VIOX Electric
Language

VIOX VM6 Series Thermomagnetic MCCB (125A–2000A)

VIOX VM6 Series Thermomagnetic Molded Case Circuit Breakers (MCCB) cover 8 industrial frame sizes from 125 A to 2000 A (10 A–2000 A rated current, 1P/2P/3P/4P) for AC 230 V / 400 V / 690 V distribution and motor protection. Compliant with IEC/EN 60947-2 and GB/T 14048.2 (Class A, Ui 1000 V, Uimp 8 kV), VM6 offers four short-circuit breaking tiers (C, S, M, H) up to 100 kA Icu / 85 kA Ics at 400 V AC, low-temperature-rise options (40 K / 50 K), and a complete ecosystem of internal (shunt, UVT, auxiliary, alarm) and external (motor operator, rotary handle, plug-in, draw-out, interlock) accessories.

VIOX VM6 Series Thermomagnetic Molded Case Circuit Breaker (125 A–2000 A)

Product Overview

The VIOX VM6 Series is a compact, low-temperature-rise thermomagnetic molded case circuit breaker (MCCB) platform engineered for industrial and commercial power distribution networks at AC 50/60 Hz, rated working voltage up to AC 690 V, and frame currents from 125 A to 2000 A. Built with a multiple contact-blade arc-quenching architecture and compliant with IEC/EN 60947-2 and GB/T 14048.2 (Selectivity Category A), VM6 protects feeders, transformers, and power equipment against overload, short-circuit, and undervoltage faults, with optional magnetic-only release configurations for motor protection.

Key Engineering Features

  • Complete 8-Frame Industrial Range: VM6-125, VM6-160, VM6-250, VM6-400, VM6-630, VM6-800, VM6-1250, and VM6-2000 covering rated currents from 10 A to 2000 A.
  • Four Breaking Capacity Tiers (C / S / M / H): Up to 100 kA Icu / 85 kA Ics at AC 400 V (VM6-2000H), 85 kA Icu / 65 kA Ics (VM6-800H & VM6-1250H), 65 kA Icu / 65 kA Ics (VM6-400H & VM6-630H), and 50 kA Icu / 50 kA Ics (VM6-125H & VM6-160H).
  • High Insulation & Impulse Withstand: Rated insulation voltage Ui = 1000 V and rated impulse withstand voltage Uimp = 8 kV across the entire series.
  • Low Temperature Rise & Compact Volume: Multiple contact-blade design minimizes contact resistance; optional low-temperature-rise variants V (50 K) and V1 (40 K) support high-density switchgear enclosures.
  • Flexible Release & 4P Neutral Options: Available in thermal-magnetic distribution release (code 3) or magnetic-only motor protection release (code 2), plus four 4-pole neutral configurations (Types A, B, C, and D).
  • Complete Accessory Ecosystem: Supports electric motor operators (DC3 / DC6), manual rotary handles, mechanical interlocking, front/back plug-in and draw-out bases, plus 20 factory internal accessory combinations (codes 08–78).

Technical Specifications Summary

Parameter Specification
Product Series VIOX VM6 Series Thermomagnetic MCCB
Applicable Standards IEC/EN 60947-2; GB/T 14048.2
Frame Current Range (Inm) 125 A, 160 A, 250 A, 400 A, 630 A, 800 A, 1250 A, 2000 A
Rated Current Range (In) 10 A – 2000 A
Number of Poles 1P, 2P, 3P, 4P (1P on VM6-125; 2P on VM6-125/160; 3P/4P across all frames)
Rated Working Voltage (Ue) AC 230 V / AC 400 V / AC 690 V
Rated Insulation Voltage (Ui) 1000 V
Rated Impulse Withstand Voltage (Uimp) 8 kV
Breaking Capacity Codes C (Basic), S (Standard), M (Moderate), H (High Breaking)
Maximum Icu / Ics (AC 400 V) Up to 100 kA Icu / 85 kA Ics (VM6-2000H)
Selectivity Category Class A
Overcurrent Release Type Thermomagnetic (Code 3: Power Distribution) / Magnetic-Only (Code 2: Motor Protection)
Low Temperature Rise Options Standard; Type V (50 K); Type V1 (40 K)
Installation & Wiring Methods Fixed Front-Panel, Back-Panel (Z1), Plug-in Split/Integrated (Z2Q/Z2H/Z3Q/Z3H), Draw-out (DF/DR, 400–800 A)

Model Nomenclature & Quick Selection Code

Example order code: VM6-160 M P1 / 4 3 00 2 A V / P Z In=100A. Specify each code block below when submitting a panel schedule or RFQ:

Code Segment Options & Engineering Meaning Selection Notes
Series Prefix VM6 — Thermomagnetic Molded Case Circuit Breaker IEC/EN 60947-2 Class A platform
Frame Current (Inm) 125, 160, 250, 400, 630, 800, 1250, 2000 A Select frame ≥ required rated current In
Breaking Capacity Code C (Basic) · S (Standard) · M (Moderate) · H (High Breaking) 400, 630, 800, 1250 (also S), and 2000 A frames primarily use M and H tiers
Operation Code Blank: Direct handle · P1: DC3 electric operator · P2: DC6 electric operator · ZY1 / ZF1: Center rotary handle (circular/square) · ZY2 / ZF2: Eccentric rotary handle · Z3: Integrated manual rotary handle (125/160/250 A only) 1P & 2P support direct handle only. Electric operator voltages: DC 24 V, DC 110 V, DC 220 V, AC 230 V (standard), AC 400 V
Poles Code 1 (1P) · 2 (2P) · 3 (3P) · 4 (4P) 125 A: 1P–4P · 160 A: 2P (C/S), 3P, 4P · 250–2000 A: 3P, 4P
Release Method 2: Magnetic-only release · 3: Thermal + magnetic release Use code 3 for distribution; code 2 for motor protection
Internal Accessory Code 00 (None) to 78 (Shunt, UVT, Auxiliary, Alarm combinations) 125 A 1P has no internal accessories; default lead length 500 mm (customizable); UVT uses terminal type
Usage Code Blank: Power distribution · 2: Motor protection ≤40 A: 8.5×In non-trip; 500 A action; 700–2000 A: power distribution only
4P Neutral Pole Type A: N unswitched, no overcurrent release · B: N switched with 3 poles, no overcurrent release · C: N switched + overcurrent release · D: N always connected + overcurrent release Specify for all 4-pole orders
Additional Function Blank: Standard · V: Low temperature rise 50 K · V1: Low temperature rise 40 K Ideal for high-ambient or compact switchboards
Installation & Wiring Blank: Front-panel fixed · P: Extension copper bar · Z1: Back-panel fixed · Z2Q / Z2H: Plug-in front/back split · Z3Q / Z3H: Plug-in front/back integrated · DF / DR: Draw-out front/back · K / JK / CK: Wiring box (full / incoming / outgoing) 1P/2P: connecting bars & back-panel only. Draw-out unavailable on 125–250 A. 1250/2000 A: connecting bars only
Protective Cover Blank: Standard · Z: Terminal cover Available for 3P (narrow/wide, short/long); unavailable on 125 A & 2000 A
Rated Current (In) 125 A frame: 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 A
160 A frame: 10, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 140, 160 A
250 A frame: 100, 125, 140, 160, 180, 200, 225, 250 A
400 A frame: 250, 315, 350, 400 A
630 A frame: 400, 500, 630 A
800 A frame: 500, 630, 700, 800 A
1250 A frame: 630, 700, 800, 1000, 1250 A
2000 A frame: 1000, 1250, 1600, 2000 A
Full industrial step coverage from 10 A to 2000 A

Main Electrical Performance — VM6-125 to VM6-630 Frames

All frames feature rated insulation voltage Ui = 1000 V, impulse withstand voltage Uimp = 8 kV, Selectivity Category Class A, and thermomagnetic overcurrent release.

Model & Tier Rated Current In (A) Poles Ue (AC) Ics (230 / 400 / 690 V) Icu (230 / 400 / 690 V)
VM6-125C 10–125 A 1P / 2P / 3P / 4P 230 / 400 / 690 V 5 / 5 / 3 kA 8 / 8 / 5 kA
VM6-125S 10–125 A 1P / 2P / 3P / 4P 230 / 400 / 690 V 15 / 13 (3P/4P) / 3 (3P/4P) kA 30 / 25 (3P/4P) / 6 (3P/4P) kA
VM6-125M 10–125 A 1P / 2P / 3P / 4P 230 (1P) / 400 / 690 V 35 (3P/4P) / 18 (1P/3P/4P) / 5 (3P/4P) kA 36 (1P) · 50 (3P/4P) / 36 / 10 (3P/4P) kA
VM6-125H 10–125 A 1P / 2P / 3P / 4P 230 (1P) / 400 / 690 V 50 / 50 / 8 kA 50 / 50 / 15 kA
VM6-160C 10–160 A 2P / 3P / 4P 230 / 400 / 690 V 7 / 10 / 2 kA 10 / 15 / 8 kA
VM6-160S 10–160 A 2P / 3P / 4P 230 / 400 / 690 V 10 / 13 / 3 kA 20 / 25 / 6 kA
VM6-160M 10–160 A 3P / 4P 230 / 400 / 690 V 25 / 18 / 5 kA 30 / 36 / 10 kA
VM6-160H 10–160 A 3P / 4P 230 / 400 / 690 V 35 / 35 (2P) · 50 (3P/4P) / 10 kA 50 / 50 / 15 kA
VM6-250C 100–250 A 3P / 4P 230 / 400 / 690 V 20 / 10 / 3 kA 30 / 15 / 5 kA
VM6-250S 100–250 A 3P / 4P 230 / 400 / 690 V 25 / 15 / 4 kA 50 / 30 / 8 kA
VM6-250M 100–250 A 3P / 4P 230 / 400 / 690 V 40 / 35 / 10 kA 65 / 50 / 15 kA
VM6-250H 100–250 A 3P / 4P 230 / 400 / 690 V 50 / 50 / 15 kA 70 / 65 / 20 kA
VM6-400S 250–400 A 3P / 4P 230 / 400 / 690 V 25 / 15 / 4 kA 50 / 30 / 8 kA
VM6-400M 250–400 A 3P / 4P 230 / 400 / 690 V 40 / 35 / 10 kA 65 / 50 / 20 kA
VM6-400H 250–400 A 3P / 4P 230 / 400 / 690 V 50 / 65 / 12 kA 70 / 65 / 25 kA
VM6-630M 400–630 A 3P / 4P 230 / 400 / 690 V 20 / 35 / 5 kA 30 / 50 / 10 kA
VM6-630H 400–630 A 3P / 4P 230 / 400 / 690 V 30 / 65 / 30 kA 50 / 65 / 20 kA

Main Electrical Performance — High-Current VM6-800 to VM6-2000 Frames

Model & Tier Rated Current In (A) Poles Ue (AC) Ics (230 / 400 / 690 V) Icu (230 / 400 / 690 V)
VM6-800M 500, 630, 700, 800 A 3P / 4P 230 / 400 / 690 V 65 / 50 / 15 kA 80 / 65 / 25 kA
VM6-800H 500, 630, 700, 800 A 3P / 4P 230 / 400 / 690 V 70 / 65 / 20 kA 85 / 85 / 35 kA
VM6-1250S 630, 700, 800, 1000, 1250 A 3P / 4P 240 / 400 / 690 V 40 / 35 / 10 kA 65 / 50 / 20 kA
VM6-1250M 630, 700, 800, 1000, 1250 A 3P / 4P 230 / 400 / 690 V 65 / 50 / 15 kA 80 / 65 / 25 kA
VM6-1250H 630, 700, 800, 1000, 1250 A 3P / 4P 230 / 400 / 690 V 70 / 65 / 20 kA 85 / 85 / 35 kA
VM6-2000M 1000, 1250, 1600, 2000 A 3P / 4P 400 / 690 V — / 50 / 20 kA — / 50 / 20 kA
VM6-2000H 1000, 1250, 1600, 2000 A 3P / 4P 400 / 690 V — / 85 / 20 kA — / 100 / 20 kA

Outline Dimensions (mm) — All 8 Frame Sizes

Height measured from the bottom of the base to the face cover and to the top of the operating handle.

Frame Poles Width W (mm) Length L (mm) Height to Cover (mm) Height to Handle (mm)
VM6-125 1P / 2P / 3P / 4P 25 / 50 / 75 / 100 130 68 94.5
VM6-160 2P / 3P / 4P 60 / 90 / 120 155 68 / 82 94 / 108
VM6-250 3P / 4P 105 / 140 165 68 / 88 96 / 116
VM6-400 3P / 4P 140 / 184 257 103 152
VM6-630 3P / 4P 140 / 184 257 103 152
VM6-800 3P / 4P 210 / 280 275.5 103 152
VM6-1250 3P / 4P 210 / 280 275.5 103 152
VM6-2000 3P / 4P 210 / 280 340 141 244

External Accessories Compatibility Matrix

External Accessory VM6-125 VM6-160 VM6-250 VM6-400 / 630 / 800 VM6-1250 / 2000
Electric Motor Operation 3P, 4P 3P, 4P 3P, 4P 3P, 4P 3P, 4P
Manual Rotary Operation 3P, 4P 3P, 4P 3P, 4P 3P, 4P 3P, 4P
Extension Copper Bar 1P, 2P, 3P, 4P 2P, 3P, 4P 3P, 4P 3P, 4P 3P, 4P
Mechanical Interlocking 3P, 4P 3P, 4P 3P, 4P 3P, 4P Not available
Plug-in Front-Panel (Split / Integrated / Fixed) 3P, 4P (Integrated/Fixed); 3P (Split) 3P, 4P 3P, 4P 3P, 4P Not available
Plug-in Back-Panel (Split / Integrated / Fixed) 3P, 4P (Integrated/Fixed); 3P (Split) 3P, 4P 3P, 4P 3P, 4P Not available
Draw-out Back-Panel Type Not available Not available Not available 3P only Not available

Internal Accessories & Factory Installation Codes (00–78)

Shunt and undervoltage release control voltages: DC 24 V, DC 110 V, DC 220 V, AC 230 V (standard), AC 400 V. Note: For Code 50 (Shunt + Undervoltage), VM6-125 and VM6-160 require customized left-side undervoltage release; VM6-250 requires customized left-side shunt release.

Accessory Code Internal Accessory Configuration Supported Frames & Poles
00 None (Standard breaker without internal accessories) All frames (1P–4P)
08 Alarm contact VM6-125 to VM6-2000 (3P, 4P)
10 Shunt release VM6-125/160 (2P, 3P, 4P); VM6-250 to 2000 (3P, 4P)
18 Shunt release + Alarm contact VM6-125 to VM6-2000 (3P, 4P)
20 Single auxiliary contact (1 set changeover) VM6-125/160 (2P, 3P, 4P); VM6-250 to 2000 (3P, 4P)
27 Dual auxiliary contacts (2 sets changeover) VM6-125/160 (2P, 3P, 4P); VM6-250 to 2000 (3P, 4P)
28 Single auxiliary contact + Alarm contact VM6-125 to VM6-2000 (3P, 4P)
29 Dual auxiliary contacts + Alarm contact VM6-125 to VM6-2000 (3P, 4P)
30 Undervoltage release (UVT) VM6-125/160 (2P, 3P, 4P); VM6-250 to 2000 (3P, 4P)
38 Undervoltage release + Alarm contact VM6-125 to VM6-2000 (3P, 4P)
40 Shunt release + Single auxiliary contact VM6-125 to VM6-2000 (3P, 4P)
41 Shunt release + Dual auxiliary contacts VM6-125 to VM6-2000 (3P, 4P)
48 Shunt release + Auxiliary + Alarm contact VM6-125 to VM6-2000 (3P, 4P)
50 Shunt release + Undervoltage release VM6-125 to VM6-2000 (3P, 4P; see Note above)
60 Two sets of single auxiliary contacts VM6-125 to VM6-2000 (3P, 4P)
61 Single auxiliary contact + Dual auxiliary contacts VM6-125 to VM6-2000 (3P, 4P)
62 Two sets of dual auxiliary contacts VM6-125 to VM6-2000 (3P, 4P)
68 Single auxiliary contact + Auxiliary + Alarm contact VM6-125 to VM6-2000 (3P, 4P)
69 Dual auxiliary contacts + Auxiliary + Alarm contact VM6-125 to VM6-2000 (3P, 4P)
70 Undervoltage release + Single auxiliary contact VM6-125 to VM6-2000 (3P, 4P)
71 Undervoltage release + Dual auxiliary contacts VM6-125 to VM6-2000 (3P, 4P)
78 Undervoltage release + Auxiliary + Alarm contact VM6-125 to VM6-2000 (3P, 4P)

Applications & Engineering Support

The VIOX VM6 Series is suited for main incoming switchgear, commercial sub-distribution boards, transformer feeders, generator panels, HVAC & pump motor control centers, and industrial OEM switchboards. Explore the full VIOX MCCB range, coordinate downstream protection with VIOX MCBs and RCBOs, or send your panel schedule for matched factory pricing and CAD drawings.

Need a Product Quote?
Let’s Build It Together.

Send us the product model, technical ratings, quantity, and OEM requirements. Our team will review your application and respond within one business day.

Request a Quote