65 kA | 50 / 85 kA | 20 kA/1s | Classe B |
Outline Dimensions (mm)
| Quadro | Pólos | Width W (mm) | Length L (mm) | Height Cover / Handle (mm) |
|---|---|---|---|---|
| VM6EY-250 | 3P / 4P | 105 / 140 | 165 | 88 / 116 |
| VM6EY-400 | 3P / 4P | 140 / 184 | 257 | 103 / 152 |
| VM6EY-630 | 3P / 4P | 210 / 280 | 275.5 | 103 / 152 |
| VM6EY-800 | 3P / 4P | 210 / 280 | 275.5 | 103 / 152 |
| VM6EY-1250 | 3P / 4P | 210 / 280 | 275.5 | 103 / 152 |
External Accessories Compatibility
| Acessório | Supported Frames & Poles |
|---|---|
| Electric Motor Operation | 3P, 4P |
| Manual Rotary Handle (ZY1/ZF1/ZY2/ZF2/Z3) | 3P, 4P |
| Extension Copper Bar (P) | 3P, 4P |
| Intertravamento mecânico | 3P, 4P (up to 800 A) |
| Plug-in Front / Back Panel (Z2Q/Z2H/Z3Q/Z3H) | 3P, 4P (up to 800 A) |
| Draw-out Back-Panel (DR) | 400 / 630 / 800 A (3P only) |
Guia de seleção
| Posição do código | Significado | Catalog Value or Options |
|---|---|---|
| VM6EY | Série | Electronic LCD molded case circuit breaker with 0.5-class metering |
| 250–1250 | Corrente de quadro | 250, 400, 630, 800, 1250 A |
| M / H | Breaking tier | M (Moderate, conventional) or H (High breaking up to 85 kA) |
| 3 / 4 | Pólos | 3P or 4P (Neutral Types A, B, C, D) |
| 00–78 | Internal accessory code | 00 None · 08 Alarm · 10 Shunt · 18 Shunt+Alarm · 20/27 Aux · 28/29 Aux+Alarm · 30 UVT · 38 UVT+Alarm · 40/41/48 Shunt+Aux · 50 Shunt+UVT · 60–69 Multi-Aux · 70–78 UVT+Aux (DC 24/110/220 V, AC 230/400 V) |
1. Eliminate Panel Meters
Use VM6EY’s built-in 0.5-class LCD display to save door cutout space and external CT wiring.
2. Protect Voltage Quality
Enable built-in overvoltage, undervoltage, and phase-loss protection for sensitive industrial plants.
3. Enable Four-Remote
Pair with DC3/DC6 electric operators for full remote SCADA monitoring and breaker control.
4. Match Class B Icw
Use 10–20 kA/1s short-time delay for coordinated main-switchboard distribution.
Instalação
- Verify door cutout alignment if viewing the front LCD display through a panel door window.
- Confirm external power supply for four-remote communication modules when operating in the open state.
- Note VM6EY-630 uses the 210/280 × 275.5 mm frame outline for enhanced thermal margin.
- Explorar VM6ELY if integrated 4P earth-leakage protection is also required.
FAQ
What does the LCD screen on VM6EY display?
The front LCD provides real-time three-phase line/phase voltage, per-phase load current, protection settings, and fault-trip records with 0.5-class measurement accuracy.
What extra protections does VM6EY include beyond standard LSIG?
In addition to electronic overcurrent protection, VM6EY integrates overvoltage, undervoltage, and phase-loss protection plus optional ground fault (Code G).
What frame sizes does VM6EY cover?
VM6EY covers five frames: 250 A, 400 A, 630 A, 800 A, and 1250 A, all 0.4–1.0×In adjustable in 3P and 4P.
Can VM6EY perform remote opening and closing?
Yes. VM6EY supports four-remote control when paired with a P1 (DC3) or P2 (DC6) electric operating mechanism.
What is the short-time withstand current (Icw) of VM6EY?
VM6EY is a Class B MCCB rated at 10 kA/1s on 400–630 A frames and 20 kA/1s on 800–1250 A frames.
Are plug-in and draw-out kits compatible with VM6EY?
Yes. Plug-in front/back bases are supported from 250 A to 800 A (3P/4P), and draw-out back-panel bases are supported on 400, 630, and 800 A (3P).